Cargando…

Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation

INTRODUCTION: Cardiac tamponade is a rare but life-threatening complication during atrial fibrillation (AF) catheter ablation. Contact force (CF)–sensing catheters improve ablation effectiveness. However, the impact of the application of CF-sensing catheters on the occurrence of cardiac tamponade re...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Nian, Zhao, Qianqian, Li, Linling, Zhang, Mengxia, Huang, Jiao, Wei, Sheng, Wen, Songnan, Ruan, Yanfei, Guo, Xueyuan, Li, Songnan, Jiang, Chengxi, Tang, Ribo, Sang, Caihua, Long, Deyong, Yu, Ronghui, Bai, Rong, Du, Xin, Dong, Jianzeng, Ma, Changsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6660577/
https://www.ncbi.nlm.nih.gov/pubmed/30712075
http://dx.doi.org/10.1007/s10840-019-00516-z
_version_ 1783439325974757376
author Liu, Nian
Zhao, Qianqian
Li, Linling
Zhang, Mengxia
Huang, Jiao
Wei, Sheng
Wen, Songnan
Ruan, Yanfei
Guo, Xueyuan
Li, Songnan
Jiang, Chengxi
Tang, Ribo
Sang, Caihua
Long, Deyong
Yu, Ronghui
Bai, Rong
Du, Xin
Dong, Jianzeng
Ma, Changsheng
author_facet Liu, Nian
Zhao, Qianqian
Li, Linling
Zhang, Mengxia
Huang, Jiao
Wei, Sheng
Wen, Songnan
Ruan, Yanfei
Guo, Xueyuan
Li, Songnan
Jiang, Chengxi
Tang, Ribo
Sang, Caihua
Long, Deyong
Yu, Ronghui
Bai, Rong
Du, Xin
Dong, Jianzeng
Ma, Changsheng
author_sort Liu, Nian
collection PubMed
description INTRODUCTION: Cardiac tamponade is a rare but life-threatening complication during atrial fibrillation (AF) catheter ablation. Contact force (CF)–sensing catheters improve ablation effectiveness. However, the impact of the application of CF-sensing catheters on the occurrence of cardiac tamponade remains unclear. The aim of this study is to evaluate the “real-world” impact of CF-sensing catheters on cardiac tamponade during AF ablation in an experienced medical center. METHODS AND RESULTS: This was a retrospective study of consecutive de novo AF ablation procedures at Beijing Anzhen Hospital between 2013 and 2016. The ablation procedure was divided into a CF group and a non-CF group. Logistic regression analysis was used to evaluate the association between the use of CF-sensing catheters and the risk of cardiac tamponade. A total of 5313 patients with AF were involved in this study. The incidence of cardiac tamponade in the CF group was significantly higher than that in the non-CF group (1.07% vs. 0.44%, P = 0.009). Of the cardiac tamponade cases in the non-CF group, 45.45% were delayed compared with 10% in the CF group (P = 0.011). Multivariate logistic regression analysis showed that CF-sensing catheters increased the risk of cardiac tamponade (OR = 2.34, 95% CI = 1.17–4.26, P = 0.015). Stratified analysis revealed patients with a smaller left atrium dimension, lower ejection fraction, longer procedure duration, or longer ablation duration had a greater risk of cardiac tamponade during ablation with CF-sensing catheters. CONCLUSIONS: CF-sensing catheters increase the risk of cardiac tamponade during AF ablation. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10840-019-00516-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6660577
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-66605772019-08-07 Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation Liu, Nian Zhao, Qianqian Li, Linling Zhang, Mengxia Huang, Jiao Wei, Sheng Wen, Songnan Ruan, Yanfei Guo, Xueyuan Li, Songnan Jiang, Chengxi Tang, Ribo Sang, Caihua Long, Deyong Yu, Ronghui Bai, Rong Du, Xin Dong, Jianzeng Ma, Changsheng J Interv Card Electrophysiol Multimedia Report INTRODUCTION: Cardiac tamponade is a rare but life-threatening complication during atrial fibrillation (AF) catheter ablation. Contact force (CF)–sensing catheters improve ablation effectiveness. However, the impact of the application of CF-sensing catheters on the occurrence of cardiac tamponade remains unclear. The aim of this study is to evaluate the “real-world” impact of CF-sensing catheters on cardiac tamponade during AF ablation in an experienced medical center. METHODS AND RESULTS: This was a retrospective study of consecutive de novo AF ablation procedures at Beijing Anzhen Hospital between 2013 and 2016. The ablation procedure was divided into a CF group and a non-CF group. Logistic regression analysis was used to evaluate the association between the use of CF-sensing catheters and the risk of cardiac tamponade. A total of 5313 patients with AF were involved in this study. The incidence of cardiac tamponade in the CF group was significantly higher than that in the non-CF group (1.07% vs. 0.44%, P = 0.009). Of the cardiac tamponade cases in the non-CF group, 45.45% were delayed compared with 10% in the CF group (P = 0.011). Multivariate logistic regression analysis showed that CF-sensing catheters increased the risk of cardiac tamponade (OR = 2.34, 95% CI = 1.17–4.26, P = 0.015). Stratified analysis revealed patients with a smaller left atrium dimension, lower ejection fraction, longer procedure duration, or longer ablation duration had a greater risk of cardiac tamponade during ablation with CF-sensing catheters. CONCLUSIONS: CF-sensing catheters increase the risk of cardiac tamponade during AF ablation. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s10840-019-00516-z) contains supplementary material, which is available to authorized users. Springer US 2019-02-02 2019 /pmc/articles/PMC6660577/ /pubmed/30712075 http://dx.doi.org/10.1007/s10840-019-00516-z Text en © Springer Science+Business Media, LLC, part of Springer Nature 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Multimedia Report
Liu, Nian
Zhao, Qianqian
Li, Linling
Zhang, Mengxia
Huang, Jiao
Wei, Sheng
Wen, Songnan
Ruan, Yanfei
Guo, Xueyuan
Li, Songnan
Jiang, Chengxi
Tang, Ribo
Sang, Caihua
Long, Deyong
Yu, Ronghui
Bai, Rong
Du, Xin
Dong, Jianzeng
Ma, Changsheng
Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
title Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
title_full Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
title_fullStr Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
title_full_unstemmed Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
title_short Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
title_sort association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
topic Multimedia Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6660577/
https://www.ncbi.nlm.nih.gov/pubmed/30712075
http://dx.doi.org/10.1007/s10840-019-00516-z
work_keys_str_mv AT liunian associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT zhaoqianqian associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT lilinling associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT zhangmengxia associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT huangjiao associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT weisheng associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT wensongnan associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT ruanyanfei associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT guoxueyuan associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT lisongnan associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT jiangchengxi associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT tangribo associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT sangcaihua associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT longdeyong associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT yuronghui associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT bairong associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT duxin associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT dongjianzeng associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation
AT machangsheng associationbetweentheuseofcontactforcesensingcathetersandcardiactamponadeinatrialfibrillationablation