Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study

The study investigated touch and pain sensations and the correlation between them in diadynamic current (DD) and transcutaneous electrical nerve stimulation (TENS), electrotherapies commonly applied in musculoskeletal disorders and occupational rehabilitation medicine. Forty healthy subjects were tr...

Descripción completa

Detalles Bibliográficos
Autores principales: Demidaś, Aneta, Zarzycki, Mikołaj
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6662437/
https://www.ncbi.nlm.nih.gov/pubmed/31380442
http://dx.doi.org/10.1155/2019/9073073
_version_ 1783439651872178176
author Demidaś, Aneta
Zarzycki, Mikołaj
author_facet Demidaś, Aneta
Zarzycki, Mikołaj
author_sort Demidaś, Aneta
collection PubMed
description The study investigated touch and pain sensations and the correlation between them in diadynamic current (DD) and transcutaneous electrical nerve stimulation (TENS), electrotherapies commonly applied in musculoskeletal disorders and occupational rehabilitation medicine. Forty healthy subjects were treated with either DD (n=20) or TENS (n=20). Each treatment consisted of three sessions with one-week interval. Touch sensation was determined with the JVP Domes esthesiometer, pain sensation with pressure pain threshold (PPT), and pressure pain tolerance threshold (PPTO) by an algometer. During each session the measurements were performed before the application of the procedure (T0), immediately after it (T1), and 30 minutes after the end of the procedure (T2). Both DD and TENS increased touch sensation (p<0.01) and did not significantly alter PPT and PPTO (p>0.05). No statistically significant differences in short-term effects, i.e., 3 weeks of the trial, were noted between DD and TENS in their influence on touch and pain sensations (p>0.05). There was a high significant correlation between touch and pain sensations in DD (r=0.86). TENS and DD caused similar analgesic effects. DD, which is shorter in the duration of the treatment, may comprise a realistic alternative to TENS in clinical practice of pain management.
format Online
Article
Text
id pubmed-6662437
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-66624372019-08-04 Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study Demidaś, Aneta Zarzycki, Mikołaj Biomed Res Int Clinical Study The study investigated touch and pain sensations and the correlation between them in diadynamic current (DD) and transcutaneous electrical nerve stimulation (TENS), electrotherapies commonly applied in musculoskeletal disorders and occupational rehabilitation medicine. Forty healthy subjects were treated with either DD (n=20) or TENS (n=20). Each treatment consisted of three sessions with one-week interval. Touch sensation was determined with the JVP Domes esthesiometer, pain sensation with pressure pain threshold (PPT), and pressure pain tolerance threshold (PPTO) by an algometer. During each session the measurements were performed before the application of the procedure (T0), immediately after it (T1), and 30 minutes after the end of the procedure (T2). Both DD and TENS increased touch sensation (p<0.01) and did not significantly alter PPT and PPTO (p>0.05). No statistically significant differences in short-term effects, i.e., 3 weeks of the trial, were noted between DD and TENS in their influence on touch and pain sensations (p>0.05). There was a high significant correlation between touch and pain sensations in DD (r=0.86). TENS and DD caused similar analgesic effects. DD, which is shorter in the duration of the treatment, may comprise a realistic alternative to TENS in clinical practice of pain management. Hindawi 2019-07-17 /pmc/articles/PMC6662437/ /pubmed/31380442 http://dx.doi.org/10.1155/2019/9073073 Text en Copyright © 2019 Aneta Demidaś and Mikołaj Zarzycki. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Demidaś, Aneta
Zarzycki, Mikołaj
Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study
title Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study
title_full Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study
title_fullStr Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study
title_full_unstemmed Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study
title_short Touch and Pain Sensations in Diadynamic Current (DD) and Transcutaneous Electrical Nerve Stimulation (TENS): A Randomized Study
title_sort touch and pain sensations in diadynamic current (dd) and transcutaneous electrical nerve stimulation (tens): a randomized study
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6662437/
https://www.ncbi.nlm.nih.gov/pubmed/31380442
http://dx.doi.org/10.1155/2019/9073073
work_keys_str_mv AT demidasaneta touchandpainsensationsindiadynamiccurrentddandtranscutaneouselectricalnervestimulationtensarandomizedstudy
AT zarzyckimikołaj touchandpainsensationsindiadynamiccurrentddandtranscutaneouselectricalnervestimulationtensarandomizedstudy