Cargando…

Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study

BACKGROUND: A fast and diagnostic accurate tool to assess the unselected category of high-acuity patients, in whom the underlying pathology is not always obvious, is needed in the emergency departments (ED). We aim to describe the feasibility, validity and diagnostic yield of a routine whole-body-fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Riishede, M., Laursen, C. B., Teglbjærg, L. S., Rancinger, E., Pedersen, P. B., Luef, S. M., Clausen, J. H., Graumann, O., Lassen, A. T., Baatrup, G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Milan 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6638611/
https://www.ncbi.nlm.nih.gov/pubmed/31359192
http://dx.doi.org/10.1186/s13089-019-0126-7
_version_ 1783436365394870272
author Riishede, M.
Laursen, C. B.
Teglbjærg, L. S.
Rancinger, E.
Pedersen, P. B.
Luef, S. M.
Clausen, J. H.
Graumann, O.
Lassen, A. T.
Baatrup, G.
author_facet Riishede, M.
Laursen, C. B.
Teglbjærg, L. S.
Rancinger, E.
Pedersen, P. B.
Luef, S. M.
Clausen, J. H.
Graumann, O.
Lassen, A. T.
Baatrup, G.
author_sort Riishede, M.
collection PubMed
description BACKGROUND: A fast and diagnostic accurate tool to assess the unselected category of high-acuity patients, in whom the underlying pathology is not always obvious, is needed in the emergency departments (ED). We aim to describe the feasibility, validity and diagnostic yield of a routine whole-body-focused ultrasonography (wbf-us) in an unselected group of high-acuity ED patients. METHODS: In a prospective observational study, a convenience sample of ED patients (≥ 18 years) with a high-acuity score or systolic blood pressure < 100 mmHg received a routine wbf-us of the heart, lungs, abdomen and deep veins by two non-expert sonographers. Final diagnosis was established by experienced auditors. Investigators were blinded to the patients’ medical history and emergency physicians and auditors were blinded to the investigators assessments. Diagnostic accuracy was assessed by comparing the investigators’ ultrasonography findings to a structured double-blinded clinical audit of patient files. RESULTS: We included 171 patients, initiated a whole-body-focused ultrasonography examination (wbf-us) in 160 and completed it in 128 patients with an average time of a full examination of 28 min. We found pathology in 65/171 (38%) of the patients whose most frequent symptoms upon arrival were cardiopulmonary. Among the patients who received wbf-us, we found the majority of pathology by wbf-us of the lungs (n = 50, 31%), the heart (n = 26, 16%), few in the abdomen (n = 5, 3%) and none in the deep veins. The overall sensitivity was 50–100%, specificity 84–94%, positive predictive value 11–44% and negative predictive value 94–100%. CONCLUSION: Focused cardiopulmonary ultrasonography might be considered for routine use in high-acuity ED patients with cardiopulmonary symptoms whereas focused ultrasonography of the abdomen and deep veins performed by non-expert sonographers only seems indicated in selected patients. Trial registration Danish Data Protection Agency (ID 13/12076). Committee on Biomedical Research Ethics for the Region of Southern Denmark (ID S-20130047). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13089-019-0126-7) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6638611
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Milan
record_format MEDLINE/PubMed
spelling pubmed-66386112019-07-25 Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study Riishede, M. Laursen, C. B. Teglbjærg, L. S. Rancinger, E. Pedersen, P. B. Luef, S. M. Clausen, J. H. Graumann, O. Lassen, A. T. Baatrup, G. Ultrasound J Original Article BACKGROUND: A fast and diagnostic accurate tool to assess the unselected category of high-acuity patients, in whom the underlying pathology is not always obvious, is needed in the emergency departments (ED). We aim to describe the feasibility, validity and diagnostic yield of a routine whole-body-focused ultrasonography (wbf-us) in an unselected group of high-acuity ED patients. METHODS: In a prospective observational study, a convenience sample of ED patients (≥ 18 years) with a high-acuity score or systolic blood pressure < 100 mmHg received a routine wbf-us of the heart, lungs, abdomen and deep veins by two non-expert sonographers. Final diagnosis was established by experienced auditors. Investigators were blinded to the patients’ medical history and emergency physicians and auditors were blinded to the investigators assessments. Diagnostic accuracy was assessed by comparing the investigators’ ultrasonography findings to a structured double-blinded clinical audit of patient files. RESULTS: We included 171 patients, initiated a whole-body-focused ultrasonography examination (wbf-us) in 160 and completed it in 128 patients with an average time of a full examination of 28 min. We found pathology in 65/171 (38%) of the patients whose most frequent symptoms upon arrival were cardiopulmonary. Among the patients who received wbf-us, we found the majority of pathology by wbf-us of the lungs (n = 50, 31%), the heart (n = 26, 16%), few in the abdomen (n = 5, 3%) and none in the deep veins. The overall sensitivity was 50–100%, specificity 84–94%, positive predictive value 11–44% and negative predictive value 94–100%. CONCLUSION: Focused cardiopulmonary ultrasonography might be considered for routine use in high-acuity ED patients with cardiopulmonary symptoms whereas focused ultrasonography of the abdomen and deep veins performed by non-expert sonographers only seems indicated in selected patients. Trial registration Danish Data Protection Agency (ID 13/12076). Committee on Biomedical Research Ethics for the Region of Southern Denmark (ID S-20130047). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13089-019-0126-7) contains supplementary material, which is available to authorized users. Springer Milan 2019-05-27 /pmc/articles/PMC6638611/ /pubmed/31359192 http://dx.doi.org/10.1186/s13089-019-0126-7 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Riishede, M.
Laursen, C. B.
Teglbjærg, L. S.
Rancinger, E.
Pedersen, P. B.
Luef, S. M.
Clausen, J. H.
Graumann, O.
Lassen, A. T.
Baatrup, G.
Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study
title Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study
title_full Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study
title_fullStr Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study
title_full_unstemmed Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study
title_short Diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study
title_sort diagnostic value of whole-body-focused ultrasonography in high-acuity patients in the emergency department: a prospective single-center cross-sectional study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6638611/
https://www.ncbi.nlm.nih.gov/pubmed/31359192
http://dx.doi.org/10.1186/s13089-019-0126-7
work_keys_str_mv AT riishedem diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT laursencb diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT teglbjærgls diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT rancingere diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT pedersenpb diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT luefsm diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT clausenjh diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT graumanno diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT lassenat diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy
AT baatrupg diagnosticvalueofwholebodyfocusedultrasonographyinhighacuitypatientsintheemergencydepartmentaprospectivesinglecentercrosssectionalstudy