Cargando…

Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation

Theoretically, by controlling neural membrane potential (V(m)) in vivo, motion, sensation, and behavior can be controlled. Until now, there was no available technique that can increase or decrease ion concentration in vivo in real time to change neural membrane potential. We introduce a method that...

Descripción completa

Detalles Bibliográficos
Autores principales: Soybaş, Zafer, Şimşek, Sefa, Erol, F.M. Betül, Erdoğan, U. Çiya, Şimşek, Esra N., Şahin, Büşra, Marçalı, Merve, Aydoğdu, Bahattin, Elbüken, Çağlar, Melik, Rohat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651852/
https://www.ncbi.nlm.nih.gov/pubmed/31326701
http://dx.doi.org/10.1016/j.isci.2019.06.038
_version_ 1783438440696643584
author Soybaş, Zafer
Şimşek, Sefa
Erol, F.M. Betül
Erdoğan, U. Çiya
Şimşek, Esra N.
Şahin, Büşra
Marçalı, Merve
Aydoğdu, Bahattin
Elbüken, Çağlar
Melik, Rohat
author_facet Soybaş, Zafer
Şimşek, Sefa
Erol, F.M. Betül
Erdoğan, U. Çiya
Şimşek, Esra N.
Şahin, Büşra
Marçalı, Merve
Aydoğdu, Bahattin
Elbüken, Çağlar
Melik, Rohat
author_sort Soybaş, Zafer
collection PubMed
description Theoretically, by controlling neural membrane potential (V(m)) in vivo, motion, sensation, and behavior can be controlled. Until now, there was no available technique that can increase or decrease ion concentration in vivo in real time to change neural membrane potential. We introduce a method that we coin electro-ionic modulation (EIM), wherein ionic concentration around a nerve can be controlled in real time and in vivo. We used an interface to regulate the Ca(2+) ion concentration around the sciatic nerve of a frog and thus achieved stimulation and blocking with higher resolution and lower current compared with electrical stimulation. As EIM achieves higher controllability of V(m), it has potential to replace conventional methods used for the treatment of neurological disorders and may bring a new perspective to neuromodulation techniques.
format Online
Article
Text
id pubmed-6651852
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-66518522019-08-05 Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation Soybaş, Zafer Şimşek, Sefa Erol, F.M. Betül Erdoğan, U. Çiya Şimşek, Esra N. Şahin, Büşra Marçalı, Merve Aydoğdu, Bahattin Elbüken, Çağlar Melik, Rohat iScience Article Theoretically, by controlling neural membrane potential (V(m)) in vivo, motion, sensation, and behavior can be controlled. Until now, there was no available technique that can increase or decrease ion concentration in vivo in real time to change neural membrane potential. We introduce a method that we coin electro-ionic modulation (EIM), wherein ionic concentration around a nerve can be controlled in real time and in vivo. We used an interface to regulate the Ca(2+) ion concentration around the sciatic nerve of a frog and thus achieved stimulation and blocking with higher resolution and lower current compared with electrical stimulation. As EIM achieves higher controllability of V(m), it has potential to replace conventional methods used for the treatment of neurological disorders and may bring a new perspective to neuromodulation techniques. Elsevier 2019-07-05 /pmc/articles/PMC6651852/ /pubmed/31326701 http://dx.doi.org/10.1016/j.isci.2019.06.038 Text en © 2019 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Soybaş, Zafer
Şimşek, Sefa
Erol, F.M. Betül
Erdoğan, U. Çiya
Şimşek, Esra N.
Şahin, Büşra
Marçalı, Merve
Aydoğdu, Bahattin
Elbüken, Çağlar
Melik, Rohat
Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation
title Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation
title_full Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation
title_fullStr Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation
title_full_unstemmed Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation
title_short Real-Time In Vivo Control of Neural Membrane Potential by Electro-Ionic Modulation
title_sort real-time in vivo control of neural membrane potential by electro-ionic modulation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6651852/
https://www.ncbi.nlm.nih.gov/pubmed/31326701
http://dx.doi.org/10.1016/j.isci.2019.06.038
work_keys_str_mv AT soybaszafer realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT simseksefa realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT erolfmbetul realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT erdoganuciya realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT simsekesran realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT sahinbusra realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT marcalımerve realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT aydogdubahattin realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT elbukencaglar realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation
AT melikrohat realtimeinvivocontrolofneuralmembranepotentialbyelectroionicmodulation