Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot

INTRODUCTION: Functional electrical stimulation uses clinician-set parameters to modify stimulation. This study aimed to investigate whether timing parameters in the ODFS Pace functional electrical stimulation device have an effect on the gait of the general population of functional electrical stimu...

Descripción completa

Detalles Bibliográficos
Autores principales: Marchant, Simon, Michael, Shona, Milner, Laura, Tang, Kit-Tzu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6643319/
https://www.ncbi.nlm.nih.gov/pubmed/31367464
http://dx.doi.org/10.1177/2055668319859142
_version_ 1783437103798943744
author Marchant, Simon
Michael, Shona
Milner, Laura
Tang, Kit-Tzu
author_facet Marchant, Simon
Michael, Shona
Milner, Laura
Tang, Kit-Tzu
author_sort Marchant, Simon
collection PubMed
description INTRODUCTION: Functional electrical stimulation uses clinician-set parameters to modify stimulation. This study aimed to investigate whether timing parameters in the ODFS Pace functional electrical stimulation device have an effect on the gait of the general population of functional electrical stimulation users who have a foot drop. METHODS: Twelve functional electrical stimulation users with foot drop resulting from upper motor neurone disorders were recruited from the functional electrical stimulation Service in Leeds, UK. A crossover trial design was used, comparing adjusted values of rising ramp, delay and extension. Instrumented gait analysis was carried out to measure ankle dorsiflexion during the swing phase of gait, foot clearance from the ground, and speed of ankle plantarflexion at initial contact. The effect of timing parameters on gait kinematics was studied. RESULTS: No statistically significant effects on the measured parts of gait were found for any of the timing parameters. Trends were identified in average mid-swing ground clearance and dorsiflexion associated with the delay and rising ramp timing parameters. CONCLUSIONS: Further work in this area should use larger numbers of participants. Based on these results, the effects of ramping and delay would be of particular interest for further study.
format Online
Article
Text
id pubmed-6643319
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-66433192019-07-31 Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot Marchant, Simon Michael, Shona Milner, Laura Tang, Kit-Tzu J Rehabil Assist Technol Eng IFESS 2017 INTRODUCTION: Functional electrical stimulation uses clinician-set parameters to modify stimulation. This study aimed to investigate whether timing parameters in the ODFS Pace functional electrical stimulation device have an effect on the gait of the general population of functional electrical stimulation users who have a foot drop. METHODS: Twelve functional electrical stimulation users with foot drop resulting from upper motor neurone disorders were recruited from the functional electrical stimulation Service in Leeds, UK. A crossover trial design was used, comparing adjusted values of rising ramp, delay and extension. Instrumented gait analysis was carried out to measure ankle dorsiflexion during the swing phase of gait, foot clearance from the ground, and speed of ankle plantarflexion at initial contact. The effect of timing parameters on gait kinematics was studied. RESULTS: No statistically significant effects on the measured parts of gait were found for any of the timing parameters. Trends were identified in average mid-swing ground clearance and dorsiflexion associated with the delay and rising ramp timing parameters. CONCLUSIONS: Further work in this area should use larger numbers of participants. Based on these results, the effects of ramping and delay would be of particular interest for further study. SAGE Publications 2019-07-19 /pmc/articles/PMC6643319/ /pubmed/31367464 http://dx.doi.org/10.1177/2055668319859142 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle IFESS 2017
Marchant, Simon
Michael, Shona
Milner, Laura
Tang, Kit-Tzu
Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot
title Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot
title_full Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot
title_fullStr Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot
title_full_unstemmed Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot
title_short Effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot
title_sort effects of timing parameter changes on the gait of functional electrical stimulation users with drop foot
topic IFESS 2017
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6643319/
https://www.ncbi.nlm.nih.gov/pubmed/31367464
http://dx.doi.org/10.1177/2055668319859142
work_keys_str_mv AT marchantsimon effectsoftimingparameterchangesonthegaitoffunctionalelectricalstimulationuserswithdropfoot
AT michaelshona effectsoftimingparameterchangesonthegaitoffunctionalelectricalstimulationuserswithdropfoot
AT milnerlaura effectsoftimingparameterchangesonthegaitoffunctionalelectricalstimulationuserswithdropfoot
AT tangkittzu effectsoftimingparameterchangesonthegaitoffunctionalelectricalstimulationuserswithdropfoot