Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia

Preoperative fasting is essential to prevent aspiration and associated complications. However, quite often patients end up fasting for 12 h or more due to changes in the operating room schedules, delays, and postponements. Preoperative fasting may lead to a fluid deficit, which may contribute to per...

Descripción completa

Detalles Bibliográficos
Autores principales: Solanki, Sohan Lal, Kumar, Pooja P, Ambulkar, Reshma P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6639896/
https://www.ncbi.nlm.nih.gov/pubmed/31274504
http://dx.doi.org/10.4103/aca.ACA_70_18
_version_ 1783436551751991296
author Solanki, Sohan Lal
Kumar, Pooja P
Ambulkar, Reshma P
author_facet Solanki, Sohan Lal
Kumar, Pooja P
Ambulkar, Reshma P
author_sort Solanki, Sohan Lal
collection PubMed
description Preoperative fasting is essential to prevent aspiration and associated complications. However, quite often patients end up fasting for 12 h or more due to changes in the operating room schedules, delays, and postponements. Preoperative fasting may lead to a fluid deficit, which may contribute to perioperative discomfort and morbidity. We report a case of 44-year-old female posted for total mastectomy with axillary clearance for carcinoma breast, with prolonged fasting where preoperative R wave amplitude variation along with associated changes in the plethysmograph was noticed on the monitor. 500 milliliters of lactated ringer solution was administered before induction of anesthesia, by the time R wave amplitude variation decreased. Variations in plethysmography became normal after 1 L of fluid administration after induction of anesthesia. Gross R wave amplitude variation is not a very common finding and may predict severe hypovolemia in preoperative area in prolonged fasting patients.
format Online
Article
Text
id pubmed-6639896
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-66398962019-07-31 Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia Solanki, Sohan Lal Kumar, Pooja P Ambulkar, Reshma P Ann Card Anaesth Brief Communication Preoperative fasting is essential to prevent aspiration and associated complications. However, quite often patients end up fasting for 12 h or more due to changes in the operating room schedules, delays, and postponements. Preoperative fasting may lead to a fluid deficit, which may contribute to perioperative discomfort and morbidity. We report a case of 44-year-old female posted for total mastectomy with axillary clearance for carcinoma breast, with prolonged fasting where preoperative R wave amplitude variation along with associated changes in the plethysmograph was noticed on the monitor. 500 milliliters of lactated ringer solution was administered before induction of anesthesia, by the time R wave amplitude variation decreased. Variations in plethysmography became normal after 1 L of fluid administration after induction of anesthesia. Gross R wave amplitude variation is not a very common finding and may predict severe hypovolemia in preoperative area in prolonged fasting patients. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6639896/ /pubmed/31274504 http://dx.doi.org/10.4103/aca.ACA_70_18 Text en Copyright: © 2019 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Brief Communication
Solanki, Sohan Lal
Kumar, Pooja P
Ambulkar, Reshma P
Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia
title Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia
title_full Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia
title_fullStr Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia
title_full_unstemmed Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia
title_short Preoperative “R Wave Amplitude Variation” on Electrocardiogram Predicts Severe Hypovolemia
title_sort preoperative “r wave amplitude variation” on electrocardiogram predicts severe hypovolemia
topic Brief Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6639896/
https://www.ncbi.nlm.nih.gov/pubmed/31274504
http://dx.doi.org/10.4103/aca.ACA_70_18
work_keys_str_mv AT solankisohanlal preoperativerwaveamplitudevariationonelectrocardiogrampredictsseverehypovolemia
AT kumarpoojap preoperativerwaveamplitudevariationonelectrocardiogrampredictsseverehypovolemia
AT ambulkarreshmap preoperativerwaveamplitudevariationonelectrocardiogrampredictsseverehypovolemia