Implementation of cylindrical PET scanners with block detector geometry in STIR
BACKGROUND: Software for Tomographic Image Reconstruction (STIR) is an open-source library for PET and SPECT image reconstruction, implementing iterative reconstruction as well as 2D- and 3D-filtered back projection. Quantitative reconstruction of PET data requires the knowledge of the scanner geome...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6663957/ https://www.ncbi.nlm.nih.gov/pubmed/31359303 http://dx.doi.org/10.1186/s40658-019-0248-9 |
_version_ | 1783439804884582400 |
---|---|
author | Khateri, Parisa Fischer, Jannis Lustermann, Werner Tsoumpas, Charalampos Dissertori, Günther |
author_facet | Khateri, Parisa Fischer, Jannis Lustermann, Werner Tsoumpas, Charalampos Dissertori, Günther |
author_sort | Khateri, Parisa |
collection | PubMed |
description | BACKGROUND: Software for Tomographic Image Reconstruction (STIR) is an open-source library for PET and SPECT image reconstruction, implementing iterative reconstruction as well as 2D- and 3D-filtered back projection. Quantitative reconstruction of PET data requires the knowledge of the scanner geometry. Typical scanners, clinical as well as pre-clinical ones, use a block-type geometry. Several rectangular blocks of crystals are arranged into regular polygons. Multiple of such polygons are arranged along the scanner axis. However, the geometrical representation of a scanner provided by STIR is a cylinder made of rings of individual crystals equally distributed in axial and transaxial directions. The data of realistic scanners are projected onto such virtual scanners prior to image reconstruction. This results in reduced quality of the reconstructed image. In this study, we implemented the above-described block geometry into the STIR library, permitting the image reconstruction without the interpolation step. In order to evaluate the difference in image quality, we performed Monte Carlo simulation studies of three different scanner designs: two scanners with multiple crystals per block and one with a single crystal per block. Simulated data were reconstructed using the standard STIR method and the newly implemented block geometry. RESULTS: Visual comparison between the images reconstructed by the two models for the block-type scanners shows that the new implementation enhances the image quality to the extent that the results before normalization correction are comparable with those after normalization correction. The simulation result of a uniform cylinder shows that the coefficient of variation decreases from 25.8% to 20.9% by using the new implementation in STIR. Spatial resolution is enhanced resulting in a lower partial loss of intensity in sources of small size, e.g., the spill-over ratio for spherical sources of 1.8 mm diameter is 0.19 in the block and 0.34 in the cylindrical model. CONCLUSIONS: Results indicate a significant improvement for the new model in comparison with the old one which mapped the polygonal geometry into a cylinder. The new implementation was tested and is available for use via the library of Swiss Federal Institute of Technology in Zurich (ETH). |
format | Online Article Text |
id | pubmed-6663957 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-66639572019-08-12 Implementation of cylindrical PET scanners with block detector geometry in STIR Khateri, Parisa Fischer, Jannis Lustermann, Werner Tsoumpas, Charalampos Dissertori, Günther EJNMMI Phys Original Research BACKGROUND: Software for Tomographic Image Reconstruction (STIR) is an open-source library for PET and SPECT image reconstruction, implementing iterative reconstruction as well as 2D- and 3D-filtered back projection. Quantitative reconstruction of PET data requires the knowledge of the scanner geometry. Typical scanners, clinical as well as pre-clinical ones, use a block-type geometry. Several rectangular blocks of crystals are arranged into regular polygons. Multiple of such polygons are arranged along the scanner axis. However, the geometrical representation of a scanner provided by STIR is a cylinder made of rings of individual crystals equally distributed in axial and transaxial directions. The data of realistic scanners are projected onto such virtual scanners prior to image reconstruction. This results in reduced quality of the reconstructed image. In this study, we implemented the above-described block geometry into the STIR library, permitting the image reconstruction without the interpolation step. In order to evaluate the difference in image quality, we performed Monte Carlo simulation studies of three different scanner designs: two scanners with multiple crystals per block and one with a single crystal per block. Simulated data were reconstructed using the standard STIR method and the newly implemented block geometry. RESULTS: Visual comparison between the images reconstructed by the two models for the block-type scanners shows that the new implementation enhances the image quality to the extent that the results before normalization correction are comparable with those after normalization correction. The simulation result of a uniform cylinder shows that the coefficient of variation decreases from 25.8% to 20.9% by using the new implementation in STIR. Spatial resolution is enhanced resulting in a lower partial loss of intensity in sources of small size, e.g., the spill-over ratio for spherical sources of 1.8 mm diameter is 0.19 in the block and 0.34 in the cylindrical model. CONCLUSIONS: Results indicate a significant improvement for the new model in comparison with the old one which mapped the polygonal geometry into a cylinder. The new implementation was tested and is available for use via the library of Swiss Federal Institute of Technology in Zurich (ETH). Springer International Publishing 2019-07-29 /pmc/articles/PMC6663957/ /pubmed/31359303 http://dx.doi.org/10.1186/s40658-019-0248-9 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Khateri, Parisa Fischer, Jannis Lustermann, Werner Tsoumpas, Charalampos Dissertori, Günther Implementation of cylindrical PET scanners with block detector geometry in STIR |
title | Implementation of cylindrical PET scanners with block detector geometry in STIR |
title_full | Implementation of cylindrical PET scanners with block detector geometry in STIR |
title_fullStr | Implementation of cylindrical PET scanners with block detector geometry in STIR |
title_full_unstemmed | Implementation of cylindrical PET scanners with block detector geometry in STIR |
title_short | Implementation of cylindrical PET scanners with block detector geometry in STIR |
title_sort | implementation of cylindrical pet scanners with block detector geometry in stir |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6663957/ https://www.ncbi.nlm.nih.gov/pubmed/31359303 http://dx.doi.org/10.1186/s40658-019-0248-9 |
work_keys_str_mv | AT khateriparisa implementationofcylindricalpetscannerswithblockdetectorgeometryinstir AT fischerjannis implementationofcylindricalpetscannerswithblockdetectorgeometryinstir AT lustermannwerner implementationofcylindricalpetscannerswithblockdetectorgeometryinstir AT tsoumpascharalampos implementationofcylindricalpetscannerswithblockdetectorgeometryinstir AT dissertorigunther implementationofcylindricalpetscannerswithblockdetectorgeometryinstir |