Cargando…

A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis

In hemodialysis, vascular access is usually achieved through an arteriovenous fistula, and a dislodged needle can cause varying degrees of injury to patients. In severe cases, the loss of blood can prove to be fatal. This study proposed a blood leakage detection device for patients during hemodialys...

Descripción completa

Detalles Bibliográficos
Autores principales: Ou, Yang-Kun, Wu, Ming-Jui, Ciou, Wei-Siang, Du, Yi-Chun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651021/
https://www.ncbi.nlm.nih.gov/pubmed/31284443
http://dx.doi.org/10.3390/ijerph16132388
_version_ 1783438248351105024
author Ou, Yang-Kun
Wu, Ming-Jui
Ciou, Wei-Siang
Du, Yi-Chun
author_facet Ou, Yang-Kun
Wu, Ming-Jui
Ciou, Wei-Siang
Du, Yi-Chun
author_sort Ou, Yang-Kun
collection PubMed
description In hemodialysis, vascular access is usually achieved through an arteriovenous fistula, and a dislodged needle can cause varying degrees of injury to patients. In severe cases, the loss of blood can prove to be fatal. This study proposed a blood leakage detection device for patients during hemodialysis (HD). First, the device was tested on a phantom arm, and later in a clinical test on patients receiving HD. The thoughts of the patients and the nursing staff involved were surveyed before and after the introduction of the device. Analysis of the results indicated that the device achieved 100% and 98.9% accuracy rates on the phantom arm test and clinical test, respectively. The results suggested that patients believed the device could reduce their mental anxiety, and the nursing staff considered the device reliable and that it would enhance the quality of care. The proposed detection device can be extended to similar applications for preventing catheter dislodgement, and to improve patient safety and reduce the stress of clinical nursing staff.
format Online
Article
Text
id pubmed-6651021
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66510212019-08-07 A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis Ou, Yang-Kun Wu, Ming-Jui Ciou, Wei-Siang Du, Yi-Chun Int J Environ Res Public Health Article In hemodialysis, vascular access is usually achieved through an arteriovenous fistula, and a dislodged needle can cause varying degrees of injury to patients. In severe cases, the loss of blood can prove to be fatal. This study proposed a blood leakage detection device for patients during hemodialysis (HD). First, the device was tested on a phantom arm, and later in a clinical test on patients receiving HD. The thoughts of the patients and the nursing staff involved were surveyed before and after the introduction of the device. Analysis of the results indicated that the device achieved 100% and 98.9% accuracy rates on the phantom arm test and clinical test, respectively. The results suggested that patients believed the device could reduce their mental anxiety, and the nursing staff considered the device reliable and that it would enhance the quality of care. The proposed detection device can be extended to similar applications for preventing catheter dislodgement, and to improve patient safety and reduce the stress of clinical nursing staff. MDPI 2019-07-05 2019-07 /pmc/articles/PMC6651021/ /pubmed/31284443 http://dx.doi.org/10.3390/ijerph16132388 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ou, Yang-Kun
Wu, Ming-Jui
Ciou, Wei-Siang
Du, Yi-Chun
A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis
title A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis
title_full A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis
title_fullStr A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis
title_full_unstemmed A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis
title_short A Clinical Trial of the Effect of a Blood Leakage Detection Device for Patients during Hemodialysis
title_sort clinical trial of the effect of a blood leakage detection device for patients during hemodialysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651021/
https://www.ncbi.nlm.nih.gov/pubmed/31284443
http://dx.doi.org/10.3390/ijerph16132388
work_keys_str_mv AT ouyangkun aclinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis
AT wumingjui aclinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis
AT ciouweisiang aclinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis
AT duyichun aclinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis
AT ouyangkun clinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis
AT wumingjui clinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis
AT ciouweisiang clinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis
AT duyichun clinicaltrialoftheeffectofabloodleakagedetectiondeviceforpatientsduringhemodialysis