Cargando…

Management of venous perforation during central venous catheterization in hemodialysis patients: Three case reports

RATIONALE: In recent years, central venous catheterization (CVC) has become widely used for hemodialysis patients. Based on 3 cases, we discussed the detection and management of venous perforation at an early stage. PATIENTS CONCERNS: Patients 1 (male, 77 years), 2 (male, 82 years), and 3 (male, 30...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Li-Yun, Chen, De-Jun, Wang, Sha-Sha, Chen, Lu, Qi, Feng, Liu, Man-Man
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6636942/
https://www.ncbi.nlm.nih.gov/pubmed/31232976
http://dx.doi.org/10.1097/MD.0000000000016182
Descripción
Sumario:RATIONALE: In recent years, central venous catheterization (CVC) has become widely used for hemodialysis patients. Based on 3 cases, we discussed the detection and management of venous perforation at an early stage. PATIENTS CONCERNS: Patients 1 (male, 77 years), 2 (male, 82 years), and 3 (male, 30 years) were diagnosed with uremia and underwent hemodialysis. DIAGNOSES: Computed tomography suggested pneumomediastinum in patient 1 and pneumothorax in patient 2 after a replacement of the temporary hemodialysis catheter. In patient 3, X-ray suggested that the tip of the catheter was approximately at the plane of the fifth thoracic vertebrate after the temporary catheter was placed. INTERVENTIONS: In patients 1 and 2, the catheters were maintained where they were for about 2 weeks until a false lumen formed outside the catheter. In patient 3, the catheter was withdrawn at once when vein perforation was observed. OUTCOME: In patients 1 and 2, the catheters were adjusted successfully under digital subtraction angiography (DSA) guidance 2 weeks later. In patient 3, hemothorax developed, and a total of approximately 1000 mL of bloody fluid was drained. LESSONS: When venous perforation occurs during CVC, it is safer and more reliable to adjust or withdraw the catheter under DSA guidance after a false lumen forms outside the catheter.