Cargando…

Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve

The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via tra...

Descripción completa

Detalles Bibliográficos
Autores principales: Antonello, Michele, D'Onofrio, Augusto, Zavatta, Marco, Isabella, Giambattista, Maturi, Carlo, Piazza, Michele, Gerosa, Gino
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical Publishers 2019
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6645910/
https://www.ncbi.nlm.nih.gov/pubmed/31330551
http://dx.doi.org/10.1055/s-0039-1687864
_version_ 1783437522993414144
author Antonello, Michele
D'Onofrio, Augusto
Zavatta, Marco
Isabella, Giambattista
Maturi, Carlo
Piazza, Michele
Gerosa, Gino
author_facet Antonello, Michele
D'Onofrio, Augusto
Zavatta, Marco
Isabella, Giambattista
Maturi, Carlo
Piazza, Michele
Gerosa, Gino
author_sort Antonello, Michele
collection PubMed
description The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via transapical access after percutaneous transluminal coronary angioplasty of the native vessel perfused by the patent CABG. The procedure was uneventful; an 8-month computed tomography scan showed complete exclusion of the pseudoaneurysm with patency of supra-aortic trunks.
format Online
Article
Text
id pubmed-6645910
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Thieme Medical Publishers
record_format MEDLINE/PubMed
spelling pubmed-66459102019-07-23 Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve Antonello, Michele D'Onofrio, Augusto Zavatta, Marco Isabella, Giambattista Maturi, Carlo Piazza, Michele Gerosa, Gino Aorta (Stamford) The authors describe the transapical deployment of a thoracic endograft to exclude a saphenous vein graft proximal anastomotic pseudoaneurysm following coronary artery bypass grafting (CABG) in a 63-year-old male with a prosthetic aortic valve. A standard thoracic endograft has been deployed via transapical access after percutaneous transluminal coronary angioplasty of the native vessel perfused by the patent CABG. The procedure was uneventful; an 8-month computed tomography scan showed complete exclusion of the pseudoaneurysm with patency of supra-aortic trunks. Thieme Medical Publishers 2019-07-22 /pmc/articles/PMC6645910/ /pubmed/31330551 http://dx.doi.org/10.1055/s-0039-1687864 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Antonello, Michele
D'Onofrio, Augusto
Zavatta, Marco
Isabella, Giambattista
Maturi, Carlo
Piazza, Michele
Gerosa, Gino
Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
title Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
title_full Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
title_fullStr Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
title_full_unstemmed Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
title_short Transapical Deployment of Thoracic Stent Graft for Ascending Aorta Coronary Bypass Pseudoaneurysm in a Patient with Prosthetic Aortic Valve
title_sort transapical deployment of thoracic stent graft for ascending aorta coronary bypass pseudoaneurysm in a patient with prosthetic aortic valve
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6645910/
https://www.ncbi.nlm.nih.gov/pubmed/31330551
http://dx.doi.org/10.1055/s-0039-1687864
work_keys_str_mv AT antonellomichele transapicaldeploymentofthoracicstentgraftforascendingaortacoronarybypasspseudoaneurysminapatientwithprostheticaorticvalve
AT donofrioaugusto transapicaldeploymentofthoracicstentgraftforascendingaortacoronarybypasspseudoaneurysminapatientwithprostheticaorticvalve
AT zavattamarco transapicaldeploymentofthoracicstentgraftforascendingaortacoronarybypasspseudoaneurysminapatientwithprostheticaorticvalve
AT isabellagiambattista transapicaldeploymentofthoracicstentgraftforascendingaortacoronarybypasspseudoaneurysminapatientwithprostheticaorticvalve
AT maturicarlo transapicaldeploymentofthoracicstentgraftforascendingaortacoronarybypasspseudoaneurysminapatientwithprostheticaorticvalve
AT piazzamichele transapicaldeploymentofthoracicstentgraftforascendingaortacoronarybypasspseudoaneurysminapatientwithprostheticaorticvalve
AT gerosagino transapicaldeploymentofthoracicstentgraftforascendingaortacoronarybypasspseudoaneurysminapatientwithprostheticaorticvalve