Cargando…

Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills

BACKGROUND: Current methods of assessing competence in acquiring point-of-care ultrasound images are inadequate. They rely upon cumbersome rating systems that do not depend on the actual outcome measured and lack evidence of validity. We describe a new method that uses a rigorous statistical model t...

Descripción completa

Detalles Bibliográficos
Autores principales: Lucas, Brian P., D’Addio, Antonietta, Block, Clay, Manning, Harold L., Remillard, Brian, Leiter, James C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Milan 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6638581/
https://www.ncbi.nlm.nih.gov/pubmed/31359267
http://dx.doi.org/10.1186/s13089-019-0119-6
_version_ 1783436359702151168
author Lucas, Brian P.
D’Addio, Antonietta
Block, Clay
Manning, Harold L.
Remillard, Brian
Leiter, James C.
author_facet Lucas, Brian P.
D’Addio, Antonietta
Block, Clay
Manning, Harold L.
Remillard, Brian
Leiter, James C.
author_sort Lucas, Brian P.
collection PubMed
description BACKGROUND: Current methods of assessing competence in acquiring point-of-care ultrasound images are inadequate. They rely upon cumbersome rating systems that do not depend on the actual outcome measured and lack evidence of validity. We describe a new method that uses a rigorous statistical model to assess performance of individual trainees based on the actual task, image acquisition. Measurements obtained from the images acquired (the actual desired outcome) are themselves used to validate effective training and competence acquiring ultrasound images. We enrolled a convenience sample of 21 spontaneously breathing adults from a general medicine ward. In random order, two trainees (A and B) and an instructor contemporaneously acquired point-of-care ultrasound images of the inferior vena cava and the right internal jugular vein from the same patients. Blinded diameter measurements from each ultrasound were analyzed quantitatively using a multilevel model. Consistent mean differences between each trainee’s and the instructor’s images were ascribed to systematic acquisition errors, indicative of poor measurement technique and a need for further training. Wider variances were attributed to sporadic errors, indicative of inconsistent application of measurement technique across patients. In addition, the instructor recorded qualitative observations of each trainee’s performance during image acquisition. RESULTS: For all four diameters, the means and variances of measurements from trainee A’s images differed significantly from the instructor’s, whereas those from trainee B’s images were comparable. Techniques directly observed by the instructor supported these model-derived findings. For example, mean anteroposterior diameters of the internal jugular vein obtained from trainee A’s images were 3.8 mm (90% CI 2.3–5.4) smaller than from the instructor’s; this model-derived finding matched the instructor’s observation that trainee A compressed the vein during acquisition. Instructor summative assessments agreed with model-derived findings, providing internal validation of the descriptive and quantitative assessments of competence acquiring ultrasound images. CONCLUSIONS: Clinical measurements obtained from point-of-care ultrasound images acquired contemporaneously by trainees and an instructor can be used to quantitatively assess the image acquisition competence of specific trainees. This method may obviate resource-intensive qualitative rating systems that are based on ultrasound image quality and direct observation, while also helping instructors guide remediation. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13089-019-0119-6) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6638581
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-66385812019-07-25 Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills Lucas, Brian P. D’Addio, Antonietta Block, Clay Manning, Harold L. Remillard, Brian Leiter, James C. Ultrasound J Original Article BACKGROUND: Current methods of assessing competence in acquiring point-of-care ultrasound images are inadequate. They rely upon cumbersome rating systems that do not depend on the actual outcome measured and lack evidence of validity. We describe a new method that uses a rigorous statistical model to assess performance of individual trainees based on the actual task, image acquisition. Measurements obtained from the images acquired (the actual desired outcome) are themselves used to validate effective training and competence acquiring ultrasound images. We enrolled a convenience sample of 21 spontaneously breathing adults from a general medicine ward. In random order, two trainees (A and B) and an instructor contemporaneously acquired point-of-care ultrasound images of the inferior vena cava and the right internal jugular vein from the same patients. Blinded diameter measurements from each ultrasound were analyzed quantitatively using a multilevel model. Consistent mean differences between each trainee’s and the instructor’s images were ascribed to systematic acquisition errors, indicative of poor measurement technique and a need for further training. Wider variances were attributed to sporadic errors, indicative of inconsistent application of measurement technique across patients. In addition, the instructor recorded qualitative observations of each trainee’s performance during image acquisition. RESULTS: For all four diameters, the means and variances of measurements from trainee A’s images differed significantly from the instructor’s, whereas those from trainee B’s images were comparable. Techniques directly observed by the instructor supported these model-derived findings. For example, mean anteroposterior diameters of the internal jugular vein obtained from trainee A’s images were 3.8 mm (90% CI 2.3–5.4) smaller than from the instructor’s; this model-derived finding matched the instructor’s observation that trainee A compressed the vein during acquisition. Instructor summative assessments agreed with model-derived findings, providing internal validation of the descriptive and quantitative assessments of competence acquiring ultrasound images. CONCLUSIONS: Clinical measurements obtained from point-of-care ultrasound images acquired contemporaneously by trainees and an instructor can be used to quantitatively assess the image acquisition competence of specific trainees. This method may obviate resource-intensive qualitative rating systems that are based on ultrasound image quality and direct observation, while also helping instructors guide remediation. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13089-019-0119-6) contains supplementary material, which is available to authorized users. Springer Milan 2019-02-22 /pmc/articles/PMC6638581/ /pubmed/31359267 http://dx.doi.org/10.1186/s13089-019-0119-6 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Lucas, Brian P.
D’Addio, Antonietta
Block, Clay
Manning, Harold L.
Remillard, Brian
Leiter, James C.
Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
title Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
title_full Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
title_fullStr Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
title_full_unstemmed Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
title_short Clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
title_sort clinical measurements obtained from point-of-care ultrasound images to assess acquisition skills
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6638581/
https://www.ncbi.nlm.nih.gov/pubmed/31359267
http://dx.doi.org/10.1186/s13089-019-0119-6
work_keys_str_mv AT lucasbrianp clinicalmeasurementsobtainedfrompointofcareultrasoundimagestoassessacquisitionskills
AT daddioantonietta clinicalmeasurementsobtainedfrompointofcareultrasoundimagestoassessacquisitionskills
AT blockclay clinicalmeasurementsobtainedfrompointofcareultrasoundimagestoassessacquisitionskills
AT manningharoldl clinicalmeasurementsobtainedfrompointofcareultrasoundimagestoassessacquisitionskills
AT remillardbrian clinicalmeasurementsobtainedfrompointofcareultrasoundimagestoassessacquisitionskills
AT leiterjamesc clinicalmeasurementsobtainedfrompointofcareultrasoundimagestoassessacquisitionskills