Cargando…

Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial

Purpose: To compare virtual planning accuracy of novel computer-assisted, template-based implant placement techniques, which make use of CAD/CAM stereolithographic surgical templates with or without metallic sleeves. Furthermore, to compare open versus closed sleeves for templates without metallic s...

Descripción completa

Detalles Bibliográficos
Autores principales: Tallarico, Marco, Martinolli, Matteo, Kim, Yong-Jin, Cocchi, Fabio, Meloni, Silvio Mario, Alushi, Adem, Xhanari, Erta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6631019/
https://www.ncbi.nlm.nih.gov/pubmed/30987037
http://dx.doi.org/10.3390/dj7020041
_version_ 1783435432429617152
author Tallarico, Marco
Martinolli, Matteo
Kim, Yong-Jin
Cocchi, Fabio
Meloni, Silvio Mario
Alushi, Adem
Xhanari, Erta
author_facet Tallarico, Marco
Martinolli, Matteo
Kim, Yong-Jin
Cocchi, Fabio
Meloni, Silvio Mario
Alushi, Adem
Xhanari, Erta
author_sort Tallarico, Marco
collection PubMed
description Purpose: To compare virtual planning accuracy of novel computer-assisted, template-based implant placement techniques, which make use of CAD/CAM stereolithographic surgical templates with or without metallic sleeves. Furthermore, to compare open versus closed sleeves for templates without metallic sleeves. Materials and methods: Any partially edentulous patients requiring at least one implant to be placed according to a computer-assisted template-based protocol were enrolled. Patients were randomized according to a parallel group design into two arms: Surgical template with or without metallic sleeves. Three deviation parameters (angular, horizontal, vertical) were defined to evaluate the discrepancy between the planned and placed implant positions. Results: No implants failed, and no complications were experienced. Forty-one implants were placed using surgical templates with metallic sleeves while 49 implants were placed with a surgical template without metallic sleeves. Of these, 16 implants were placed through open sleeves and 33 through closed sleeves. There was a statistically significant difference in angle (p = 0.0212) and in the vertical plan (p = 0.0073) with lower values for implants placed with a surgical template without metallic sleeves. In the test group, close sleeves were more accurate compared with open sleeves in angle (p = 0.0268) and in horizontal plan (p = 0.0477). Conclusion: With the limitations of the present study, surgical templates without metallic sleeves were more accurate in the vertical plan and angle compared to the conventional template with metallic sleeves. Open sleeves should be used with caution in the molar region only in case of reduced interarch space. Further research is needed to confirm these preliminary results.
format Online
Article
Text
id pubmed-6631019
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66310192019-08-19 Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial Tallarico, Marco Martinolli, Matteo Kim, Yong-Jin Cocchi, Fabio Meloni, Silvio Mario Alushi, Adem Xhanari, Erta Dent J (Basel) Article Purpose: To compare virtual planning accuracy of novel computer-assisted, template-based implant placement techniques, which make use of CAD/CAM stereolithographic surgical templates with or without metallic sleeves. Furthermore, to compare open versus closed sleeves for templates without metallic sleeves. Materials and methods: Any partially edentulous patients requiring at least one implant to be placed according to a computer-assisted template-based protocol were enrolled. Patients were randomized according to a parallel group design into two arms: Surgical template with or without metallic sleeves. Three deviation parameters (angular, horizontal, vertical) were defined to evaluate the discrepancy between the planned and placed implant positions. Results: No implants failed, and no complications were experienced. Forty-one implants were placed using surgical templates with metallic sleeves while 49 implants were placed with a surgical template without metallic sleeves. Of these, 16 implants were placed through open sleeves and 33 through closed sleeves. There was a statistically significant difference in angle (p = 0.0212) and in the vertical plan (p = 0.0073) with lower values for implants placed with a surgical template without metallic sleeves. In the test group, close sleeves were more accurate compared with open sleeves in angle (p = 0.0268) and in horizontal plan (p = 0.0477). Conclusion: With the limitations of the present study, surgical templates without metallic sleeves were more accurate in the vertical plan and angle compared to the conventional template with metallic sleeves. Open sleeves should be used with caution in the molar region only in case of reduced interarch space. Further research is needed to confirm these preliminary results. MDPI 2019-04-02 /pmc/articles/PMC6631019/ /pubmed/30987037 http://dx.doi.org/10.3390/dj7020041 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tallarico, Marco
Martinolli, Matteo
Kim, Yong-Jin
Cocchi, Fabio
Meloni, Silvio Mario
Alushi, Adem
Xhanari, Erta
Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial
title Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial
title_full Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial
title_fullStr Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial
title_full_unstemmed Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial
title_short Accuracy of Computer-Assisted Template-Based Implant Placement Using Two Different Surgical Templates Designed with or without Metallic Sleeves: A Randomized Controlled Trial
title_sort accuracy of computer-assisted template-based implant placement using two different surgical templates designed with or without metallic sleeves: a randomized controlled trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6631019/
https://www.ncbi.nlm.nih.gov/pubmed/30987037
http://dx.doi.org/10.3390/dj7020041
work_keys_str_mv AT tallaricomarco accuracyofcomputerassistedtemplatebasedimplantplacementusingtwodifferentsurgicaltemplatesdesignedwithorwithoutmetallicsleevesarandomizedcontrolledtrial
AT martinollimatteo accuracyofcomputerassistedtemplatebasedimplantplacementusingtwodifferentsurgicaltemplatesdesignedwithorwithoutmetallicsleevesarandomizedcontrolledtrial
AT kimyongjin accuracyofcomputerassistedtemplatebasedimplantplacementusingtwodifferentsurgicaltemplatesdesignedwithorwithoutmetallicsleevesarandomizedcontrolledtrial
AT cocchifabio accuracyofcomputerassistedtemplatebasedimplantplacementusingtwodifferentsurgicaltemplatesdesignedwithorwithoutmetallicsleevesarandomizedcontrolledtrial
AT melonisilviomario accuracyofcomputerassistedtemplatebasedimplantplacementusingtwodifferentsurgicaltemplatesdesignedwithorwithoutmetallicsleevesarandomizedcontrolledtrial
AT alushiadem accuracyofcomputerassistedtemplatebasedimplantplacementusingtwodifferentsurgicaltemplatesdesignedwithorwithoutmetallicsleevesarandomizedcontrolledtrial
AT xhanarierta accuracyofcomputerassistedtemplatebasedimplantplacementusingtwodifferentsurgicaltemplatesdesignedwithorwithoutmetallicsleevesarandomizedcontrolledtrial