Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via tra...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Thieme Medical Publishers
2019
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6645910/ https://www.ncbi.nlm.nih.gov/pubmed/31330551 http://dx.doi.org/10.1055/s-0039-1687864 |
Sumario: | The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via transapical access after percutaneous transluminal coronary angioplasty of the native vessel perfused by the patent CABG. The procedure was uneventful; an 8-month computed tomography scan showed complete exclusion of the pseudoaneurysm with patency of supra-aortic trunks. |
---|