Cargando…

Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement

The vast majority of P300-based brain-computer interface (BCI) systems are based on the well-known P300 speller presented by Farwell and Donchin for communication purposes and an alternative to people with neuromuscular disabilities, such as impaired eye movement. The purpose of the present work is...

Descripción completa

Detalles Bibliográficos
Autores principales: Ron-Angevin, R., Garcia, L., Fernández-Rodríguez, Á., Saracco, J., André, J. M., Lespinet-Najib, V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6636581/
https://www.ncbi.nlm.nih.gov/pubmed/31354802
http://dx.doi.org/10.1155/2019/7876248
_version_ 1783436089906692096
author Ron-Angevin, R.
Garcia, L.
Fernández-Rodríguez, Á.
Saracco, J.
André, J. M.
Lespinet-Najib, V.
author_facet Ron-Angevin, R.
Garcia, L.
Fernández-Rodríguez, Á.
Saracco, J.
André, J. M.
Lespinet-Najib, V.
author_sort Ron-Angevin, R.
collection PubMed
description The vast majority of P300-based brain-computer interface (BCI) systems are based on the well-known P300 speller presented by Farwell and Donchin for communication purposes and an alternative to people with neuromuscular disabilities, such as impaired eye movement. The purpose of the present work is to study the effect of speller size on P300-based BCI usability, measured in terms of effectiveness, efficiency, and satisfaction under overt and covert attention conditions. To this end, twelve participants used three speller sizes under both attentional conditions to spell 12 symbols. The results indicated that the speller size had, in both attentional conditions, a significant influence on performance. In both conditions (covert and overt), the best performances were obtained with the small and medium speller sizes, both being the most effective. The speller size did not significantly affect workload on the three speller sizes. In contrast, covert attention condition produced very high workload due to the increased resources expended to complete the task. Regarding users' preferences, significant differences were obtained between speller sizes. The small speller size was considered as the most complex, the most stressful, the less comfortable, and the most tiring. The medium speller size was always considered in the medium rank, which is the speller size that was evaluated less frequently and, for each dimension, the worst one. In this sense, the medium and the large speller sizes were considered as the most satisfactory. Finally, the medium speller size was the one to which the three standard dimensions were collected: high effectiveness, high efficiency, and high satisfaction. This work demonstrates that the speller size is an important parameter to consider in improving the usability of P300 BCI for communication purposes. The obtained results showed that using the proposed medium speller size, performance and satisfaction could be improved.
format Online
Article
Text
id pubmed-6636581
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-66365812019-07-28 Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement Ron-Angevin, R. Garcia, L. Fernández-Rodríguez, Á. Saracco, J. André, J. M. Lespinet-Najib, V. Comput Intell Neurosci Research Article The vast majority of P300-based brain-computer interface (BCI) systems are based on the well-known P300 speller presented by Farwell and Donchin for communication purposes and an alternative to people with neuromuscular disabilities, such as impaired eye movement. The purpose of the present work is to study the effect of speller size on P300-based BCI usability, measured in terms of effectiveness, efficiency, and satisfaction under overt and covert attention conditions. To this end, twelve participants used three speller sizes under both attentional conditions to spell 12 symbols. The results indicated that the speller size had, in both attentional conditions, a significant influence on performance. In both conditions (covert and overt), the best performances were obtained with the small and medium speller sizes, both being the most effective. The speller size did not significantly affect workload on the three speller sizes. In contrast, covert attention condition produced very high workload due to the increased resources expended to complete the task. Regarding users' preferences, significant differences were obtained between speller sizes. The small speller size was considered as the most complex, the most stressful, the less comfortable, and the most tiring. The medium speller size was always considered in the medium rank, which is the speller size that was evaluated less frequently and, for each dimension, the worst one. In this sense, the medium and the large speller sizes were considered as the most satisfactory. Finally, the medium speller size was the one to which the three standard dimensions were collected: high effectiveness, high efficiency, and high satisfaction. This work demonstrates that the speller size is an important parameter to consider in improving the usability of P300 BCI for communication purposes. The obtained results showed that using the proposed medium speller size, performance and satisfaction could be improved. Hindawi 2019-07-01 /pmc/articles/PMC6636581/ /pubmed/31354802 http://dx.doi.org/10.1155/2019/7876248 Text en Copyright © 2019 R. Ron-Angevin et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ron-Angevin, R.
Garcia, L.
Fernández-Rodríguez, Á.
Saracco, J.
André, J. M.
Lespinet-Najib, V.
Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement
title Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement
title_full Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement
title_fullStr Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement
title_full_unstemmed Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement
title_short Impact of Speller Size on a Visual P300 Brain-Computer Interface (BCI) System under Two Conditions of Constraint for Eye Movement
title_sort impact of speller size on a visual p300 brain-computer interface (bci) system under two conditions of constraint for eye movement
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6636581/
https://www.ncbi.nlm.nih.gov/pubmed/31354802
http://dx.doi.org/10.1155/2019/7876248
work_keys_str_mv AT ronangevinr impactofspellersizeonavisualp300braincomputerinterfacebcisystemundertwoconditionsofconstraintforeyemovement
AT garcial impactofspellersizeonavisualp300braincomputerinterfacebcisystemundertwoconditionsofconstraintforeyemovement
AT fernandezrodrigueza impactofspellersizeonavisualp300braincomputerinterfacebcisystemundertwoconditionsofconstraintforeyemovement
AT saraccoj impactofspellersizeonavisualp300braincomputerinterfacebcisystemundertwoconditionsofconstraintforeyemovement
AT andrejm impactofspellersizeonavisualp300braincomputerinterfacebcisystemundertwoconditionsofconstraintforeyemovement
AT lespinetnajibv impactofspellersizeonavisualp300braincomputerinterfacebcisystemundertwoconditionsofconstraintforeyemovement