Cargando…

Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases

INTRODUCTION: The aim of this study was to evaluate the intraoperative revision rate and reasons for revision following 3D imaging in the management of dislocated articular tibial plateau fractures based on a large patient sample. METHODS: This retrospective cohort study included all patients who un...

Descripción completa

Detalles Bibliográficos
Autores principales: Beisemann, Nils, Keil, Holger, Swartman, Benedict, Schnetzke, Marc, Franke, Jochen, Grützner, Paul Alfred, Vetter, Sven Y.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6657091/
https://www.ncbi.nlm.nih.gov/pubmed/31340818
http://dx.doi.org/10.1186/s13018-019-1286-7
_version_ 1783438742266052608
author Beisemann, Nils
Keil, Holger
Swartman, Benedict
Schnetzke, Marc
Franke, Jochen
Grützner, Paul Alfred
Vetter, Sven Y.
author_facet Beisemann, Nils
Keil, Holger
Swartman, Benedict
Schnetzke, Marc
Franke, Jochen
Grützner, Paul Alfred
Vetter, Sven Y.
author_sort Beisemann, Nils
collection PubMed
description INTRODUCTION: The aim of this study was to evaluate the intraoperative revision rate and reasons for revision following 3D imaging in the management of dislocated articular tibial plateau fractures based on a large patient sample. METHODS: This retrospective cohort study included all patients who underwent open reduction and internal fixation due type B or C tibial plateau fracture according to the AO/OTA classification between August 2001 and December 2017 using intraoperative cone beam CT (3D imaging) for the analysis of fracture reduction and implant placement. The findings of the 3D scan were categorized regarding the amount and type of revision. Furthermore, demographic data was examined. RESULTS: Five hundred and fifty-nine consecutive fractures were included in the study. Evaluation of the image data records revealed an intraoperative revision due to the usage of 3D imaging in 148 out of 559 cases (26.5%). The most common reasons for an intraoperative revision were insufficient fracture reduction (114 cases) and screw length (21 cases). CONCLUSION: This study reveals indications for a limited analysis of fracture reduction and implant placement during the operative treatment of dislocated articular tibial plateau fractures using conventional fluoroscopy. In view of the high revision rate during open reduction and internal fixation of tibial plateau fractures due to 3D imaging the usage of intraoperative cone beam, CT may be considered. If this is not possible, a postoperative computed tomography may therefore be reasonable.
format Online
Article
Text
id pubmed-6657091
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66570912019-07-31 Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases Beisemann, Nils Keil, Holger Swartman, Benedict Schnetzke, Marc Franke, Jochen Grützner, Paul Alfred Vetter, Sven Y. J Orthop Surg Res Research Article INTRODUCTION: The aim of this study was to evaluate the intraoperative revision rate and reasons for revision following 3D imaging in the management of dislocated articular tibial plateau fractures based on a large patient sample. METHODS: This retrospective cohort study included all patients who underwent open reduction and internal fixation due type B or C tibial plateau fracture according to the AO/OTA classification between August 2001 and December 2017 using intraoperative cone beam CT (3D imaging) for the analysis of fracture reduction and implant placement. The findings of the 3D scan were categorized regarding the amount and type of revision. Furthermore, demographic data was examined. RESULTS: Five hundred and fifty-nine consecutive fractures were included in the study. Evaluation of the image data records revealed an intraoperative revision due to the usage of 3D imaging in 148 out of 559 cases (26.5%). The most common reasons for an intraoperative revision were insufficient fracture reduction (114 cases) and screw length (21 cases). CONCLUSION: This study reveals indications for a limited analysis of fracture reduction and implant placement during the operative treatment of dislocated articular tibial plateau fractures using conventional fluoroscopy. In view of the high revision rate during open reduction and internal fixation of tibial plateau fractures due to 3D imaging the usage of intraoperative cone beam, CT may be considered. If this is not possible, a postoperative computed tomography may therefore be reasonable. BioMed Central 2019-07-24 /pmc/articles/PMC6657091/ /pubmed/31340818 http://dx.doi.org/10.1186/s13018-019-1286-7 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Beisemann, Nils
Keil, Holger
Swartman, Benedict
Schnetzke, Marc
Franke, Jochen
Grützner, Paul Alfred
Vetter, Sven Y.
Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases
title Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases
title_full Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases
title_fullStr Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases
title_full_unstemmed Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases
title_short Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases
title_sort intraoperative 3d imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6657091/
https://www.ncbi.nlm.nih.gov/pubmed/31340818
http://dx.doi.org/10.1186/s13018-019-1286-7
work_keys_str_mv AT beisemannnils intraoperative3dimagingleadstosubstantialrevisionrateinmanagementoftibialplateaufracturesin559cases
AT keilholger intraoperative3dimagingleadstosubstantialrevisionrateinmanagementoftibialplateaufracturesin559cases
AT swartmanbenedict intraoperative3dimagingleadstosubstantialrevisionrateinmanagementoftibialplateaufracturesin559cases
AT schnetzkemarc intraoperative3dimagingleadstosubstantialrevisionrateinmanagementoftibialplateaufracturesin559cases
AT frankejochen intraoperative3dimagingleadstosubstantialrevisionrateinmanagementoftibialplateaufracturesin559cases
AT grutznerpaulalfred intraoperative3dimagingleadstosubstantialrevisionrateinmanagementoftibialplateaufracturesin559cases
AT vettersveny intraoperative3dimagingleadstosubstantialrevisionrateinmanagementoftibialplateaufracturesin559cases