Cargando…
Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments
BACKGROUND: Some porous materials have been developed to enhance biologic fusion of the implants to bone in spine fusion surgeries. However, there are several inherent limitations. In this study, a novel biomedical porous tantalum was applied to in vitro and in vivo experiments to test its biocompat...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629310/ https://www.ncbi.nlm.nih.gov/pubmed/30628959 http://dx.doi.org/10.1097/CM9.0000000000000030 |
_version_ | 1783435083550556160 |
---|---|
author | Lu, Ming Xu, Song Lei, Zi-Xiong Lu, Dong Cao, Wei Huttula, Marko Hou, Chang-He Du, Shao-Hua Chen, Wei Dai, Shuang-Wu Li, Hao-Miao Jin, Da-Di |
author_facet | Lu, Ming Xu, Song Lei, Zi-Xiong Lu, Dong Cao, Wei Huttula, Marko Hou, Chang-He Du, Shao-Hua Chen, Wei Dai, Shuang-Wu Li, Hao-Miao Jin, Da-Di |
author_sort | Lu, Ming |
collection | PubMed |
description | BACKGROUND: Some porous materials have been developed to enhance biologic fusion of the implants to bone in spine fusion surgeries. However, there are several inherent limitations. In this study, a novel biomedical porous tantalum was applied to in vitro and in vivo experiments to test its biocompatibility and osteocompatibility. METHODS: Bone marrow-derived mesenchymal stem cells (BMSCs) were cultured on porous tantalum implant. Scanning electron microscope (SEM) and Cell Counting Kit-8 assay were used to evaluate the cell toxicity and biocompatibility. Twenty-four rabbits were performed discectomy only (control group), discectomy with autologous bone implanted (autograft group), and discectomy with porous tantalum implanted (tantalum group) at 3 levels: L3–L4, L4–L5, and L5–L6 in random order. All the 24 rabbits were randomly sacrificed at the different post-operative times (2, 4, 6, and 12 months; n = 6 at each time point). Histologic examination and micro-computed tomography scans were done to evaluate the fusion process. Comparison of fusion index scores between groups was analyzed using one-way analysis of variance. Other comparisons of numerical variables between groups were made by Student t test. RESULTS: All rabbits survived and recovered without any symptoms of nerve injury. Radiographic fusion index scores at 12 months post-operatively between autograft and tantalum groups showed no significant difference (2.89 ± 0.32 vs. 2.83 ± 0.38, F = 244.60, P = 0.709). Cell Counting Kit-8 assay showed no significant difference of absorbance values between the leaching liquor group and control group (1.25 ± 0.06 vs. 1.23 ± 0.04, t = –0.644, P = 0.545), which indicated the BMSC proliferation without toxicity. SEM images showed that these cells had irregular shapes with long spindles adhered to the surface of tantalum implant. No implant degradation, wear debris, or osteolysis was observed. Histologic results showed solid fusion in the porous tantalum and autologous bone implanted intervertebral spaces. CONCLUSION: This novel porous tantalum implant showed a good biocompatibility and osteocompatibility, which could be a valid biomaterial for interbody fusion cages. |
format | Online Article Text |
id | pubmed-6629310 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-66293102019-07-22 Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments Lu, Ming Xu, Song Lei, Zi-Xiong Lu, Dong Cao, Wei Huttula, Marko Hou, Chang-He Du, Shao-Hua Chen, Wei Dai, Shuang-Wu Li, Hao-Miao Jin, Da-Di Chin Med J (Engl) Original Articles BACKGROUND: Some porous materials have been developed to enhance biologic fusion of the implants to bone in spine fusion surgeries. However, there are several inherent limitations. In this study, a novel biomedical porous tantalum was applied to in vitro and in vivo experiments to test its biocompatibility and osteocompatibility. METHODS: Bone marrow-derived mesenchymal stem cells (BMSCs) were cultured on porous tantalum implant. Scanning electron microscope (SEM) and Cell Counting Kit-8 assay were used to evaluate the cell toxicity and biocompatibility. Twenty-four rabbits were performed discectomy only (control group), discectomy with autologous bone implanted (autograft group), and discectomy with porous tantalum implanted (tantalum group) at 3 levels: L3–L4, L4–L5, and L5–L6 in random order. All the 24 rabbits were randomly sacrificed at the different post-operative times (2, 4, 6, and 12 months; n = 6 at each time point). Histologic examination and micro-computed tomography scans were done to evaluate the fusion process. Comparison of fusion index scores between groups was analyzed using one-way analysis of variance. Other comparisons of numerical variables between groups were made by Student t test. RESULTS: All rabbits survived and recovered without any symptoms of nerve injury. Radiographic fusion index scores at 12 months post-operatively between autograft and tantalum groups showed no significant difference (2.89 ± 0.32 vs. 2.83 ± 0.38, F = 244.60, P = 0.709). Cell Counting Kit-8 assay showed no significant difference of absorbance values between the leaching liquor group and control group (1.25 ± 0.06 vs. 1.23 ± 0.04, t = –0.644, P = 0.545), which indicated the BMSC proliferation without toxicity. SEM images showed that these cells had irregular shapes with long spindles adhered to the surface of tantalum implant. No implant degradation, wear debris, or osteolysis was observed. Histologic results showed solid fusion in the porous tantalum and autologous bone implanted intervertebral spaces. CONCLUSION: This novel porous tantalum implant showed a good biocompatibility and osteocompatibility, which could be a valid biomaterial for interbody fusion cages. Wolters Kluwer Health 2019-01-05 2019-01-05 /pmc/articles/PMC6629310/ /pubmed/30628959 http://dx.doi.org/10.1097/CM9.0000000000000030 Text en Copyright © 2018 The Chinese Medical Association, produced by Wolters Kluwer, Inc. under the CC-BY-NC-ND license. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0 |
spellingShingle | Original Articles Lu, Ming Xu, Song Lei, Zi-Xiong Lu, Dong Cao, Wei Huttula, Marko Hou, Chang-He Du, Shao-Hua Chen, Wei Dai, Shuang-Wu Li, Hao-Miao Jin, Da-Di Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments |
title | Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments |
title_full | Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments |
title_fullStr | Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments |
title_full_unstemmed | Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments |
title_short | Application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments |
title_sort | application of a novel porous tantalum implant in rabbit anterior lumbar spine fusion model: in vitro and in vivo experiments |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6629310/ https://www.ncbi.nlm.nih.gov/pubmed/30628959 http://dx.doi.org/10.1097/CM9.0000000000000030 |
work_keys_str_mv | AT luming applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT xusong applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT leizixiong applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT ludong applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT caowei applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT huttulamarko applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT houchanghe applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT dushaohua applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT chenwei applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT daishuangwu applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT lihaomiao applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments AT jindadi applicationofanovelporoustantalumimplantinrabbitanteriorlumbarspinefusionmodelinvitroandinvivoexperiments |