Cargando…

Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers

Charge-coupled device (CCD) spectrometers are widely used as detectors in analytical laboratory instruments and as sensors for in situ optical measurements. However, as the applications become more complex, the physical and electronic limits of the CCD spectrometers may restrict their applicability....

Descripción completa

Detalles Bibliográficos
Autores principales: Nehir, Münevver, Frank, Carsten, Aßmann, Steffen, Achterberg, Eric P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6630795/
https://www.ncbi.nlm.nih.gov/pubmed/31242659
http://dx.doi.org/10.3390/s19122833
_version_ 1783435386596360192
author Nehir, Münevver
Frank, Carsten
Aßmann, Steffen
Achterberg, Eric P.
author_facet Nehir, Münevver
Frank, Carsten
Aßmann, Steffen
Achterberg, Eric P.
author_sort Nehir, Münevver
collection PubMed
description Charge-coupled device (CCD) spectrometers are widely used as detectors in analytical laboratory instruments and as sensors for in situ optical measurements. However, as the applications become more complex, the physical and electronic limits of the CCD spectrometers may restrict their applicability. The errors due to dark currents, temperature variations, and blooming can be readily corrected. However, a correction for uncertainty of integration time and wavelength calibration is typically lacking in most devices, and detector non-linearity may distort the signal by up to 5% for some measurements. Here, we propose a simple correction method to compensate for non-linearity errors in optical measurements where compact CCD spectrometers are used. The results indicate that the error due to the non-linearity of a spectrometer can be reduced from several hundred counts to about 40 counts if the proposed correction function is applied.
format Online
Article
Text
id pubmed-6630795
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66307952019-08-19 Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers Nehir, Münevver Frank, Carsten Aßmann, Steffen Achterberg, Eric P. Sensors (Basel) Article Charge-coupled device (CCD) spectrometers are widely used as detectors in analytical laboratory instruments and as sensors for in situ optical measurements. However, as the applications become more complex, the physical and electronic limits of the CCD spectrometers may restrict their applicability. The errors due to dark currents, temperature variations, and blooming can be readily corrected. However, a correction for uncertainty of integration time and wavelength calibration is typically lacking in most devices, and detector non-linearity may distort the signal by up to 5% for some measurements. Here, we propose a simple correction method to compensate for non-linearity errors in optical measurements where compact CCD spectrometers are used. The results indicate that the error due to the non-linearity of a spectrometer can be reduced from several hundred counts to about 40 counts if the proposed correction function is applied. MDPI 2019-06-25 /pmc/articles/PMC6630795/ /pubmed/31242659 http://dx.doi.org/10.3390/s19122833 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Nehir, Münevver
Frank, Carsten
Aßmann, Steffen
Achterberg, Eric P.
Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers
title Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers
title_full Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers
title_fullStr Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers
title_full_unstemmed Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers
title_short Improving Optical Measurements: Non-Linearity Compensation of Compact Charge-Coupled Device (CCD) Spectrometers
title_sort improving optical measurements: non-linearity compensation of compact charge-coupled device (ccd) spectrometers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6630795/
https://www.ncbi.nlm.nih.gov/pubmed/31242659
http://dx.doi.org/10.3390/s19122833
work_keys_str_mv AT nehirmunevver improvingopticalmeasurementsnonlinearitycompensationofcompactchargecoupleddeviceccdspectrometers
AT frankcarsten improvingopticalmeasurementsnonlinearitycompensationofcompactchargecoupleddeviceccdspectrometers
AT aßmannsteffen improvingopticalmeasurementsnonlinearitycompensationofcompactchargecoupleddeviceccdspectrometers
AT achterbergericp improvingopticalmeasurementsnonlinearitycompensationofcompactchargecoupleddeviceccdspectrometers