Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load

This work investigates and improves the thermal dynamics of autoclaved aerated concrete (AAC) wall containing phase change material (PCM). The PCM is paraffin wax loaded into conical holes drilled into the AAC. Filled AAC with three different numbers of PCM-filled holes (2, 3, and 4 conical holes, w...

Descripción completa

Detalles Bibliográficos
Autores principales: Thongtha, Atthakorn, Khongthon, Aitthi, Boonsri, Thitinun, Hoy-Yen, Chan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651643/
https://www.ncbi.nlm.nih.gov/pubmed/31284543
http://dx.doi.org/10.3390/ma12132170
_version_ 1783438395088830464
author Thongtha, Atthakorn
Khongthon, Aitthi
Boonsri, Thitinun
Hoy-Yen, Chan
author_facet Thongtha, Atthakorn
Khongthon, Aitthi
Boonsri, Thitinun
Hoy-Yen, Chan
author_sort Thongtha, Atthakorn
collection PubMed
description This work investigates and improves the thermal dynamics of autoclaved aerated concrete (AAC) wall containing phase change material (PCM). The PCM is paraffin wax loaded into conical holes drilled into the AAC. Filled AAC with three different numbers of PCM-filled holes (2, 3, and 4 conical holes, which are designated as AAC-2H, AAC-3H, and AAC-4H, respectively) as well as the unfilled original AAC were both tested under two different conditions: indoors (with controlled temperature) and outdoors (with actual weather). For the indoor experiment, a heater was used as a thermal source and set up to maintain the testing temperature at one of three levels: 40 °C, 50 °C, or 60 °C. The wall temperature was then measured on the surface with each horizontally-positioned wall as well as four different positions at various depths below the surface of the wall. It was found that AAC-4H was the optimum condition, which can produce outstandingly a time lag of approximately 27%, reduce a decrement factor of approximately 31%, and also decrease the room temperature. This reached approximately 9% when compared with that of ordinary AAC at the controlled testing temperature of 60 °C. All samples were further tested in actual weather to confirm the thermal performances of AAC-4H. Thermal effectiveness of AAC-4H was improved by extending approximately a 14.3% time lag, which reduces approximately a 4.3% decrement factor and achieving approximately 5% lower room temperature when compared with ordinary AAC.
format Online
Article
Text
id pubmed-6651643
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66516432019-08-08 Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load Thongtha, Atthakorn Khongthon, Aitthi Boonsri, Thitinun Hoy-Yen, Chan Materials (Basel) Article This work investigates and improves the thermal dynamics of autoclaved aerated concrete (AAC) wall containing phase change material (PCM). The PCM is paraffin wax loaded into conical holes drilled into the AAC. Filled AAC with three different numbers of PCM-filled holes (2, 3, and 4 conical holes, which are designated as AAC-2H, AAC-3H, and AAC-4H, respectively) as well as the unfilled original AAC were both tested under two different conditions: indoors (with controlled temperature) and outdoors (with actual weather). For the indoor experiment, a heater was used as a thermal source and set up to maintain the testing temperature at one of three levels: 40 °C, 50 °C, or 60 °C. The wall temperature was then measured on the surface with each horizontally-positioned wall as well as four different positions at various depths below the surface of the wall. It was found that AAC-4H was the optimum condition, which can produce outstandingly a time lag of approximately 27%, reduce a decrement factor of approximately 31%, and also decrease the room temperature. This reached approximately 9% when compared with that of ordinary AAC at the controlled testing temperature of 60 °C. All samples were further tested in actual weather to confirm the thermal performances of AAC-4H. Thermal effectiveness of AAC-4H was improved by extending approximately a 14.3% time lag, which reduces approximately a 4.3% decrement factor and achieving approximately 5% lower room temperature when compared with ordinary AAC. MDPI 2019-07-06 /pmc/articles/PMC6651643/ /pubmed/31284543 http://dx.doi.org/10.3390/ma12132170 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Thongtha, Atthakorn
Khongthon, Aitthi
Boonsri, Thitinun
Hoy-Yen, Chan
Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load
title Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load
title_full Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load
title_fullStr Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load
title_full_unstemmed Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load
title_short Thermal Effectiveness Enhancement of Autoclaved Aerated Concrete Wall with PCM-Contained Conical Holes to Reduce the Cooling Load
title_sort thermal effectiveness enhancement of autoclaved aerated concrete wall with pcm-contained conical holes to reduce the cooling load
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651643/
https://www.ncbi.nlm.nih.gov/pubmed/31284543
http://dx.doi.org/10.3390/ma12132170
work_keys_str_mv AT thongthaatthakorn thermaleffectivenessenhancementofautoclavedaeratedconcretewallwithpcmcontainedconicalholestoreducethecoolingload
AT khongthonaitthi thermaleffectivenessenhancementofautoclavedaeratedconcretewallwithpcmcontainedconicalholestoreducethecoolingload
AT boonsrithitinun thermaleffectivenessenhancementofautoclavedaeratedconcretewallwithpcmcontainedconicalholestoreducethecoolingload
AT hoyyenchan thermaleffectivenessenhancementofautoclavedaeratedconcretewallwithpcmcontainedconicalholestoreducethecoolingload