Cargando…

Detection measures for visual inspection of X-ray images of passenger baggage

In visual inspection tasks, such as airport security and medical screening, researchers often use the detection measures d' or A' to analyze detection performance independent of response tendency. However, recent studies that manipulated the frequency of targets (target prevalence) indicat...

Descripción completa

Detalles Bibliográficos
Autores principales: Sterchi, Yanik, Hättenschwiler, Nicole, Schwaninger, Adrian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6647488/
https://www.ncbi.nlm.nih.gov/pubmed/30684203
http://dx.doi.org/10.3758/s13414-018-01654-8
_version_ 1783437735387725824
author Sterchi, Yanik
Hättenschwiler, Nicole
Schwaninger, Adrian
author_facet Sterchi, Yanik
Hättenschwiler, Nicole
Schwaninger, Adrian
author_sort Sterchi, Yanik
collection PubMed
description In visual inspection tasks, such as airport security and medical screening, researchers often use the detection measures d' or A' to analyze detection performance independent of response tendency. However, recent studies that manipulated the frequency of targets (target prevalence) indicate that d(a) with a slope parameter of 0.6 is more valid for such tasks than d' or A'. We investigated the validity of detection measures (d', A', and d(a)) using two experiments. In the first experiment, 31 security officers completed a simulated X-ray baggage inspection task while response tendency was manipulated directly through instruction. The participants knew half of the prohibited items used in the study from training, whereas the other half were novel, thereby establishing two levels of task difficulty. The results demonstrated that for both levels, d' and A' decreased when the criterion became more liberal, whereas d(a) with a slope parameter of 0.6 remained constant. Eye-tracking data indicated that manipulating response tendency affected the decision component of the inspection task rather than search errors. In the second experiment, 124 security officers completed another simulated X-ray baggage inspection task. Receiver operating characteristic (ROC) curves based on confidence ratings provided further support for d(a), and the estimated slope parameter was 0.5. Consistent with previous findings, our results imply that d' and A' are not valid measures of detection performance in X-ray image inspection. We recommend always calculating d(a) with a slope parameter of 0.5 in addition to d' to avoid potentially wrong conclusions if ROC curves are not available.
format Online
Article
Text
id pubmed-6647488
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-66474882019-08-06 Detection measures for visual inspection of X-ray images of passenger baggage Sterchi, Yanik Hättenschwiler, Nicole Schwaninger, Adrian Atten Percept Psychophys Article In visual inspection tasks, such as airport security and medical screening, researchers often use the detection measures d' or A' to analyze detection performance independent of response tendency. However, recent studies that manipulated the frequency of targets (target prevalence) indicate that d(a) with a slope parameter of 0.6 is more valid for such tasks than d' or A'. We investigated the validity of detection measures (d', A', and d(a)) using two experiments. In the first experiment, 31 security officers completed a simulated X-ray baggage inspection task while response tendency was manipulated directly through instruction. The participants knew half of the prohibited items used in the study from training, whereas the other half were novel, thereby establishing two levels of task difficulty. The results demonstrated that for both levels, d' and A' decreased when the criterion became more liberal, whereas d(a) with a slope parameter of 0.6 remained constant. Eye-tracking data indicated that manipulating response tendency affected the decision component of the inspection task rather than search errors. In the second experiment, 124 security officers completed another simulated X-ray baggage inspection task. Receiver operating characteristic (ROC) curves based on confidence ratings provided further support for d(a), and the estimated slope parameter was 0.5. Consistent with previous findings, our results imply that d' and A' are not valid measures of detection performance in X-ray image inspection. We recommend always calculating d(a) with a slope parameter of 0.5 in addition to d' to avoid potentially wrong conclusions if ROC curves are not available. Springer US 2019-01-25 2019 /pmc/articles/PMC6647488/ /pubmed/30684203 http://dx.doi.org/10.3758/s13414-018-01654-8 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Article
Sterchi, Yanik
Hättenschwiler, Nicole
Schwaninger, Adrian
Detection measures for visual inspection of X-ray images of passenger baggage
title Detection measures for visual inspection of X-ray images of passenger baggage
title_full Detection measures for visual inspection of X-ray images of passenger baggage
title_fullStr Detection measures for visual inspection of X-ray images of passenger baggage
title_full_unstemmed Detection measures for visual inspection of X-ray images of passenger baggage
title_short Detection measures for visual inspection of X-ray images of passenger baggage
title_sort detection measures for visual inspection of x-ray images of passenger baggage
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6647488/
https://www.ncbi.nlm.nih.gov/pubmed/30684203
http://dx.doi.org/10.3758/s13414-018-01654-8
work_keys_str_mv AT sterchiyanik detectionmeasuresforvisualinspectionofxrayimagesofpassengerbaggage
AT hattenschwilernicole detectionmeasuresforvisualinspectionofxrayimagesofpassengerbaggage
AT schwaningeradrian detectionmeasuresforvisualinspectionofxrayimagesofpassengerbaggage