The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion

BACKGROUND: The RITMIA™ app (Heart Sentinel™, Parma, Italy) is a novel application that combined with a wearable consumer-grade chest-strap Bluetooth heart rate monitor, provides automated detection of atrial fibrillation (AF), and may be promising for sustainable AF screening programs, since it is...

Descripción completa

Detalles Bibliográficos
Autores principales: Reverberi, Claudio, Rabia, Granit, De Rosa, Fabrizio, Bosi, Davide, Botti, Andrea, Benatti, Giorgio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6634013/
https://www.ncbi.nlm.nih.gov/pubmed/31355264
http://dx.doi.org/10.1155/2019/4861951
_version_ 1783435741468033024
author Reverberi, Claudio
Rabia, Granit
De Rosa, Fabrizio
Bosi, Davide
Botti, Andrea
Benatti, Giorgio
author_facet Reverberi, Claudio
Rabia, Granit
De Rosa, Fabrizio
Bosi, Davide
Botti, Andrea
Benatti, Giorgio
author_sort Reverberi, Claudio
collection PubMed
description BACKGROUND: The RITMIA™ app (Heart Sentinel™, Parma, Italy) is a novel application that combined with a wearable consumer-grade chest-strap Bluetooth heart rate monitor, provides automated detection of atrial fibrillation (AF), and may be promising for sustainable AF screening programs, since it is known that prolonged monitoring leads to increased AF diagnosis. OBJECTIVE: The purpose of this study was to examine whether RITMIA™ could accurately differentiate sinus rhythm (SR) from AF compared with gold-standard physician-interpreted 12-lead electrocardiogram (ECG). DESIGN: In this observational prospective study consecutive patients presenting for elective cardioversion (ECV) of AF, from November 2017 to November 2018, were enrolled. Patients underwent paired 12-lead ECG and RITMIA™ recording, both before and after ECV procedure. The RITMIA™ automated interpretation was compared with 12-lead ECG interpreted by the agreement of two cardiologists. The latter were blinded to the results of the App automated diagnosis. Feasibility, sensitivity, specificity, and K coefficient for RITMIA™ automated diagnosis were calculated. RESULTS: A total of 100 consecutive patients were screened and enrolled. Five patients did not undergo ECV due to spontaneous restoration of SR. 95 patients who actually underwent ECV were included in the final analysis. Mean age was 66.2±10.7 years; female patients were 20 (21.1%). There were 190 paired ECGs and RITMIA™ recordings. The RITMIA™ app correctly detected AF with 97% sensitivity, 95.6% specificity, and a K coefficient of 0.93. CONCLUSIONS: The automated RITMIA™ algorithm very accurately differentiated AF from SR before and after elective ECV. The only hardware required by this method is a cheap consumer-grade Bluetooth heart rate monitor of the chest-strap type. This robust and affordable RITMIA™ technology could be used to conduct population-wide screening in patients at risk for silent AF, thanks to the long-term monitoring applicability.
format Online
Article
Text
id pubmed-6634013
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-66340132019-07-28 The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion Reverberi, Claudio Rabia, Granit De Rosa, Fabrizio Bosi, Davide Botti, Andrea Benatti, Giorgio Biomed Res Int Research Article BACKGROUND: The RITMIA™ app (Heart Sentinel™, Parma, Italy) is a novel application that combined with a wearable consumer-grade chest-strap Bluetooth heart rate monitor, provides automated detection of atrial fibrillation (AF), and may be promising for sustainable AF screening programs, since it is known that prolonged monitoring leads to increased AF diagnosis. OBJECTIVE: The purpose of this study was to examine whether RITMIA™ could accurately differentiate sinus rhythm (SR) from AF compared with gold-standard physician-interpreted 12-lead electrocardiogram (ECG). DESIGN: In this observational prospective study consecutive patients presenting for elective cardioversion (ECV) of AF, from November 2017 to November 2018, were enrolled. Patients underwent paired 12-lead ECG and RITMIA™ recording, both before and after ECV procedure. The RITMIA™ automated interpretation was compared with 12-lead ECG interpreted by the agreement of two cardiologists. The latter were blinded to the results of the App automated diagnosis. Feasibility, sensitivity, specificity, and K coefficient for RITMIA™ automated diagnosis were calculated. RESULTS: A total of 100 consecutive patients were screened and enrolled. Five patients did not undergo ECV due to spontaneous restoration of SR. 95 patients who actually underwent ECV were included in the final analysis. Mean age was 66.2±10.7 years; female patients were 20 (21.1%). There were 190 paired ECGs and RITMIA™ recordings. The RITMIA™ app correctly detected AF with 97% sensitivity, 95.6% specificity, and a K coefficient of 0.93. CONCLUSIONS: The automated RITMIA™ algorithm very accurately differentiated AF from SR before and after elective ECV. The only hardware required by this method is a cheap consumer-grade Bluetooth heart rate monitor of the chest-strap type. This robust and affordable RITMIA™ technology could be used to conduct population-wide screening in patients at risk for silent AF, thanks to the long-term monitoring applicability. Hindawi 2019-07-02 /pmc/articles/PMC6634013/ /pubmed/31355264 http://dx.doi.org/10.1155/2019/4861951 Text en Copyright © 2019 Claudio Reverberi et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Reverberi, Claudio
Rabia, Granit
De Rosa, Fabrizio
Bosi, Davide
Botti, Andrea
Benatti, Giorgio
The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
title The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
title_full The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
title_fullStr The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
title_full_unstemmed The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
title_short The RITMIA™ Smartphone App for Automated Detection of Atrial Fibrillation: Accuracy in Consecutive Patients Undergoing Elective Electrical Cardioversion
title_sort ritmia™ smartphone app for automated detection of atrial fibrillation: accuracy in consecutive patients undergoing elective electrical cardioversion
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6634013/
https://www.ncbi.nlm.nih.gov/pubmed/31355264
http://dx.doi.org/10.1155/2019/4861951
work_keys_str_mv AT reverbericlaudio theritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT rabiagranit theritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT derosafabrizio theritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT bosidavide theritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT bottiandrea theritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT benattigiorgio theritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT reverbericlaudio ritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT rabiagranit ritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT derosafabrizio ritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT bosidavide ritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT bottiandrea ritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion
AT benattigiorgio ritmiasmartphoneappforautomateddetectionofatrialfibrillationaccuracyinconsecutivepatientsundergoingelectiveelectricalcardioversion