Cargando…

Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference

BACKGROUND: The reliable quantification of myocardial blood flow (MBF) with MRI, necessitates the correction of errors in arterial input function (AIF) caused by the T1 saturation effect. The aim of this study was to compare MBF determined by a traditional dual bolus method against a modified dual b...

Descripción completa

Detalles Bibliográficos
Autores principales: Husso, Minna, Nissi, Mikko J., Kuivanen, Antti, Halonen, Paavo, Tarkia, Miikka, Teuho, Jarmo, Saunavaara, Virva, Vainio, Pauli, Sipola, Petri, Manninen, Hannu, Ylä-Herttuala, Seppo, Knuuti, Juhani, Töyräs, Juha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6660956/
https://www.ncbi.nlm.nih.gov/pubmed/31349798
http://dx.doi.org/10.1186/s12880-019-0359-8
_version_ 1783439390676090880
author Husso, Minna
Nissi, Mikko J.
Kuivanen, Antti
Halonen, Paavo
Tarkia, Miikka
Teuho, Jarmo
Saunavaara, Virva
Vainio, Pauli
Sipola, Petri
Manninen, Hannu
Ylä-Herttuala, Seppo
Knuuti, Juhani
Töyräs, Juha
author_facet Husso, Minna
Nissi, Mikko J.
Kuivanen, Antti
Halonen, Paavo
Tarkia, Miikka
Teuho, Jarmo
Saunavaara, Virva
Vainio, Pauli
Sipola, Petri
Manninen, Hannu
Ylä-Herttuala, Seppo
Knuuti, Juhani
Töyräs, Juha
author_sort Husso, Minna
collection PubMed
description BACKGROUND: The reliable quantification of myocardial blood flow (MBF) with MRI, necessitates the correction of errors in arterial input function (AIF) caused by the T1 saturation effect. The aim of this study was to compare MBF determined by a traditional dual bolus method against a modified dual bolus approach and to evaluate both methods against PET in a porcine model of myocardial ischemia. METHODS: Local myocardial ischemia was induced in five pigs, which were subsequently examined with contrast enhanced MRI (gadoteric acid) and PET (O-15 water). In the determination of MBF, the initial high concentration AIF was corrected using the ratio of low and high contrast AIF areas, normalized according to the corresponding heart rates. MBF was determined from the MRI, during stress and at rest, using the dual bolus and the modified dual bolus methods in 24 segments of the myocardium (total of 240 segments, five pigs in stress and rest). Due to image artifacts and technical problems 53% of the segments had to be rejected from further analyses. These two estimates were later compared against respective rest and stress PET-based MBF measurements. RESULTS: Values of MBF were determined for 112/240 regions. Correlations for MBF between the modified dual bolus method and PET was r(s) = 0.84, and between the traditional dual bolus method and PET r(s) = 0.79. The intraclass correlation was very good (ICC = 0.85) between the modified dual bolus method and PET, but poor between the traditional dual bolus method and PET (ICC = 0.07). CONCLUSIONS: The modified dual bolus method showed a better agreement with PET than the traditional dual bolus method. The modified dual bolus method was found to be more reliable than the traditional dual bolus method, especially when there was variation in the heart rate. However, the difference between the MBF values estimated with either of the two MRI-based dual-bolus methods and those estimated with the gold-standard PET method were statistically significant. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12880-019-0359-8) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6660956
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66609562019-08-01 Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference Husso, Minna Nissi, Mikko J. Kuivanen, Antti Halonen, Paavo Tarkia, Miikka Teuho, Jarmo Saunavaara, Virva Vainio, Pauli Sipola, Petri Manninen, Hannu Ylä-Herttuala, Seppo Knuuti, Juhani Töyräs, Juha BMC Med Imaging Research Article BACKGROUND: The reliable quantification of myocardial blood flow (MBF) with MRI, necessitates the correction of errors in arterial input function (AIF) caused by the T1 saturation effect. The aim of this study was to compare MBF determined by a traditional dual bolus method against a modified dual bolus approach and to evaluate both methods against PET in a porcine model of myocardial ischemia. METHODS: Local myocardial ischemia was induced in five pigs, which were subsequently examined with contrast enhanced MRI (gadoteric acid) and PET (O-15 water). In the determination of MBF, the initial high concentration AIF was corrected using the ratio of low and high contrast AIF areas, normalized according to the corresponding heart rates. MBF was determined from the MRI, during stress and at rest, using the dual bolus and the modified dual bolus methods in 24 segments of the myocardium (total of 240 segments, five pigs in stress and rest). Due to image artifacts and technical problems 53% of the segments had to be rejected from further analyses. These two estimates were later compared against respective rest and stress PET-based MBF measurements. RESULTS: Values of MBF were determined for 112/240 regions. Correlations for MBF between the modified dual bolus method and PET was r(s) = 0.84, and between the traditional dual bolus method and PET r(s) = 0.79. The intraclass correlation was very good (ICC = 0.85) between the modified dual bolus method and PET, but poor between the traditional dual bolus method and PET (ICC = 0.07). CONCLUSIONS: The modified dual bolus method showed a better agreement with PET than the traditional dual bolus method. The modified dual bolus method was found to be more reliable than the traditional dual bolus method, especially when there was variation in the heart rate. However, the difference between the MBF values estimated with either of the two MRI-based dual-bolus methods and those estimated with the gold-standard PET method were statistically significant. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12880-019-0359-8) contains supplementary material, which is available to authorized users. BioMed Central 2019-07-26 /pmc/articles/PMC6660956/ /pubmed/31349798 http://dx.doi.org/10.1186/s12880-019-0359-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Husso, Minna
Nissi, Mikko J.
Kuivanen, Antti
Halonen, Paavo
Tarkia, Miikka
Teuho, Jarmo
Saunavaara, Virva
Vainio, Pauli
Sipola, Petri
Manninen, Hannu
Ylä-Herttuala, Seppo
Knuuti, Juhani
Töyräs, Juha
Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference
title Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference
title_full Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference
title_fullStr Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference
title_full_unstemmed Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference
title_short Quantification of porcine myocardial perfusion with modified dual bolus MRI – a prospective study with a PET reference
title_sort quantification of porcine myocardial perfusion with modified dual bolus mri – a prospective study with a pet reference
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6660956/
https://www.ncbi.nlm.nih.gov/pubmed/31349798
http://dx.doi.org/10.1186/s12880-019-0359-8
work_keys_str_mv AT hussominna quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT nissimikkoj quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT kuivanenantti quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT halonenpaavo quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT tarkiamiikka quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT teuhojarmo quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT saunavaaravirva quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT vainiopauli quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT sipolapetri quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT manninenhannu quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT ylaherttualaseppo quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT knuutijuhani quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference
AT toyrasjuha quantificationofporcinemyocardialperfusionwithmodifieddualbolusmriaprospectivestudywithapetreference