Cargando…

Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers

[Image: see text] Quantitative analysis of the influence of intermolecular interactions on the response of electroactive binary monolayers, incorporating the presence of electroinactive coadsorbed species and Marcus–Hush kinetic formalism, has been deduced as an extension of previous models. An expr...

Descripción completa

Detalles Bibliográficos
Autores principales: Gonzalez, Joaquin, Sequí, Jose-Alfonso
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6641222/
https://www.ncbi.nlm.nih.gov/pubmed/31457964
http://dx.doi.org/10.1021/acsomega.7b01995
_version_ 1783436731254571008
author Gonzalez, Joaquin
Sequí, Jose-Alfonso
author_facet Gonzalez, Joaquin
Sequí, Jose-Alfonso
author_sort Gonzalez, Joaquin
collection PubMed
description [Image: see text] Quantitative analysis of the influence of intermolecular interactions on the response of electroactive binary monolayers, incorporating the presence of electroinactive coadsorbed species and Marcus–Hush kinetic formalism, has been deduced as an extension of previous models. An expression for the current–potential relationship in terms of two global phenomenological interaction parameters and the apparent charge-transfer rate constant and formal potential has been obtained and applied to multipotential chronoamperometry for the analysis of intermolecular interaction effects on the kinetics of the charge transfer. Experimental verification of the theoretical framework has been performed with binary ferrocenylundecanethiol/decanethiol monolayers on gold and platinum substrates for different coverage degrees of the redox probe. The increase of the ferrocene coverage gives rise to a slowing down of the charge-transfer process through a decrease of the apparent rate constant above a 90% for gold and platinum electrodes when the surface coverage increases from 1–2 to 15–30%. Significant differences in the magnitude of intermolecular interactions and the symmetry degree of the charge-transfer process are observed between gold and platinum electrodes. Moreover, for high surface coverages of ferrocene, two different domains appear, from which it is possible to carry out a kinetic discrimination of the two responses. Values of the interaction and kinetic parameters have been obtained for the different monolayers under study, and the limit of applicability of this treatment is discussed.
format Online
Article
Text
id pubmed-6641222
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-66412222019-08-27 Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers Gonzalez, Joaquin Sequí, Jose-Alfonso ACS Omega [Image: see text] Quantitative analysis of the influence of intermolecular interactions on the response of electroactive binary monolayers, incorporating the presence of electroinactive coadsorbed species and Marcus–Hush kinetic formalism, has been deduced as an extension of previous models. An expression for the current–potential relationship in terms of two global phenomenological interaction parameters and the apparent charge-transfer rate constant and formal potential has been obtained and applied to multipotential chronoamperometry for the analysis of intermolecular interaction effects on the kinetics of the charge transfer. Experimental verification of the theoretical framework has been performed with binary ferrocenylundecanethiol/decanethiol monolayers on gold and platinum substrates for different coverage degrees of the redox probe. The increase of the ferrocene coverage gives rise to a slowing down of the charge-transfer process through a decrease of the apparent rate constant above a 90% for gold and platinum electrodes when the surface coverage increases from 1–2 to 15–30%. Significant differences in the magnitude of intermolecular interactions and the symmetry degree of the charge-transfer process are observed between gold and platinum electrodes. Moreover, for high surface coverages of ferrocene, two different domains appear, from which it is possible to carry out a kinetic discrimination of the two responses. Values of the interaction and kinetic parameters have been obtained for the different monolayers under study, and the limit of applicability of this treatment is discussed. American Chemical Society 2018-01-30 /pmc/articles/PMC6641222/ /pubmed/31457964 http://dx.doi.org/10.1021/acsomega.7b01995 Text en Copyright © 2018 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Gonzalez, Joaquin
Sequí, Jose-Alfonso
Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers
title Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers
title_full Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers
title_fullStr Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers
title_full_unstemmed Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers
title_short Kinetic Implications of the Presence of Intermolecular Interactions in the Response of Binary Self-Assembled Electroactive Monolayers
title_sort kinetic implications of the presence of intermolecular interactions in the response of binary self-assembled electroactive monolayers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6641222/
https://www.ncbi.nlm.nih.gov/pubmed/31457964
http://dx.doi.org/10.1021/acsomega.7b01995
work_keys_str_mv AT gonzalezjoaquin kineticimplicationsofthepresenceofintermolecularinteractionsintheresponseofbinaryselfassembledelectroactivemonolayers
AT sequijosealfonso kineticimplicationsofthepresenceofintermolecularinteractionsintheresponseofbinaryselfassembledelectroactivemonolayers