Cargando…

Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications

In this paper, we report the development of a portable energy-efficient interrogator (Perrogator) for wavelength-based optical sensors. The interrogator is based on a compact solution encompassing a white light source and the spectral convolution between the sensor and a tunable filter, which is acq...

Descripción completa

Detalles Bibliográficos
Autores principales: R. Diaz, Camilo A., Leal-Junior, Arnaldo Gomes, M. Avellar, Letícia, C. Antunes, Paulo F., Pontes, Maria J., Marques, Carlos A., Frizera, Anselmo, N. Ribeiro, Moisés R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651577/
https://www.ncbi.nlm.nih.gov/pubmed/31284380
http://dx.doi.org/10.3390/s19132962
_version_ 1783438379497553920
author R. Diaz, Camilo A.
Leal-Junior, Arnaldo Gomes
M. Avellar, Letícia
C. Antunes, Paulo F.
Pontes, Maria J.
Marques, Carlos A.
Frizera, Anselmo
N. Ribeiro, Moisés R.
author_facet R. Diaz, Camilo A.
Leal-Junior, Arnaldo Gomes
M. Avellar, Letícia
C. Antunes, Paulo F.
Pontes, Maria J.
Marques, Carlos A.
Frizera, Anselmo
N. Ribeiro, Moisés R.
author_sort R. Diaz, Camilo A.
collection PubMed
description In this paper, we report the development of a portable energy-efficient interrogator (Perrogator) for wavelength-based optical sensors. The interrogator is based on a compact solution encompassing a white light source and the spectral convolution between the sensor and a tunable filter, which is acquired by a photodetector, where a microcontroller has two functions: (i) To control the filter tuning and to (ii) acquire the photodetector signal. Then, the data is sent to a single-board computer for further signal processing. Furthermore, the employed single-board computer has a Wi-Fi module, which can be used to send the sensors data to the cloud. The proposed approach resulted in an interrogator with a resolution as high as 3.82 pm (for 15.64 nm sweeping range) and maximum acquisition frequency of about 210 Hz (with lower resolution ~15.30 pm). Perrogator was compared with a commercial fiber Bragg grating (FBG) interrogator for strain measurements and good agreement between both devices was found (1.226 pm/µε for the commercial interrogator and 1.201 pm/µε for the proposed approach with root mean square error of 0.0144 and 0.0153, respectively), where the Perrogator has the additional advantages of lower cost, higher portability and lower energy consumption. In order to demonstrate such advantages in conjunction with the high acquisition frequency allowed us to demonstrate two wearable applications using the proposed interrogation device over FBG and Fabry-Perot interferometer (FPI) sensors. In the first application, an FBG-embedded smart textile for knee angle assessment was used to analyze the gait of a healthy person. Due to the capability of reconstructing the FBG spectra, it was possible to employ a technique based on the FBG wavelength shift and reflectivity to decouple the effects of the bending angle and axial strain on the FBG response. The measurement of the knee angle as well as the estimation of the angular and axial displacements on the grating that can be correlated to the variations of the knee center of rotation were performed. In the second application, a FPI was embedded in a chest band for simultaneous measurement of breath and heart rates, where good agreement (error below 5%) was found with the reference sensors in all analyzed cases.
format Online
Article
Text
id pubmed-6651577
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66515772019-08-08 Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications R. Diaz, Camilo A. Leal-Junior, Arnaldo Gomes M. Avellar, Letícia C. Antunes, Paulo F. Pontes, Maria J. Marques, Carlos A. Frizera, Anselmo N. Ribeiro, Moisés R. Sensors (Basel) Article In this paper, we report the development of a portable energy-efficient interrogator (Perrogator) for wavelength-based optical sensors. The interrogator is based on a compact solution encompassing a white light source and the spectral convolution between the sensor and a tunable filter, which is acquired by a photodetector, where a microcontroller has two functions: (i) To control the filter tuning and to (ii) acquire the photodetector signal. Then, the data is sent to a single-board computer for further signal processing. Furthermore, the employed single-board computer has a Wi-Fi module, which can be used to send the sensors data to the cloud. The proposed approach resulted in an interrogator with a resolution as high as 3.82 pm (for 15.64 nm sweeping range) and maximum acquisition frequency of about 210 Hz (with lower resolution ~15.30 pm). Perrogator was compared with a commercial fiber Bragg grating (FBG) interrogator for strain measurements and good agreement between both devices was found (1.226 pm/µε for the commercial interrogator and 1.201 pm/µε for the proposed approach with root mean square error of 0.0144 and 0.0153, respectively), where the Perrogator has the additional advantages of lower cost, higher portability and lower energy consumption. In order to demonstrate such advantages in conjunction with the high acquisition frequency allowed us to demonstrate two wearable applications using the proposed interrogation device over FBG and Fabry-Perot interferometer (FPI) sensors. In the first application, an FBG-embedded smart textile for knee angle assessment was used to analyze the gait of a healthy person. Due to the capability of reconstructing the FBG spectra, it was possible to employ a technique based on the FBG wavelength shift and reflectivity to decouple the effects of the bending angle and axial strain on the FBG response. The measurement of the knee angle as well as the estimation of the angular and axial displacements on the grating that can be correlated to the variations of the knee center of rotation were performed. In the second application, a FPI was embedded in a chest band for simultaneous measurement of breath and heart rates, where good agreement (error below 5%) was found with the reference sensors in all analyzed cases. MDPI 2019-07-05 /pmc/articles/PMC6651577/ /pubmed/31284380 http://dx.doi.org/10.3390/s19132962 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
R. Diaz, Camilo A.
Leal-Junior, Arnaldo Gomes
M. Avellar, Letícia
C. Antunes, Paulo F.
Pontes, Maria J.
Marques, Carlos A.
Frizera, Anselmo
N. Ribeiro, Moisés R.
Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications
title Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications
title_full Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications
title_fullStr Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications
title_full_unstemmed Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications
title_short Perrogator: A Portable Energy-Efficient Interrogator for Dynamic Monitoring of Wavelength-Based Sensors in Wearable Applications
title_sort perrogator: a portable energy-efficient interrogator for dynamic monitoring of wavelength-based sensors in wearable applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651577/
https://www.ncbi.nlm.nih.gov/pubmed/31284380
http://dx.doi.org/10.3390/s19132962
work_keys_str_mv AT rdiazcamiloa perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications
AT lealjuniorarnaldogomes perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications
AT mavellarleticia perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications
AT cantunespaulof perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications
AT pontesmariaj perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications
AT marquescarlosa perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications
AT frizeraanselmo perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications
AT nribeiromoisesr perrogatoraportableenergyefficientinterrogatorfordynamicmonitoringofwavelengthbasedsensorsinwearableapplications