Cargando…

Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study

INTRODUCTION: Miniaturized percutaneous nephrolithotomy (mini-PCNL) requires saline irrigation at high-pressures to maintain visual clarity. However, this may raise the intrarenal pelvic pressures (IRPs) beyond a safe range and may result in a higher complication rate. The aim of this study was to m...

Descripción completa

Detalles Bibliográficos
Autores principales: Rawandale-Patil, Ashish V., Ganpule, Arvind P., Patni, Lokesh G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6640001/
https://www.ncbi.nlm.nih.gov/pubmed/31367070
http://dx.doi.org/10.4103/iju.IJU_261_18
_version_ 1783436573517283328
author Rawandale-Patil, Ashish V.
Ganpule, Arvind P.
Patni, Lokesh G.
author_facet Rawandale-Patil, Ashish V.
Ganpule, Arvind P.
Patni, Lokesh G.
author_sort Rawandale-Patil, Ashish V.
collection PubMed
description INTRODUCTION: Miniaturized percutaneous nephrolithotomy (mini-PCNL) requires saline irrigation at high-pressures to maintain visual clarity. However, this may raise the intrarenal pelvic pressures (IRPs) beyond a safe range and may result in a higher complication rate. The aim of this study was to make and validate an automated pressure saline irrigation system to regulate IRPs during mini-PCNL. MATERIALS AND METHODS: A ureteric catheter was connected to an urodynamic machine and the minimum, maximum, and average IRPs reached during a standard 15 Fr mini-PCNL were measured in ten cases. Next, an intrarenal pressure regulation system (IPRS) was conceptualized, designed, patented, and constructed. IPRS was then tested on a mannequin model using the routine instruments. Lastly, the IPRS was evaluated on – five cases of 15 Fr mini-PCNL. The mean maximum IRP as recorded in the baseline data was set as the maximum permissible pressure on IPRS. The efficacy of IPRS was assessed by measuring the IRP, recorded in parallel, on both the IPRS and the urodynamic machine at various stages of the procedure. RESULTS: The mean maximum IRP reached during baseline evaluation was 25 cm of water which was set as the maximum permissible limit of the IPRS. Evaluation of the IRPS on mannequin models and validation clinical cases showed that IPRS measured the IRP accurately and prevented the pressure surge above the set limits Overall, higher IRPs were recorded during stone pulverization as compared to the other surgical steps. CONCLUSIONS: The current IPRS is the first of its kind open platform, portable, automated pressure saline irrigation system. It precisely monitors and controls the IRP and has the potential to reduce the irrigation pressure-related complications.
format Online
Article
Text
id pubmed-6640001
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-66400012019-07-31 Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study Rawandale-Patil, Ashish V. Ganpule, Arvind P. Patni, Lokesh G. Indian J Urol Original Article INTRODUCTION: Miniaturized percutaneous nephrolithotomy (mini-PCNL) requires saline irrigation at high-pressures to maintain visual clarity. However, this may raise the intrarenal pelvic pressures (IRPs) beyond a safe range and may result in a higher complication rate. The aim of this study was to make and validate an automated pressure saline irrigation system to regulate IRPs during mini-PCNL. MATERIALS AND METHODS: A ureteric catheter was connected to an urodynamic machine and the minimum, maximum, and average IRPs reached during a standard 15 Fr mini-PCNL were measured in ten cases. Next, an intrarenal pressure regulation system (IPRS) was conceptualized, designed, patented, and constructed. IPRS was then tested on a mannequin model using the routine instruments. Lastly, the IPRS was evaluated on – five cases of 15 Fr mini-PCNL. The mean maximum IRP as recorded in the baseline data was set as the maximum permissible pressure on IPRS. The efficacy of IPRS was assessed by measuring the IRP, recorded in parallel, on both the IPRS and the urodynamic machine at various stages of the procedure. RESULTS: The mean maximum IRP reached during baseline evaluation was 25 cm of water which was set as the maximum permissible limit of the IPRS. Evaluation of the IRPS on mannequin models and validation clinical cases showed that IPRS measured the IRP accurately and prevented the pressure surge above the set limits Overall, higher IRPs were recorded during stone pulverization as compared to the other surgical steps. CONCLUSIONS: The current IPRS is the first of its kind open platform, portable, automated pressure saline irrigation system. It precisely monitors and controls the IRP and has the potential to reduce the irrigation pressure-related complications. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6640001/ /pubmed/31367070 http://dx.doi.org/10.4103/iju.IJU_261_18 Text en Copyright: © 2019 Indian Journal of Urology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Rawandale-Patil, Ashish V.
Ganpule, Arvind P.
Patni, Lokesh G.
Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study
title Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study
title_full Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study
title_fullStr Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study
title_full_unstemmed Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study
title_short Development of an innovative intrarenal pressure regulation system for mini-PCNL: A preliminary study
title_sort development of an innovative intrarenal pressure regulation system for mini-pcnl: a preliminary study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6640001/
https://www.ncbi.nlm.nih.gov/pubmed/31367070
http://dx.doi.org/10.4103/iju.IJU_261_18
work_keys_str_mv AT rawandalepatilashishv developmentofaninnovativeintrarenalpressureregulationsystemforminipcnlapreliminarystudy
AT ganpulearvindp developmentofaninnovativeintrarenalpressureregulationsystemforminipcnlapreliminarystudy
AT patnilokeshg developmentofaninnovativeintrarenalpressureregulationsystemforminipcnlapreliminarystudy