Cargando…

Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates

Calcium (titanium, zirconium) hexaorthophosphates with a [NZP] (sodium zirconium phosphate) structure belonging to the NaSiCon (Na Superionic Conductor) family were deposited by atmospheric plasma spraying onto the surfaces of Ti6Al4V substrates. (NaSiCon sensu strictu refers to solids with the chem...

Descripción completa

Detalles Bibliográficos
Autor principal: Heimann, Robert B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651254/
https://www.ncbi.nlm.nih.gov/pubmed/31252516
http://dx.doi.org/10.3390/ma12132059
_version_ 1783438303506202624
author Heimann, Robert B.
author_facet Heimann, Robert B.
author_sort Heimann, Robert B.
collection PubMed
description Calcium (titanium, zirconium) hexaorthophosphates with a [NZP] (sodium zirconium phosphate) structure belonging to the NaSiCon (Na Superionic Conductor) family were deposited by atmospheric plasma spraying onto the surfaces of Ti6Al4V substrates. (NaSiCon sensu strictu refers to solids with the chemical formula Na(1+x)Zr(2)Si(x)P(3−x)O(12), 0 < x < 3. In a broader sense, it is also used for similar compounds where Na, Zr and/or Si are replaced by isovalent elements). The microstructure of the coatings revealed the incongruent melting of the precursor material as ascertained by electron probe microanalysis (EPMA). The adhesion of the coatings to the substrate surface was within the limits specified for biomedical coatings. The solubility of the coatings was tested by immersion in 0.2 molar tris–hydroxymethyl–amino–methane–HCl (TRIS–HCl) buffer and found to be at least one order of magnitude lower than that of conventional hydroxylapatite coatings deposited under comparable conditions. In vitro biocompatibility tests with primary rat bone marrow cells (BMCs) showed a substantial cell proliferation in the presence of fetal bovine serum. Animal tests confirmed that coatings based on calcium (titanium, zirconium) hexaorthophosphates applied to Ti6Al4V rods implanted in the femoral medulla of sheep led to the strong neoformation of dense bone at a stable interface implant-bioceramic coating without coating delamination. Hence, based on their multifarious advantageous properties in the biomedical context, CaTi(4-x)Zr(x)(PO(4))(6) ceramics may be considered the ‘Sleeping Beauty’ of osseoconductive coatings for the stem of hip endoprostheses and dental root implants, osteosynthetic fixation devices, and bioelectric devices including bone growth stimulators.
format Online
Article
Text
id pubmed-6651254
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66512542019-08-07 Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates Heimann, Robert B. Materials (Basel) Article Calcium (titanium, zirconium) hexaorthophosphates with a [NZP] (sodium zirconium phosphate) structure belonging to the NaSiCon (Na Superionic Conductor) family were deposited by atmospheric plasma spraying onto the surfaces of Ti6Al4V substrates. (NaSiCon sensu strictu refers to solids with the chemical formula Na(1+x)Zr(2)Si(x)P(3−x)O(12), 0 < x < 3. In a broader sense, it is also used for similar compounds where Na, Zr and/or Si are replaced by isovalent elements). The microstructure of the coatings revealed the incongruent melting of the precursor material as ascertained by electron probe microanalysis (EPMA). The adhesion of the coatings to the substrate surface was within the limits specified for biomedical coatings. The solubility of the coatings was tested by immersion in 0.2 molar tris–hydroxymethyl–amino–methane–HCl (TRIS–HCl) buffer and found to be at least one order of magnitude lower than that of conventional hydroxylapatite coatings deposited under comparable conditions. In vitro biocompatibility tests with primary rat bone marrow cells (BMCs) showed a substantial cell proliferation in the presence of fetal bovine serum. Animal tests confirmed that coatings based on calcium (titanium, zirconium) hexaorthophosphates applied to Ti6Al4V rods implanted in the femoral medulla of sheep led to the strong neoformation of dense bone at a stable interface implant-bioceramic coating without coating delamination. Hence, based on their multifarious advantageous properties in the biomedical context, CaTi(4-x)Zr(x)(PO(4))(6) ceramics may be considered the ‘Sleeping Beauty’ of osseoconductive coatings for the stem of hip endoprostheses and dental root implants, osteosynthetic fixation devices, and bioelectric devices including bone growth stimulators. MDPI 2019-06-27 /pmc/articles/PMC6651254/ /pubmed/31252516 http://dx.doi.org/10.3390/ma12132059 Text en © 2019 by the author. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Heimann, Robert B.
Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates
title Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates
title_full Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates
title_fullStr Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates
title_full_unstemmed Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates
title_short Plasma-Sprayed Bioactive Ceramic Coatings with High Resorption Resistance Based on Transition Metal-Substituted Calcium Hexaorthophosphates
title_sort plasma-sprayed bioactive ceramic coatings with high resorption resistance based on transition metal-substituted calcium hexaorthophosphates
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651254/
https://www.ncbi.nlm.nih.gov/pubmed/31252516
http://dx.doi.org/10.3390/ma12132059
work_keys_str_mv AT heimannrobertb plasmasprayedbioactiveceramiccoatingswithhighresorptionresistancebasedontransitionmetalsubstitutedcalciumhexaorthophosphates