Cargando…

Variation in Compressive Strength of Concrete aross Thickness of Placed Layer

Is the variation in the compressive strength of concrete across the thickness of horizontally cast elements negligibly small or rather needs to be taken into account at the design stage? There are conflicting answers to this question. In order to determine if the compressive strength of concrete var...

Descripción completa

Detalles Bibliográficos
Autor principal: Michałek, Jarosław
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651110/
https://www.ncbi.nlm.nih.gov/pubmed/31284430
http://dx.doi.org/10.3390/ma12132162
_version_ 1783438269361422336
author Michałek, Jarosław
author_facet Michałek, Jarosław
author_sort Michałek, Jarosław
collection PubMed
description Is the variation in the compressive strength of concrete across the thickness of horizontally cast elements negligibly small or rather needs to be taken into account at the design stage? There are conflicting answers to this question. In order to determine if the compressive strength of concrete varies across the thickness of horizontally cast elements, ultrasonic tests and destructive tests were carried out on core samples taken from a 350 mm thick slab made of class C25/30 concrete. Special point-contact probes were used to measure the time taken for the longitudinal ultrasonic wave to pass through the tested sample. The correlation between the velocity of the longitudinal ultrasonic wave and the compressive strength of the concrete in the slab was determined. The structure of the concrete across the thickness of the slab was evaluated using GIMP 2.10.4. It was found that the destructively determined compressive strength varied only slightly (by 3%) across the thickness of the placed layer of concrete. Whereas the averaged ultrasonically determined strength of the concrete in the same samples does not vary across the thickness of the analyzed slab. Therefore, it was concluded that the slight increase in concrete compressive strength with depth below the top surface is a natural thing and need not be taken into account in the assessment of the strength of concrete in the structure.
format Online
Article
Text
id pubmed-6651110
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66511102019-08-07 Variation in Compressive Strength of Concrete aross Thickness of Placed Layer Michałek, Jarosław Materials (Basel) Article Is the variation in the compressive strength of concrete across the thickness of horizontally cast elements negligibly small or rather needs to be taken into account at the design stage? There are conflicting answers to this question. In order to determine if the compressive strength of concrete varies across the thickness of horizontally cast elements, ultrasonic tests and destructive tests were carried out on core samples taken from a 350 mm thick slab made of class C25/30 concrete. Special point-contact probes were used to measure the time taken for the longitudinal ultrasonic wave to pass through the tested sample. The correlation between the velocity of the longitudinal ultrasonic wave and the compressive strength of the concrete in the slab was determined. The structure of the concrete across the thickness of the slab was evaluated using GIMP 2.10.4. It was found that the destructively determined compressive strength varied only slightly (by 3%) across the thickness of the placed layer of concrete. Whereas the averaged ultrasonically determined strength of the concrete in the same samples does not vary across the thickness of the analyzed slab. Therefore, it was concluded that the slight increase in concrete compressive strength with depth below the top surface is a natural thing and need not be taken into account in the assessment of the strength of concrete in the structure. MDPI 2019-07-05 /pmc/articles/PMC6651110/ /pubmed/31284430 http://dx.doi.org/10.3390/ma12132162 Text en © 2019 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Michałek, Jarosław
Variation in Compressive Strength of Concrete aross Thickness of Placed Layer
title Variation in Compressive Strength of Concrete aross Thickness of Placed Layer
title_full Variation in Compressive Strength of Concrete aross Thickness of Placed Layer
title_fullStr Variation in Compressive Strength of Concrete aross Thickness of Placed Layer
title_full_unstemmed Variation in Compressive Strength of Concrete aross Thickness of Placed Layer
title_short Variation in Compressive Strength of Concrete aross Thickness of Placed Layer
title_sort variation in compressive strength of concrete aross thickness of placed layer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651110/
https://www.ncbi.nlm.nih.gov/pubmed/31284430
http://dx.doi.org/10.3390/ma12132162
work_keys_str_mv AT michałekjarosław variationincompressivestrengthofconcretearossthicknessofplacedlayer