Cargando…
An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA)
Dizziness is a common condition that is responsible for a significant degree of material morbidity and burden on health services. It is usually episodic and short-lived, so when a patient presents to their clinician, examination is normal. The CAVA (Continuous Ambulatory Vestibular Assessment) devic...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6639326/ https://www.ncbi.nlm.nih.gov/pubmed/31320726 http://dx.doi.org/10.1038/s41598-019-46970-7 |
_version_ | 1783436441592791040 |
---|---|
author | Phillips, John S. Newman, Jacob L. Cox, Stephen J. |
author_facet | Phillips, John S. Newman, Jacob L. Cox, Stephen J. |
author_sort | Phillips, John S. |
collection | PubMed |
description | Dizziness is a common condition that is responsible for a significant degree of material morbidity and burden on health services. It is usually episodic and short-lived, so when a patient presents to their clinician, examination is normal. The CAVA (Continuous Ambulatory Vestibular Assessment) device has been developed to provide continuous monitoring of eye-movements, allowing insight into the physiological parameters present during a dizziness attack. This article describes the first clinical investigation into the medical and technical aspects of this new diagnostic system. Seventeen healthy subjects wore the device near continuously for up to thirty days, artificially inducing nystagmus on eight occasions. 405 days’ worth of data was captured, comprising around four billion data points. A computer algorithm developed to detect nystagmus demonstrated a sensitivity of 99.1% (95% CI: 95.13% to 99.98%) and a specificity of 98.6% (95% CI: 96.54% to 99.63%). Eighty-two percent of participants wore the device for a minimum of eighty percent of each day. Adverse events were self-limiting and mostly the consequence of skin stripping from the daily replacement of the electrodes. The device was shown to operate effectively as an ambulatory monitor, allowing the reliable detection of artificially induced nystagmus. |
format | Online Article Text |
id | pubmed-6639326 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-66393262019-07-25 An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA) Phillips, John S. Newman, Jacob L. Cox, Stephen J. Sci Rep Article Dizziness is a common condition that is responsible for a significant degree of material morbidity and burden on health services. It is usually episodic and short-lived, so when a patient presents to their clinician, examination is normal. The CAVA (Continuous Ambulatory Vestibular Assessment) device has been developed to provide continuous monitoring of eye-movements, allowing insight into the physiological parameters present during a dizziness attack. This article describes the first clinical investigation into the medical and technical aspects of this new diagnostic system. Seventeen healthy subjects wore the device near continuously for up to thirty days, artificially inducing nystagmus on eight occasions. 405 days’ worth of data was captured, comprising around four billion data points. A computer algorithm developed to detect nystagmus demonstrated a sensitivity of 99.1% (95% CI: 95.13% to 99.98%) and a specificity of 98.6% (95% CI: 96.54% to 99.63%). Eighty-two percent of participants wore the device for a minimum of eighty percent of each day. Adverse events were self-limiting and mostly the consequence of skin stripping from the daily replacement of the electrodes. The device was shown to operate effectively as an ambulatory monitor, allowing the reliable detection of artificially induced nystagmus. Nature Publishing Group UK 2019-07-18 /pmc/articles/PMC6639326/ /pubmed/31320726 http://dx.doi.org/10.1038/s41598-019-46970-7 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Phillips, John S. Newman, Jacob L. Cox, Stephen J. An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA) |
title | An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA) |
title_full | An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA) |
title_fullStr | An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA) |
title_full_unstemmed | An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA) |
title_short | An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for Continuous Ambulatory Vestibular Assessment (CAVA) |
title_sort | investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for continuous ambulatory vestibular assessment (cava) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6639326/ https://www.ncbi.nlm.nih.gov/pubmed/31320726 http://dx.doi.org/10.1038/s41598-019-46970-7 |
work_keys_str_mv | AT phillipsjohns aninvestigationintothediagnosticaccuracyreliabilityacceptabilityandsafetyofanoveldeviceforcontinuousambulatoryvestibularassessmentcava AT newmanjacobl aninvestigationintothediagnosticaccuracyreliabilityacceptabilityandsafetyofanoveldeviceforcontinuousambulatoryvestibularassessmentcava AT coxstephenj aninvestigationintothediagnosticaccuracyreliabilityacceptabilityandsafetyofanoveldeviceforcontinuousambulatoryvestibularassessmentcava AT phillipsjohns investigationintothediagnosticaccuracyreliabilityacceptabilityandsafetyofanoveldeviceforcontinuousambulatoryvestibularassessmentcava AT newmanjacobl investigationintothediagnosticaccuracyreliabilityacceptabilityandsafetyofanoveldeviceforcontinuousambulatoryvestibularassessmentcava AT coxstephenj investigationintothediagnosticaccuracyreliabilityacceptabilityandsafetyofanoveldeviceforcontinuousambulatoryvestibularassessmentcava |