Cargando…

Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography

To determine whether cmAssist™, an artificial intelligence-based computer-aided detection (AI-CAD) algorithm, can be used to improve radiologists’ sensitivity in breast cancer screening and detection. A blinded retrospective study was performed with a panel of seven radiologists using a cancer-enric...

Descripción completa

Detalles Bibliográficos
Autores principales: Watanabe, Alyssa T., Lim, Vivian, Vu, Hoanh X., Chim, Richard, Weise, Eric, Liu, Jenna, Bradley, William G., Comstock, Christopher E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6646649/
https://www.ncbi.nlm.nih.gov/pubmed/31011956
http://dx.doi.org/10.1007/s10278-019-00192-5
_version_ 1783437583219425280
author Watanabe, Alyssa T.
Lim, Vivian
Vu, Hoanh X.
Chim, Richard
Weise, Eric
Liu, Jenna
Bradley, William G.
Comstock, Christopher E.
author_facet Watanabe, Alyssa T.
Lim, Vivian
Vu, Hoanh X.
Chim, Richard
Weise, Eric
Liu, Jenna
Bradley, William G.
Comstock, Christopher E.
author_sort Watanabe, Alyssa T.
collection PubMed
description To determine whether cmAssist™, an artificial intelligence-based computer-aided detection (AI-CAD) algorithm, can be used to improve radiologists’ sensitivity in breast cancer screening and detection. A blinded retrospective study was performed with a panel of seven radiologists using a cancer-enriched data set from 122 patients that included 90 false-negative mammograms obtained up to 5.8 years prior to diagnosis and 32 BIRADS 1 and 2 patients with a 2-year follow-up of negative diagnosis. The mammograms were performed between February 7, 2008 (earliest) and January 8, 2016 (latest), and were all originally interpreted as negative in conjunction with R2 ImageChecker CAD, version 10.0. In this study, the readers analyzed the 122 studies before and after review of cmAssist™, an AI-CAD software for mammography. The statistical significance of our findings was evaluated using Student’s t test and bootstrap statistical analysis. There was a substantial and significant improvement in radiologist accuracy with use of cmAssist, as demonstrated in the 7.2% increase in the area-under-the-curve (AUC) of the receiver operating characteristic (ROC) curve with two-sided p value < 0.01 for the reader group. All radiologists showed a significant improvement in their cancer detection rate (CDR) with the use of cmAssist (two-sided p value = 0.030, confidence interval = 95%). The readers detected between 25 and 71% (mean 51%) of the early cancers without assistance. With cmAssist, the overall reader CDR was 41 to 76% (mean 62%). The percentage increase in CDR for the reader panel was significant, ranging from 6 to 64% (mean 27%) with the use of cmAssist. There was less than 1% increase in the readers’ false-positive recalls with use of cmAssist. With the use of cmAssist TM, there was a substantial and statistically significant improvement in radiologists’ accuracy and sensitivity for detection of cancers that were originally missed. The percentage increase in CDR for the radiologists in the reader panel ranged from 6 to 64% (mean 27%) with the use of cmAssist, with negligible increase in false-positive recalls. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10278-019-00192-5) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6646649
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-66466492019-08-06 Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography Watanabe, Alyssa T. Lim, Vivian Vu, Hoanh X. Chim, Richard Weise, Eric Liu, Jenna Bradley, William G. Comstock, Christopher E. J Digit Imaging Article To determine whether cmAssist™, an artificial intelligence-based computer-aided detection (AI-CAD) algorithm, can be used to improve radiologists’ sensitivity in breast cancer screening and detection. A blinded retrospective study was performed with a panel of seven radiologists using a cancer-enriched data set from 122 patients that included 90 false-negative mammograms obtained up to 5.8 years prior to diagnosis and 32 BIRADS 1 and 2 patients with a 2-year follow-up of negative diagnosis. The mammograms were performed between February 7, 2008 (earliest) and January 8, 2016 (latest), and were all originally interpreted as negative in conjunction with R2 ImageChecker CAD, version 10.0. In this study, the readers analyzed the 122 studies before and after review of cmAssist™, an AI-CAD software for mammography. The statistical significance of our findings was evaluated using Student’s t test and bootstrap statistical analysis. There was a substantial and significant improvement in radiologist accuracy with use of cmAssist, as demonstrated in the 7.2% increase in the area-under-the-curve (AUC) of the receiver operating characteristic (ROC) curve with two-sided p value < 0.01 for the reader group. All radiologists showed a significant improvement in their cancer detection rate (CDR) with the use of cmAssist (two-sided p value = 0.030, confidence interval = 95%). The readers detected between 25 and 71% (mean 51%) of the early cancers without assistance. With cmAssist, the overall reader CDR was 41 to 76% (mean 62%). The percentage increase in CDR for the reader panel was significant, ranging from 6 to 64% (mean 27%) with the use of cmAssist. There was less than 1% increase in the readers’ false-positive recalls with use of cmAssist. With the use of cmAssist TM, there was a substantial and statistically significant improvement in radiologists’ accuracy and sensitivity for detection of cancers that were originally missed. The percentage increase in CDR for the radiologists in the reader panel ranged from 6 to 64% (mean 27%) with the use of cmAssist, with negligible increase in false-positive recalls. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10278-019-00192-5) contains supplementary material, which is available to authorized users. Springer International Publishing 2019-04-22 2019-08 /pmc/articles/PMC6646649/ /pubmed/31011956 http://dx.doi.org/10.1007/s10278-019-00192-5 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Watanabe, Alyssa T.
Lim, Vivian
Vu, Hoanh X.
Chim, Richard
Weise, Eric
Liu, Jenna
Bradley, William G.
Comstock, Christopher E.
Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography
title Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography
title_full Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography
title_fullStr Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography
title_full_unstemmed Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography
title_short Improved Cancer Detection Using Artificial Intelligence: a Retrospective Evaluation of Missed Cancers on Mammography
title_sort improved cancer detection using artificial intelligence: a retrospective evaluation of missed cancers on mammography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6646649/
https://www.ncbi.nlm.nih.gov/pubmed/31011956
http://dx.doi.org/10.1007/s10278-019-00192-5
work_keys_str_mv AT watanabealyssat improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography
AT limvivian improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography
AT vuhoanhx improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography
AT chimrichard improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography
AT weiseeric improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography
AT liujenna improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography
AT bradleywilliamg improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography
AT comstockchristophere improvedcancerdetectionusingartificialintelligencearetrospectiveevaluationofmissedcancersonmammography