Cargando…

Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis

Protection of intrinsically brittle quartz chromatographic columns (CCs) from breakage or property deterioration in gas chromatography (GC) analysis has become an important research topic regarding high-temperature GC techniques. Polyimide (PI) has proved to be the most suitable protective coating f...

Descripción completa

Detalles Bibliográficos
Autores principales: Huangfu, Meng-ge, Zhang, Yan, Zhang, Xin-ling, Liu, Jin-gang, Liu, Ying-cong, Guo, Yi-dan, Huang, Qing-yuan, Zhang, Xiu-min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6630507/
https://www.ncbi.nlm.nih.gov/pubmed/31159362
http://dx.doi.org/10.3390/polym11060946
_version_ 1783435318249127936
author Huangfu, Meng-ge
Zhang, Yan
Zhang, Xin-ling
Liu, Jin-gang
Liu, Ying-cong
Guo, Yi-dan
Huang, Qing-yuan
Zhang, Xiu-min
author_facet Huangfu, Meng-ge
Zhang, Yan
Zhang, Xin-ling
Liu, Jin-gang
Liu, Ying-cong
Guo, Yi-dan
Huang, Qing-yuan
Zhang, Xiu-min
author_sort Huangfu, Meng-ge
collection PubMed
description Protection of intrinsically brittle quartz chromatographic columns (CCs) from breakage or property deterioration in gas chromatography (GC) analysis has become an important research topic regarding high-temperature GC techniques. Polyimide (PI) has proved to be the most suitable protective coating for quartz CCs. In the current research, a series of novel high-temperature-resistant PI coatings for quartz CCs operated over 320 °C have been successfully prepared. For this purpose, the aromatic diamine with a rigid skeleton structure 2-(4-aminophenyl)-5-aminobenzimidazole (APBI) was copolymerized with two aromatic dianhydrides—3,3’,4,4’-benzophenotetracarboxylic acid dianhydride (BTDA) and 4,4’-oxydiphthalic anhydride (ODPA)—and an aromatic diamine with flexible ether linkages—4,4’-oxydianiline (ODA)—by a two-step polymerization procedure via soluble poly(amic acid) (PAA) precursors, followed by thermal imidization at elevated temperatures. The developed PI coatings exhibited good comprehensive properties, including glass transition temperatures (T(g)) as high as 346.9 °C, measured by dynamic mechanical analysis (DMA), and coefficients of linear thermal expansion (CTEs) as low as 24.6 × 10(−6)/K in the range of 50–300 °C. In addition, the PI coatings exhibited good adhesion to the fused quartz capillary columns. No cracking, delamination, warpage, or other failures occurred during the 100-cycle thermal shock test in the range of 25–320 °C.
format Online
Article
Text
id pubmed-6630507
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66305072019-08-19 Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis Huangfu, Meng-ge Zhang, Yan Zhang, Xin-ling Liu, Jin-gang Liu, Ying-cong Guo, Yi-dan Huang, Qing-yuan Zhang, Xiu-min Polymers (Basel) Article Protection of intrinsically brittle quartz chromatographic columns (CCs) from breakage or property deterioration in gas chromatography (GC) analysis has become an important research topic regarding high-temperature GC techniques. Polyimide (PI) has proved to be the most suitable protective coating for quartz CCs. In the current research, a series of novel high-temperature-resistant PI coatings for quartz CCs operated over 320 °C have been successfully prepared. For this purpose, the aromatic diamine with a rigid skeleton structure 2-(4-aminophenyl)-5-aminobenzimidazole (APBI) was copolymerized with two aromatic dianhydrides—3,3’,4,4’-benzophenotetracarboxylic acid dianhydride (BTDA) and 4,4’-oxydiphthalic anhydride (ODPA)—and an aromatic diamine with flexible ether linkages—4,4’-oxydianiline (ODA)—by a two-step polymerization procedure via soluble poly(amic acid) (PAA) precursors, followed by thermal imidization at elevated temperatures. The developed PI coatings exhibited good comprehensive properties, including glass transition temperatures (T(g)) as high as 346.9 °C, measured by dynamic mechanical analysis (DMA), and coefficients of linear thermal expansion (CTEs) as low as 24.6 × 10(−6)/K in the range of 50–300 °C. In addition, the PI coatings exhibited good adhesion to the fused quartz capillary columns. No cracking, delamination, warpage, or other failures occurred during the 100-cycle thermal shock test in the range of 25–320 °C. MDPI 2019-06-01 /pmc/articles/PMC6630507/ /pubmed/31159362 http://dx.doi.org/10.3390/polym11060946 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Huangfu, Meng-ge
Zhang, Yan
Zhang, Xin-ling
Liu, Jin-gang
Liu, Ying-cong
Guo, Yi-dan
Huang, Qing-yuan
Zhang, Xiu-min
Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis
title Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis
title_full Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis
title_fullStr Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis
title_full_unstemmed Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis
title_short Preparation and Thermal Evaluation of Novel Polyimide Protective Coatings for Quartz Capillary Chromatographic Columns Operated over 320 °C for High-Temperature Gas Chromatography Analysis
title_sort preparation and thermal evaluation of novel polyimide protective coatings for quartz capillary chromatographic columns operated over 320 °c for high-temperature gas chromatography analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6630507/
https://www.ncbi.nlm.nih.gov/pubmed/31159362
http://dx.doi.org/10.3390/polym11060946
work_keys_str_mv AT huangfumengge preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis
AT zhangyan preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis
AT zhangxinling preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis
AT liujingang preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis
AT liuyingcong preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis
AT guoyidan preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis
AT huangqingyuan preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis
AT zhangxiumin preparationandthermalevaluationofnovelpolyimideprotectivecoatingsforquartzcapillarychromatographiccolumnsoperatedover320cforhightemperaturegaschromatographyanalysis