Cargando…

Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure

BACKGROUND: The ubiquitous use of dental amalgam for over 180 years has resulted in the exposure of millions of dental workers to mercury. Dental amalgam contains approximately 50% mercury. Dental workers, including dentists, dental assistants, and dental hygienists, have been shown to have increase...

Descripción completa

Detalles Bibliográficos
Autores principales: Warwick, David, Young, Matt, Palmer, Joe, Ermel, Robin Warwick
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6637613/
https://www.ncbi.nlm.nih.gov/pubmed/31346345
http://dx.doi.org/10.1186/s12995-019-0240-2
_version_ 1783436278371450880
author Warwick, David
Young, Matt
Palmer, Joe
Ermel, Robin Warwick
author_facet Warwick, David
Young, Matt
Palmer, Joe
Ermel, Robin Warwick
author_sort Warwick, David
collection PubMed
description BACKGROUND: The ubiquitous use of dental amalgam for over 180 years has resulted in the exposure of millions of dental workers to mercury. Dental amalgam contains approximately 50% mercury. Dental workers, including dentists, dental assistants, and dental hygienists, have been shown to have increased levels of mercury and suffer more from health issues related to mercury exposure than the general public. Mercury is known to be absorbed via inhalation or through the skin. There are many routine dental procedures that require the removal of dental amalgam by using the dental high-speed drill, which we suspected generates an occupational mercury exposure that is not sufficiently recognized. RESULTS: We showed that drilling dental amalgam generates particulate that volatilizes significant amounts of mercury vapor generally for more than an hour after removal. The levels of mercury vapor created by this procedure frequently exceed the safety thresholds of several jurisdictions and agencies. CONCLUSIONS: A significant, underrecognized source of localized exposure to mercury vapor was identified in this study. The vapor was created by microgram levels of particulate generated from dental amalgam removal with a high-speed dental drill, even when all feasible engineering controls were used to reduce mercury exposure. This exposure may explain why dental workers incur health effects when safety thresholds are not breached. The dispersion patterns for the particulate are not known, so the use of effective skin barriers and inhalation protection are required during amalgam removal to protect the dental worker from this form of occupational mercury exposure. Standard methodologies for occupational mercury exposure assessment appear to be inadequate when assessing mercury exposure during amalgam removal. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12995-019-0240-2) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6637613
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66376132019-07-25 Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure Warwick, David Young, Matt Palmer, Joe Ermel, Robin Warwick J Occup Med Toxicol Research BACKGROUND: The ubiquitous use of dental amalgam for over 180 years has resulted in the exposure of millions of dental workers to mercury. Dental amalgam contains approximately 50% mercury. Dental workers, including dentists, dental assistants, and dental hygienists, have been shown to have increased levels of mercury and suffer more from health issues related to mercury exposure than the general public. Mercury is known to be absorbed via inhalation or through the skin. There are many routine dental procedures that require the removal of dental amalgam by using the dental high-speed drill, which we suspected generates an occupational mercury exposure that is not sufficiently recognized. RESULTS: We showed that drilling dental amalgam generates particulate that volatilizes significant amounts of mercury vapor generally for more than an hour after removal. The levels of mercury vapor created by this procedure frequently exceed the safety thresholds of several jurisdictions and agencies. CONCLUSIONS: A significant, underrecognized source of localized exposure to mercury vapor was identified in this study. The vapor was created by microgram levels of particulate generated from dental amalgam removal with a high-speed dental drill, even when all feasible engineering controls were used to reduce mercury exposure. This exposure may explain why dental workers incur health effects when safety thresholds are not breached. The dispersion patterns for the particulate are not known, so the use of effective skin barriers and inhalation protection are required during amalgam removal to protect the dental worker from this form of occupational mercury exposure. Standard methodologies for occupational mercury exposure assessment appear to be inadequate when assessing mercury exposure during amalgam removal. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12995-019-0240-2) contains supplementary material, which is available to authorized users. BioMed Central 2019-07-17 /pmc/articles/PMC6637613/ /pubmed/31346345 http://dx.doi.org/10.1186/s12995-019-0240-2 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Warwick, David
Young, Matt
Palmer, Joe
Ermel, Robin Warwick
Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure
title Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure
title_full Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure
title_fullStr Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure
title_full_unstemmed Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure
title_short Mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure
title_sort mercury vapor volatilization from particulate generated from dental amalgam removal with a high-speed dental drill – a significant source of exposure
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6637613/
https://www.ncbi.nlm.nih.gov/pubmed/31346345
http://dx.doi.org/10.1186/s12995-019-0240-2
work_keys_str_mv AT warwickdavid mercuryvaporvolatilizationfromparticulategeneratedfromdentalamalgamremovalwithahighspeeddentaldrillasignificantsourceofexposure
AT youngmatt mercuryvaporvolatilizationfromparticulategeneratedfromdentalamalgamremovalwithahighspeeddentaldrillasignificantsourceofexposure
AT palmerjoe mercuryvaporvolatilizationfromparticulategeneratedfromdentalamalgamremovalwithahighspeeddentaldrillasignificantsourceofexposure
AT ermelrobinwarwick mercuryvaporvolatilizationfromparticulategeneratedfromdentalamalgamremovalwithahighspeeddentaldrillasignificantsourceofexposure