Cargando…

Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets

Comtrex(®) tablets composed of paracetamol, pseudoephedrine and brompheniramine are widely used for relieving symptoms related to common cold. This study has overcome the challenging dosage form ratio (250:15:1) and proposed chromatographic methods for analyzing the ternary combination were utilized...

Descripción completa

Detalles Bibliográficos
Autores principales: Youssef, Souha Hosam, Mohamed, Dalia, Hegazy, Maha Abdel Monem, Badawey, Amr
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6661757/
https://www.ncbi.nlm.nih.gov/pubmed/31384825
http://dx.doi.org/10.1186/s13065-019-0595-6
_version_ 1783439518850875392
author Youssef, Souha Hosam
Mohamed, Dalia
Hegazy, Maha Abdel Monem
Badawey, Amr
author_facet Youssef, Souha Hosam
Mohamed, Dalia
Hegazy, Maha Abdel Monem
Badawey, Amr
author_sort Youssef, Souha Hosam
collection PubMed
description Comtrex(®) tablets composed of paracetamol, pseudoephedrine and brompheniramine are widely used for relieving symptoms related to common cold. This study has overcome the challenging dosage form ratio (250:15:1) and proposed chromatographic methods for analyzing the ternary combination were utilized displaying different apparatus, solvents and sensitivity ranges. Three chromatographic methods namely thin layer chromatography (TLC), high performance liquid chromatography with ultra-violet detection (HPLC–UV) and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) were developed and validated for the simultaneous determination of the three drugs. Concerning the TLC method, aluminum TLC plates pre-coated with silica gel 60F(254) were used and methanol:water:ammonia (9:1:0.1, v/v/v) was applied as a mobile phase; scanning of the plates was carried out at 254 nm. For the HPLC–UV method C(18) column was used with an isocratic elution mobile phase composed of water:acetonitrile (75:25, v/v; pH 3.2) and the detection was at 210 nm. For the UPLC-MS/MS method; separation was performed on a UPLC-BEH C(18) column with methanol: 0.1% ammonium formate (60:40, v/v) as the mobile phase utilizing diphenhydramine as an internal standard and mass spectrometry was used for detection. The methods were simple, sensitive, accurate and precise. Statistical analysis revealed no significant difference from the reported methods in regard to accuracy and precision. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13065-019-0595-6) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6661757
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-66617572019-08-05 Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets Youssef, Souha Hosam Mohamed, Dalia Hegazy, Maha Abdel Monem Badawey, Amr BMC Chem Research Article Comtrex(®) tablets composed of paracetamol, pseudoephedrine and brompheniramine are widely used for relieving symptoms related to common cold. This study has overcome the challenging dosage form ratio (250:15:1) and proposed chromatographic methods for analyzing the ternary combination were utilized displaying different apparatus, solvents and sensitivity ranges. Three chromatographic methods namely thin layer chromatography (TLC), high performance liquid chromatography with ultra-violet detection (HPLC–UV) and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) were developed and validated for the simultaneous determination of the three drugs. Concerning the TLC method, aluminum TLC plates pre-coated with silica gel 60F(254) were used and methanol:water:ammonia (9:1:0.1, v/v/v) was applied as a mobile phase; scanning of the plates was carried out at 254 nm. For the HPLC–UV method C(18) column was used with an isocratic elution mobile phase composed of water:acetonitrile (75:25, v/v; pH 3.2) and the detection was at 210 nm. For the UPLC-MS/MS method; separation was performed on a UPLC-BEH C(18) column with methanol: 0.1% ammonium formate (60:40, v/v) as the mobile phase utilizing diphenhydramine as an internal standard and mass spectrometry was used for detection. The methods were simple, sensitive, accurate and precise. Statistical analysis revealed no significant difference from the reported methods in regard to accuracy and precision. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13065-019-0595-6) contains supplementary material, which is available to authorized users. Springer International Publishing 2019-07-02 /pmc/articles/PMC6661757/ /pubmed/31384825 http://dx.doi.org/10.1186/s13065-019-0595-6 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Youssef, Souha Hosam
Mohamed, Dalia
Hegazy, Maha Abdel Monem
Badawey, Amr
Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets
title Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets
title_full Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets
title_fullStr Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets
title_full_unstemmed Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets
title_short Analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in Comtrex tablets
title_sort analytical methods for the determination of paracetamol, pseudoephedrine and brompheniramine in comtrex tablets
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6661757/
https://www.ncbi.nlm.nih.gov/pubmed/31384825
http://dx.doi.org/10.1186/s13065-019-0595-6
work_keys_str_mv AT youssefsouhahosam analyticalmethodsforthedeterminationofparacetamolpseudoephedrineandbrompheniramineincomtrextablets
AT mohameddalia analyticalmethodsforthedeterminationofparacetamolpseudoephedrineandbrompheniramineincomtrextablets
AT hegazymahaabdelmonem analyticalmethodsforthedeterminationofparacetamolpseudoephedrineandbrompheniramineincomtrextablets
AT badaweyamr analyticalmethodsforthedeterminationofparacetamolpseudoephedrineandbrompheniramineincomtrextablets