Cargando…

Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature

[Image: see text] The chemically reduced graphene oxide (rGO) was prepared by the reduction of graphene oxide by hydrazine hydrate. By varying the reduction time (10 min, 1 h, and 15 h), oxygen functional groups on rGO were tremendously controlled and they were named RG1, RG2, and RG3, respectively....

Descripción completa

Detalles Bibliográficos
Autores principales: Minitha, Cherukutty Ramakrishnan, Anithaa, Velunair Sukumaran, Subramaniam, Vijayakumar, Rajendra Kumar, Ramasamy Thangavelu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6641524/
https://www.ncbi.nlm.nih.gov/pubmed/31458646
http://dx.doi.org/10.1021/acsomega.7b02085
_version_ 1783436801619263488
author Minitha, Cherukutty Ramakrishnan
Anithaa, Velunair Sukumaran
Subramaniam, Vijayakumar
Rajendra Kumar, Ramasamy Thangavelu
author_facet Minitha, Cherukutty Ramakrishnan
Anithaa, Velunair Sukumaran
Subramaniam, Vijayakumar
Rajendra Kumar, Ramasamy Thangavelu
author_sort Minitha, Cherukutty Ramakrishnan
collection PubMed
description [Image: see text] The chemically reduced graphene oxide (rGO) was prepared by the reduction of graphene oxide by hydrazine hydrate. By varying the reduction time (10 min, 1 h, and 15 h), oxygen functional groups on rGO were tremendously controlled and they were named RG1, RG2, and RG3, respectively. Here, we investigate the impact of oxygen functional groups on the detection of ammonia and toluene at room temperature. Their effect on sensing mechanism was analyzed by first-principles calculation-based density functional theory. The sensing material was fabricated, and the effect of reduction time shown improved the recovery of ammonia and toluene sensing at room temperature. Structural, morphological, and electrical characterizations were performed on both RG1 and RG3. The sensor response toward toluene vapor of 300 ppm was found to vary 4.4, 2.5, and 3.8% for RG1, RG2, and RG3, respectively. Though RG1 shows higher sensing response with poor recovery, RG3 exhibited complete desorption of toluene after the sensing process with response and recovery times of approximately 40 and 75 s, respectively. The complete recovery of toluene molecules on RG3 is due to the generation of new sites after the reduction of oxygen functionalities on its surface. It could be suggested that these sites provided anchor to ammonia and toluene molecules and good recovery under N(2) purge. Both theoretical and experimental studies revealed that tuning the oxygen functional groups on rGO could play a vital role in the detection of volatile organic compounds (VOCs) on rGO sheets and was discussed in detail. This study could provoke knowledge about rGO-based sensor dependency with oxygen functional groups and shed light on effective monitoring of VOCs under ambient conditions for air quality monitoring applications.
format Online
Article
Text
id pubmed-6641524
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-66415242019-08-27 Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature Minitha, Cherukutty Ramakrishnan Anithaa, Velunair Sukumaran Subramaniam, Vijayakumar Rajendra Kumar, Ramasamy Thangavelu ACS Omega [Image: see text] The chemically reduced graphene oxide (rGO) was prepared by the reduction of graphene oxide by hydrazine hydrate. By varying the reduction time (10 min, 1 h, and 15 h), oxygen functional groups on rGO were tremendously controlled and they were named RG1, RG2, and RG3, respectively. Here, we investigate the impact of oxygen functional groups on the detection of ammonia and toluene at room temperature. Their effect on sensing mechanism was analyzed by first-principles calculation-based density functional theory. The sensing material was fabricated, and the effect of reduction time shown improved the recovery of ammonia and toluene sensing at room temperature. Structural, morphological, and electrical characterizations were performed on both RG1 and RG3. The sensor response toward toluene vapor of 300 ppm was found to vary 4.4, 2.5, and 3.8% for RG1, RG2, and RG3, respectively. Though RG1 shows higher sensing response with poor recovery, RG3 exhibited complete desorption of toluene after the sensing process with response and recovery times of approximately 40 and 75 s, respectively. The complete recovery of toluene molecules on RG3 is due to the generation of new sites after the reduction of oxygen functionalities on its surface. It could be suggested that these sites provided anchor to ammonia and toluene molecules and good recovery under N(2) purge. Both theoretical and experimental studies revealed that tuning the oxygen functional groups on rGO could play a vital role in the detection of volatile organic compounds (VOCs) on rGO sheets and was discussed in detail. This study could provoke knowledge about rGO-based sensor dependency with oxygen functional groups and shed light on effective monitoring of VOCs under ambient conditions for air quality monitoring applications. American Chemical Society 2018-04-12 /pmc/articles/PMC6641524/ /pubmed/31458646 http://dx.doi.org/10.1021/acsomega.7b02085 Text en Copyright © 2018 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Minitha, Cherukutty Ramakrishnan
Anithaa, Velunair Sukumaran
Subramaniam, Vijayakumar
Rajendra Kumar, Ramasamy Thangavelu
Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature
title Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature
title_full Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature
title_fullStr Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature
title_full_unstemmed Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature
title_short Impact of Oxygen Functional Groups on Reduced Graphene Oxide-Based Sensors for Ammonia and Toluene Detection at Room Temperature
title_sort impact of oxygen functional groups on reduced graphene oxide-based sensors for ammonia and toluene detection at room temperature
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6641524/
https://www.ncbi.nlm.nih.gov/pubmed/31458646
http://dx.doi.org/10.1021/acsomega.7b02085
work_keys_str_mv AT minithacherukuttyramakrishnan impactofoxygenfunctionalgroupsonreducedgrapheneoxidebasedsensorsforammoniaandtoluenedetectionatroomtemperature
AT anithaavelunairsukumaran impactofoxygenfunctionalgroupsonreducedgrapheneoxidebasedsensorsforammoniaandtoluenedetectionatroomtemperature
AT subramaniamvijayakumar impactofoxygenfunctionalgroupsonreducedgrapheneoxidebasedsensorsforammoniaandtoluenedetectionatroomtemperature
AT rajendrakumarramasamythangavelu impactofoxygenfunctionalgroupsonreducedgrapheneoxidebasedsensorsforammoniaandtoluenedetectionatroomtemperature