Cargando…

Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study

BACKGROUND: Over the past several decades, naturally occurring and man-made mass casualty incidents (MCIs) have increased in frequency and number worldwide. To test the impact of such events on medical resources, simulations can provide a safe, controlled setting while replicating the chaotic enviro...

Descripción completa

Detalles Bibliográficos
Autores principales: Ozella, Laura, Gauvin, Laetitia, Carenzo, Luca, Quaggiotto, Marco, Ingrassia, Pier Luigi, Tizzoni, Michele, Panisson, André, Colombo, Davide, Sapienza, Anna, Kalimeri, Kyriaki, Della Corte, Francesco, Cattuto, Ciro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6658323/
https://www.ncbi.nlm.nih.gov/pubmed/31025944
http://dx.doi.org/10.2196/12251
_version_ 1783438948200087552
author Ozella, Laura
Gauvin, Laetitia
Carenzo, Luca
Quaggiotto, Marco
Ingrassia, Pier Luigi
Tizzoni, Michele
Panisson, André
Colombo, Davide
Sapienza, Anna
Kalimeri, Kyriaki
Della Corte, Francesco
Cattuto, Ciro
author_facet Ozella, Laura
Gauvin, Laetitia
Carenzo, Luca
Quaggiotto, Marco
Ingrassia, Pier Luigi
Tizzoni, Michele
Panisson, André
Colombo, Davide
Sapienza, Anna
Kalimeri, Kyriaki
Della Corte, Francesco
Cattuto, Ciro
author_sort Ozella, Laura
collection PubMed
description BACKGROUND: Over the past several decades, naturally occurring and man-made mass casualty incidents (MCIs) have increased in frequency and number worldwide. To test the impact of such events on medical resources, simulations can provide a safe, controlled setting while replicating the chaotic environment typical of an actual disaster. A standardized method to collect and analyze data from mass casualty exercises is needed to assess preparedness and performance of the health care staff involved. OBJECTIVE: In this study, we aimed to assess the feasibility of using wearable proximity sensors to measure proximity events during an MCI simulation. In the first instance, our objective was to demonstrate how proximity sensors can collect spatial and temporal information about the interactions between medical staff and patients during an MCI exercise in a quasi-autonomous way. In addition, we assessed how the deployment of this technology could help improve future simulations by analyzing the flow of patients in the hospital. METHODS: Data were obtained and collected through the deployment of wearable proximity sensors during an MCI functional exercise. The scenario included 2 areas: the accident site and the Advanced Medical Post, and the exercise lasted 3 hours. A total of 238 participants were involved in the exercise and classified in categories according to their role: 14 medical doctors, 16 nurses, 134 victims, 47 Emergency Medical Services staff members, and 27 health care assistants and other hospital support staff. Each victim was assigned a score related to the severity of his/her injury. Each participant wore a proximity sensor, and in addition, 30 fixed devices were placed in the field hospital. RESULTS: The contact networks show a heterogeneous distribution of the cumulative time spent in proximity by the participants. We obtained contact matrices based on the cumulative time spent in proximity between the victims and rescuers. Our results showed that the time spent in proximity by the health care teams with the victims is related to the severity of the patient’s injury. The analysis of patients’ flow showed that the presence of patients in the rooms of the hospital is consistent with the triage code and diagnosis, and no obvious bottlenecks were found. CONCLUSIONS: Our study shows the feasibility of the use of wearable sensors for tracking close contacts among individuals during an MCI simulation. It represents, to our knowledge, the first example of unsupervised data collection—ie, without the need for the involvement of observers, which could compromise the realism of the exercise—of face-to-face contacts during an MCI exercise. Moreover, by permitting detailed data collection about the simulation, such as data related to the flow of patients in the hospital, such deployment provides highly relevant input for the improvement of MCI resource allocation and management.
format Online
Article
Text
id pubmed-6658323
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher JMIR Publications
record_format MEDLINE/PubMed
spelling pubmed-66583232019-07-31 Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study Ozella, Laura Gauvin, Laetitia Carenzo, Luca Quaggiotto, Marco Ingrassia, Pier Luigi Tizzoni, Michele Panisson, André Colombo, Davide Sapienza, Anna Kalimeri, Kyriaki Della Corte, Francesco Cattuto, Ciro J Med Internet Res Original Paper BACKGROUND: Over the past several decades, naturally occurring and man-made mass casualty incidents (MCIs) have increased in frequency and number worldwide. To test the impact of such events on medical resources, simulations can provide a safe, controlled setting while replicating the chaotic environment typical of an actual disaster. A standardized method to collect and analyze data from mass casualty exercises is needed to assess preparedness and performance of the health care staff involved. OBJECTIVE: In this study, we aimed to assess the feasibility of using wearable proximity sensors to measure proximity events during an MCI simulation. In the first instance, our objective was to demonstrate how proximity sensors can collect spatial and temporal information about the interactions between medical staff and patients during an MCI exercise in a quasi-autonomous way. In addition, we assessed how the deployment of this technology could help improve future simulations by analyzing the flow of patients in the hospital. METHODS: Data were obtained and collected through the deployment of wearable proximity sensors during an MCI functional exercise. The scenario included 2 areas: the accident site and the Advanced Medical Post, and the exercise lasted 3 hours. A total of 238 participants were involved in the exercise and classified in categories according to their role: 14 medical doctors, 16 nurses, 134 victims, 47 Emergency Medical Services staff members, and 27 health care assistants and other hospital support staff. Each victim was assigned a score related to the severity of his/her injury. Each participant wore a proximity sensor, and in addition, 30 fixed devices were placed in the field hospital. RESULTS: The contact networks show a heterogeneous distribution of the cumulative time spent in proximity by the participants. We obtained contact matrices based on the cumulative time spent in proximity between the victims and rescuers. Our results showed that the time spent in proximity by the health care teams with the victims is related to the severity of the patient’s injury. The analysis of patients’ flow showed that the presence of patients in the rooms of the hospital is consistent with the triage code and diagnosis, and no obvious bottlenecks were found. CONCLUSIONS: Our study shows the feasibility of the use of wearable sensors for tracking close contacts among individuals during an MCI simulation. It represents, to our knowledge, the first example of unsupervised data collection—ie, without the need for the involvement of observers, which could compromise the realism of the exercise—of face-to-face contacts during an MCI exercise. Moreover, by permitting detailed data collection about the simulation, such as data related to the flow of patients in the hospital, such deployment provides highly relevant input for the improvement of MCI resource allocation and management. JMIR Publications 2019-04-26 /pmc/articles/PMC6658323/ /pubmed/31025944 http://dx.doi.org/10.2196/12251 Text en ©Laura Ozella, Laetitia Gauvin, Luca Carenzo, Marco Quaggiotto, Pier Luigi Ingrassia, Michele Tizzoni, André Panisson, Davide Colombo, Anna Sapienza, Kyriaki Kalimeri, Francesco Della Corte, Ciro Cattuto. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 26.04.2019. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on http://www.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Ozella, Laura
Gauvin, Laetitia
Carenzo, Luca
Quaggiotto, Marco
Ingrassia, Pier Luigi
Tizzoni, Michele
Panisson, André
Colombo, Davide
Sapienza, Anna
Kalimeri, Kyriaki
Della Corte, Francesco
Cattuto, Ciro
Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study
title Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study
title_full Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study
title_fullStr Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study
title_full_unstemmed Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study
title_short Wearable Proximity Sensors for Monitoring a Mass Casualty Incident Exercise: Feasibility Study
title_sort wearable proximity sensors for monitoring a mass casualty incident exercise: feasibility study
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6658323/
https://www.ncbi.nlm.nih.gov/pubmed/31025944
http://dx.doi.org/10.2196/12251
work_keys_str_mv AT ozellalaura wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT gauvinlaetitia wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT carenzoluca wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT quaggiottomarco wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT ingrassiapierluigi wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT tizzonimichele wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT panissonandre wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT colombodavide wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT sapienzaanna wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT kalimerikyriaki wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT dellacortefrancesco wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy
AT cattutociro wearableproximitysensorsformonitoringamasscasualtyincidentexercisefeasibilitystudy