Force, impulse and energy during falling with and without knee protection: an in-vitro study
The mechanics of protective knee padding mitigating injury from a high-force fall have not been investigated in real-life scenarios to date. This study compares the effect of wearing knee pads to unprotected impact on a hard surface. We hypothesized that knee pads reduce the force and energy transmi...