Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000

BACKGROUND: Protein induced by vitamin K antagonist‐II (PIVKA‐II), in addition to alpha‐fetoprotein, is a useful tumor marker for diagnosis of hepatocellular carcinoma (HCC). We evaluated the analytical performance of the HISCL‐5000 analyzer (Sysmex Corporation) in the measurement of serum PIVKA‐II....

Descripción completa

Detalles Bibliográficos
Autores principales: Ryu, Mi Ra, Kang, Eun‐Suk, Park, Hyung‐Doo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6642327/
https://www.ncbi.nlm.nih.gov/pubmed/31131509
http://dx.doi.org/10.1002/jcla.22921
_version_ 1783436959313559552
author Ryu, Mi Ra
Kang, Eun‐Suk
Park, Hyung‐Doo
author_facet Ryu, Mi Ra
Kang, Eun‐Suk
Park, Hyung‐Doo
author_sort Ryu, Mi Ra
collection PubMed
description BACKGROUND: Protein induced by vitamin K antagonist‐II (PIVKA‐II), in addition to alpha‐fetoprotein, is a useful tumor marker for diagnosis of hepatocellular carcinoma (HCC). We evaluated the analytical performance of the HISCL‐5000 analyzer (Sysmex Corporation) in the measurement of serum PIVKA‐II. METHODS: We evaluated the precision and linearity of PIVKA‐II assays using the HISCL‐5000 analyzer. Methods using HISCL‐5000, LUMIPULSE G1200 (Fujirebio Diagnostics), and ARCHITECT i2000 (Abbott Diagnostics) were compared according to the guidelines of the Clinical and Laboratory Standards Institute. A total of 501 subjects (median age 59 years, age range 24‐90 years) were enrolled. Among them, 335 were HCC patients, 46 were patients with non‐HCC liver disease, and 120 were healthy individuals. Non‐HCC liver disease included liver cirrhosis, chronic hepatitis, HBV or HCV carrier, hepatic adenoma, and intrahepatic cholangiocarcinoma. RESULTS: Repeatability (%CV) in low‐ and high‐level controls and pooled serum was 2.81%‐10.30%, and within‐laboratory precision was 4.24%‐8.86%. In a linearity test, the coefficient of determination (R (2)) was 0.9957, ranging from 11 to 69 897 mAU/mL. In comparison, the coefficient of correlation (r) was 0.9561‐0.9644, agreement was 93.4%‐97.6%, and the κ value was 0.855‐0.945 among the three analyzers. About 99.2% of healthy individuals and 84.8% of non‐HCC liver disease patients were below the cutoff value (40 mAU/mL) on HISCL‐5000. CONCLUSIONS: A PIVKA‐II assay using HISCL‐5000 showed acceptable analytical performance including precision, linearity, and method comparison. This indicates that HISCL‐5000 can be potentially helpful in clinical laboratories.
format Online
Article
Text
id pubmed-6642327
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-66423272019-11-12 Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000 Ryu, Mi Ra Kang, Eun‐Suk Park, Hyung‐Doo J Clin Lab Anal Research Articles BACKGROUND: Protein induced by vitamin K antagonist‐II (PIVKA‐II), in addition to alpha‐fetoprotein, is a useful tumor marker for diagnosis of hepatocellular carcinoma (HCC). We evaluated the analytical performance of the HISCL‐5000 analyzer (Sysmex Corporation) in the measurement of serum PIVKA‐II. METHODS: We evaluated the precision and linearity of PIVKA‐II assays using the HISCL‐5000 analyzer. Methods using HISCL‐5000, LUMIPULSE G1200 (Fujirebio Diagnostics), and ARCHITECT i2000 (Abbott Diagnostics) were compared according to the guidelines of the Clinical and Laboratory Standards Institute. A total of 501 subjects (median age 59 years, age range 24‐90 years) were enrolled. Among them, 335 were HCC patients, 46 were patients with non‐HCC liver disease, and 120 were healthy individuals. Non‐HCC liver disease included liver cirrhosis, chronic hepatitis, HBV or HCV carrier, hepatic adenoma, and intrahepatic cholangiocarcinoma. RESULTS: Repeatability (%CV) in low‐ and high‐level controls and pooled serum was 2.81%‐10.30%, and within‐laboratory precision was 4.24%‐8.86%. In a linearity test, the coefficient of determination (R (2)) was 0.9957, ranging from 11 to 69 897 mAU/mL. In comparison, the coefficient of correlation (r) was 0.9561‐0.9644, agreement was 93.4%‐97.6%, and the κ value was 0.855‐0.945 among the three analyzers. About 99.2% of healthy individuals and 84.8% of non‐HCC liver disease patients were below the cutoff value (40 mAU/mL) on HISCL‐5000. CONCLUSIONS: A PIVKA‐II assay using HISCL‐5000 showed acceptable analytical performance including precision, linearity, and method comparison. This indicates that HISCL‐5000 can be potentially helpful in clinical laboratories. John Wiley and Sons Inc. 2019-05-26 /pmc/articles/PMC6642327/ /pubmed/31131509 http://dx.doi.org/10.1002/jcla.22921 Text en © 2019 The Authors. Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Ryu, Mi Ra
Kang, Eun‐Suk
Park, Hyung‐Doo
Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000
title Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000
title_full Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000
title_fullStr Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000
title_full_unstemmed Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000
title_short Performance evaluation of serum PIVKA‐II measurement using HISCL‐5000 and a method comparison of HISCL‐5000, LUMIPULSE G1200, and ARCHITECT i2000
title_sort performance evaluation of serum pivka‐ii measurement using hiscl‐5000 and a method comparison of hiscl‐5000, lumipulse g1200, and architect i2000
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6642327/
https://www.ncbi.nlm.nih.gov/pubmed/31131509
http://dx.doi.org/10.1002/jcla.22921
work_keys_str_mv AT ryumira performanceevaluationofserumpivkaiimeasurementusinghiscl5000andamethodcomparisonofhiscl5000lumipulseg1200andarchitecti2000
AT kangeunsuk performanceevaluationofserumpivkaiimeasurementusinghiscl5000andamethodcomparisonofhiscl5000lumipulseg1200andarchitecti2000
AT parkhyungdoo performanceevaluationofserumpivkaiimeasurementusinghiscl5000andamethodcomparisonofhiscl5000lumipulseg1200andarchitecti2000