Cargando…

Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray

[Image: see text] With the rapid development of nanotechnology, there is urgent need of characterizing techniques; especially determining the particle size distribution directly from solution. Dynamic light scattering is often used but presence of a small number of aggregates can greatly influence t...

Descripción completa

Detalles Bibliográficos
Autores principales: Sögaard, Christian, Simonsson, Isabelle, Abbas, Zareen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2019
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6648206/
https://www.ncbi.nlm.nih.gov/pubmed/31459391
http://dx.doi.org/10.1021/acsomega.8b03264
_version_ 1783437821089939456
author Sögaard, Christian
Simonsson, Isabelle
Abbas, Zareen
author_facet Sögaard, Christian
Simonsson, Isabelle
Abbas, Zareen
author_sort Sögaard, Christian
collection PubMed
description [Image: see text] With the rapid development of nanotechnology, there is urgent need of characterizing techniques; especially determining the particle size distribution directly from solution. Dynamic light scattering is often used but presence of a small number of aggregates can greatly influence the size distribution. Electrospray scanning mobility particle sizer (ES–SMPS) is rapidly emerging as an alternative method in colloidal science. However, a major limitation is the use of silica-coated capillaries, which are negatively charged at pH > 3, and therefore making its use difficult for positively charged nanoparticles. In this work, we have developed the polyether ether ketone (PEEK) capillary for ES–SMPS, which removes this limitation because it carries no charge. We have shown that the new capillary not only produced equally good particle size distributions for negatively charged particles (SiO(2), Au, and latex) as obtained with silica capillaries, but also precise particle size distributions for positively charged particles (TiO(2)). Moreover, the PEEK capillaries are much cheaper than the silica capillaries. Thus, the results shown in this paper strengthen the development of the ES–SMPS method as a versatile method for determining the particle size distributions of colloidal sols directly from solution.
format Online
Article
Text
id pubmed-6648206
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-66482062019-08-27 Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray Sögaard, Christian Simonsson, Isabelle Abbas, Zareen ACS Omega [Image: see text] With the rapid development of nanotechnology, there is urgent need of characterizing techniques; especially determining the particle size distribution directly from solution. Dynamic light scattering is often used but presence of a small number of aggregates can greatly influence the size distribution. Electrospray scanning mobility particle sizer (ES–SMPS) is rapidly emerging as an alternative method in colloidal science. However, a major limitation is the use of silica-coated capillaries, which are negatively charged at pH > 3, and therefore making its use difficult for positively charged nanoparticles. In this work, we have developed the polyether ether ketone (PEEK) capillary for ES–SMPS, which removes this limitation because it carries no charge. We have shown that the new capillary not only produced equally good particle size distributions for negatively charged particles (SiO(2), Au, and latex) as obtained with silica capillaries, but also precise particle size distributions for positively charged particles (TiO(2)). Moreover, the PEEK capillaries are much cheaper than the silica capillaries. Thus, the results shown in this paper strengthen the development of the ES–SMPS method as a versatile method for determining the particle size distributions of colloidal sols directly from solution. American Chemical Society 2019-01-14 /pmc/articles/PMC6648206/ /pubmed/31459391 http://dx.doi.org/10.1021/acsomega.8b03264 Text en Copyright © 2019 American Chemical Society This is an open access article published under a Creative Commons Attribution (CC-BY) License (http://pubs.acs.org/page/policy/authorchoice_ccby_termsofuse.html) , which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited.
spellingShingle Sögaard, Christian
Simonsson, Isabelle
Abbas, Zareen
Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray
title Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray
title_full Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray
title_fullStr Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray
title_full_unstemmed Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray
title_short Development and Evaluation of Polyether Ether Ketone (PEEK) Capillary for Electrospray
title_sort development and evaluation of polyether ether ketone (peek) capillary for electrospray
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6648206/
https://www.ncbi.nlm.nih.gov/pubmed/31459391
http://dx.doi.org/10.1021/acsomega.8b03264
work_keys_str_mv AT sogaardchristian developmentandevaluationofpolyetheretherketonepeekcapillaryforelectrospray
AT simonssonisabelle developmentandevaluationofpolyetheretherketonepeekcapillaryforelectrospray
AT abbaszareen developmentandevaluationofpolyetheretherketonepeekcapillaryforelectrospray