Cargando…

Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility

BACKGROUND: Magnetic resonance enterography (MRE) is increasingly attractive as a noninvasive and radiation-free tool for assessing Crohn’s disease (CD). Diffusion-weighted imaging (DWI) is recommended as an optional MRE sequence for CD by the European Society of Gastrointestinal and Abdominal Radio...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Hao, Shen, Ya-Qi, Tan, Fang-Qin, Zhou, Zi-Ling, Li, Zhen, Hu, Dao-Yu, Morelli, John N
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6658399/
https://www.ncbi.nlm.nih.gov/pubmed/31367161
http://dx.doi.org/10.3748/wjg.v25.i27.3619
_version_ 1783438958543241216
author Yu, Hao
Shen, Ya-Qi
Tan, Fang-Qin
Zhou, Zi-Ling
Li, Zhen
Hu, Dao-Yu
Morelli, John N
author_facet Yu, Hao
Shen, Ya-Qi
Tan, Fang-Qin
Zhou, Zi-Ling
Li, Zhen
Hu, Dao-Yu
Morelli, John N
author_sort Yu, Hao
collection PubMed
description BACKGROUND: Magnetic resonance enterography (MRE) is increasingly attractive as a noninvasive and radiation-free tool for assessing Crohn’s disease (CD). Diffusion-weighted imaging (DWI) is recommended as an optional MRE sequence for CD by the European Society of Gastrointestinal and Abdominal Radiology, and has shown a superb potential as a quantitative modality for bowel inflammation evaluation. However, the measurement reproducibility of quantitative DWI analysis in MRE has not been ascertained so far. To facilitate the application of quantitative diffusion-weighted MRE in the clinical routine, systematic investigations of the intra and interobserver reproducibility of DWI quantitative parameters should be performed. AIM: To evaluate the intra and interobserver reproducibility of quantitative analysis for diffusion-weighted MRE (DW-MRE) in ileal CD. METHODS: Forty-four subjects (21 with CD and 23 control subjects) who underwent ileocolonoscopy and DW-MRE (b = 800 s/mm(2)) within one week were included. Two radiologists independently measured apparent diffusion coefficients (ADC) of the terminal ileum and signal intensity ratio (SR) of the terminal ileum to ipsilateral psoas muscle on DWI images (b = 800 s/mm(2)). Between- and within-reader agreements were assessed using intraclass correlation coefficients (ICC), coefficients of variation (CoV), and 95% limits of agreement of Bland-Altman plots (BA-LA LoA). Diagnostic performances of ADC and SR for identifying inflamed terminal ileum from the normal were evaluated by receiver operating characteristic (ROC) curve analysis. RESULTS: There were no significant differences in ADC or SR values between the two sessions or between the two radiologists either in the CD or control group (paired t-test, P > 0.05). The intra and interobserver reproducibility of ADC (ICC: 0.952-0.984; CoV: 3.73-6.28%; BA-LA LoA: ±11.27% to ±15.88%) and SR (ICC: 0.969-0.989; CoV: 3.51%-4.64%; BA-LA LoA: ±10.62% to ±15.45%) was excellent for CD. Agreement of ADC measurements was slightly less in control subjects (ICC: 0.641-0.736; CoV: 10.47%-11.43%; BA-LA LoA: ± 26.59% to ± 30.83%). SR of normal terminal ileum demonstrated high intra and interobserver reproducibility (ICC: 0.944-0.974; CoV: 3.73%-6.28%; BA-LA LoA: ± 18.58% to ± 24.43%). ADC and SR of two readers had outstanding diagnostic efficiencies (area under the ROC curve: 0.923-0.988). CONCLUSION: Quantitative parameters derived from DW-MRE have good to excellent intra and interobserver agreements with high diagnostic accuracy, and can serve as robust and efficient quantitative biomarkers for CD evaluation.
format Online
Article
Text
id pubmed-6658399
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-66583992019-07-31 Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility Yu, Hao Shen, Ya-Qi Tan, Fang-Qin Zhou, Zi-Ling Li, Zhen Hu, Dao-Yu Morelli, John N World J Gastroenterol Retrospective Study BACKGROUND: Magnetic resonance enterography (MRE) is increasingly attractive as a noninvasive and radiation-free tool for assessing Crohn’s disease (CD). Diffusion-weighted imaging (DWI) is recommended as an optional MRE sequence for CD by the European Society of Gastrointestinal and Abdominal Radiology, and has shown a superb potential as a quantitative modality for bowel inflammation evaluation. However, the measurement reproducibility of quantitative DWI analysis in MRE has not been ascertained so far. To facilitate the application of quantitative diffusion-weighted MRE in the clinical routine, systematic investigations of the intra and interobserver reproducibility of DWI quantitative parameters should be performed. AIM: To evaluate the intra and interobserver reproducibility of quantitative analysis for diffusion-weighted MRE (DW-MRE) in ileal CD. METHODS: Forty-four subjects (21 with CD and 23 control subjects) who underwent ileocolonoscopy and DW-MRE (b = 800 s/mm(2)) within one week were included. Two radiologists independently measured apparent diffusion coefficients (ADC) of the terminal ileum and signal intensity ratio (SR) of the terminal ileum to ipsilateral psoas muscle on DWI images (b = 800 s/mm(2)). Between- and within-reader agreements were assessed using intraclass correlation coefficients (ICC), coefficients of variation (CoV), and 95% limits of agreement of Bland-Altman plots (BA-LA LoA). Diagnostic performances of ADC and SR for identifying inflamed terminal ileum from the normal were evaluated by receiver operating characteristic (ROC) curve analysis. RESULTS: There were no significant differences in ADC or SR values between the two sessions or between the two radiologists either in the CD or control group (paired t-test, P > 0.05). The intra and interobserver reproducibility of ADC (ICC: 0.952-0.984; CoV: 3.73-6.28%; BA-LA LoA: ±11.27% to ±15.88%) and SR (ICC: 0.969-0.989; CoV: 3.51%-4.64%; BA-LA LoA: ±10.62% to ±15.45%) was excellent for CD. Agreement of ADC measurements was slightly less in control subjects (ICC: 0.641-0.736; CoV: 10.47%-11.43%; BA-LA LoA: ± 26.59% to ± 30.83%). SR of normal terminal ileum demonstrated high intra and interobserver reproducibility (ICC: 0.944-0.974; CoV: 3.73%-6.28%; BA-LA LoA: ± 18.58% to ± 24.43%). ADC and SR of two readers had outstanding diagnostic efficiencies (area under the ROC curve: 0.923-0.988). CONCLUSION: Quantitative parameters derived from DW-MRE have good to excellent intra and interobserver agreements with high diagnostic accuracy, and can serve as robust and efficient quantitative biomarkers for CD evaluation. Baishideng Publishing Group Inc 2019-07-21 2019-07-21 /pmc/articles/PMC6658399/ /pubmed/31367161 http://dx.doi.org/10.3748/wjg.v25.i27.3619 Text en ©The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Retrospective Study
Yu, Hao
Shen, Ya-Qi
Tan, Fang-Qin
Zhou, Zi-Ling
Li, Zhen
Hu, Dao-Yu
Morelli, John N
Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility
title Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility
title_full Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility
title_fullStr Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility
title_full_unstemmed Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility
title_short Quantitative diffusion-weighted magnetic resonance enterography in ileal Crohn's disease: A systematic analysis of intra and interobserver reproducibility
title_sort quantitative diffusion-weighted magnetic resonance enterography in ileal crohn's disease: a systematic analysis of intra and interobserver reproducibility
topic Retrospective Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6658399/
https://www.ncbi.nlm.nih.gov/pubmed/31367161
http://dx.doi.org/10.3748/wjg.v25.i27.3619
work_keys_str_mv AT yuhao quantitativediffusionweightedmagneticresonanceenterographyinilealcrohnsdiseaseasystematicanalysisofintraandinterobserverreproducibility
AT shenyaqi quantitativediffusionweightedmagneticresonanceenterographyinilealcrohnsdiseaseasystematicanalysisofintraandinterobserverreproducibility
AT tanfangqin quantitativediffusionweightedmagneticresonanceenterographyinilealcrohnsdiseaseasystematicanalysisofintraandinterobserverreproducibility
AT zhouziling quantitativediffusionweightedmagneticresonanceenterographyinilealcrohnsdiseaseasystematicanalysisofintraandinterobserverreproducibility
AT lizhen quantitativediffusionweightedmagneticresonanceenterographyinilealcrohnsdiseaseasystematicanalysisofintraandinterobserverreproducibility
AT hudaoyu quantitativediffusionweightedmagneticresonanceenterographyinilealcrohnsdiseaseasystematicanalysisofintraandinterobserverreproducibility
AT morellijohnn quantitativediffusionweightedmagneticresonanceenterographyinilealcrohnsdiseaseasystematicanalysisofintraandinterobserverreproducibility