Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD

The aim was to determine whether an artificial intelligence (AI)-based, computer-aided detection (CAD) software can be used to reduce false positive per image (FPPI) on mammograms as compared to an FDA-approved conventional CAD. A retrospective study was performed on a set of 250 full-field digital...

Descripción completa

Detalles Bibliográficos
Autores principales: Mayo, Ray Cody, Kent, Daniel, Sen, Lauren Chang, Kapoor, Megha, Leung, Jessica W. T., Watanabe, Alyssa T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6646646/
https://www.ncbi.nlm.nih.gov/pubmed/30963339
http://dx.doi.org/10.1007/s10278-018-0168-6
_version_ 1783437582484373504
author Mayo, Ray Cody
Kent, Daniel
Sen, Lauren Chang
Kapoor, Megha
Leung, Jessica W. T.
Watanabe, Alyssa T.
author_facet Mayo, Ray Cody
Kent, Daniel
Sen, Lauren Chang
Kapoor, Megha
Leung, Jessica W. T.
Watanabe, Alyssa T.
author_sort Mayo, Ray Cody
collection PubMed
description The aim was to determine whether an artificial intelligence (AI)-based, computer-aided detection (CAD) software can be used to reduce false positive per image (FPPI) on mammograms as compared to an FDA-approved conventional CAD. A retrospective study was performed on a set of 250 full-field digital mammograms between January 1, 2013, and March 31, 2013, and the number of marked regions of interest of two different systems was compared for sensitivity and specificity in cancer detection. The count of false-positive marks per image (FPPI) of the two systems was also evaluated as well as the number of cases that were completely mark-free. All results showed statistically significant reductions in false marks with the use of AI-CAD vs CAD (confidence interval = 95%) with no reduction in sensitivity. There is an overall 69% reduction in FPPI using the AI-based CAD as compared to CAD, consisting of 83% reduction in FPPI for calcifications and 56% reduction for masses. Almost half (48%) of cases showed no AI-CAD markings while only 17% show no conventional CAD marks. There was a significant reduction in FPPI with AI-CAD as compared to CAD for both masses and calcifications at all tissue densities. A 69% decrease in FPPI could result in a 17% decrease in radiologist reading time per case based on prior literature of CAD reading times. Additionally, decreasing false-positive recalls in screening mammography has many direct social and economic benefits.
format Online
Article
Text
id pubmed-6646646
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-66466462019-08-06 Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD Mayo, Ray Cody Kent, Daniel Sen, Lauren Chang Kapoor, Megha Leung, Jessica W. T. Watanabe, Alyssa T. J Digit Imaging Article The aim was to determine whether an artificial intelligence (AI)-based, computer-aided detection (CAD) software can be used to reduce false positive per image (FPPI) on mammograms as compared to an FDA-approved conventional CAD. A retrospective study was performed on a set of 250 full-field digital mammograms between January 1, 2013, and March 31, 2013, and the number of marked regions of interest of two different systems was compared for sensitivity and specificity in cancer detection. The count of false-positive marks per image (FPPI) of the two systems was also evaluated as well as the number of cases that were completely mark-free. All results showed statistically significant reductions in false marks with the use of AI-CAD vs CAD (confidence interval = 95%) with no reduction in sensitivity. There is an overall 69% reduction in FPPI using the AI-based CAD as compared to CAD, consisting of 83% reduction in FPPI for calcifications and 56% reduction for masses. Almost half (48%) of cases showed no AI-CAD markings while only 17% show no conventional CAD marks. There was a significant reduction in FPPI with AI-CAD as compared to CAD for both masses and calcifications at all tissue densities. A 69% decrease in FPPI could result in a 17% decrease in radiologist reading time per case based on prior literature of CAD reading times. Additionally, decreasing false-positive recalls in screening mammography has many direct social and economic benefits. Springer International Publishing 2019-04-08 2019-08 /pmc/articles/PMC6646646/ /pubmed/30963339 http://dx.doi.org/10.1007/s10278-018-0168-6 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Mayo, Ray Cody
Kent, Daniel
Sen, Lauren Chang
Kapoor, Megha
Leung, Jessica W. T.
Watanabe, Alyssa T.
Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD
title Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD
title_full Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD
title_fullStr Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD
title_full_unstemmed Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD
title_short Reduction of False-Positive Markings on Mammograms: a Retrospective Comparison Study Using an Artificial Intelligence-Based CAD
title_sort reduction of false-positive markings on mammograms: a retrospective comparison study using an artificial intelligence-based cad
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6646646/
https://www.ncbi.nlm.nih.gov/pubmed/30963339
http://dx.doi.org/10.1007/s10278-018-0168-6
work_keys_str_mv AT mayoraycody reductionoffalsepositivemarkingsonmammogramsaretrospectivecomparisonstudyusinganartificialintelligencebasedcad
AT kentdaniel reductionoffalsepositivemarkingsonmammogramsaretrospectivecomparisonstudyusinganartificialintelligencebasedcad
AT senlaurenchang reductionoffalsepositivemarkingsonmammogramsaretrospectivecomparisonstudyusinganartificialintelligencebasedcad
AT kapoormegha reductionoffalsepositivemarkingsonmammogramsaretrospectivecomparisonstudyusinganartificialintelligencebasedcad
AT leungjessicawt reductionoffalsepositivemarkingsonmammogramsaretrospectivecomparisonstudyusinganartificialintelligencebasedcad
AT watanabealyssat reductionoffalsepositivemarkingsonmammogramsaretrospectivecomparisonstudyusinganartificialintelligencebasedcad