Cargando…
Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies
Cardiovascular diseases are the first cause of death globally. Their early diagnosis requires ultrasensitive tools enabling the detection of minor structural and functional alterations in small arteries. Such analyses have been traditionally performed with video imaging-based myographs, which helped...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664303/ https://www.ncbi.nlm.nih.gov/pubmed/31396105 http://dx.doi.org/10.3389/fphys.2019.00940 |
_version_ | 1783439870713135104 |
---|---|
author | Rodríguez-Rodríguez, Rosalía Ackermann, Tobias Nils Plaza, Jose Antonio Simonsen, Ulf Matchkov, Vladimir Llobera, Andreu Munoz-Berbel, Xavier |
author_facet | Rodríguez-Rodríguez, Rosalía Ackermann, Tobias Nils Plaza, Jose Antonio Simonsen, Ulf Matchkov, Vladimir Llobera, Andreu Munoz-Berbel, Xavier |
author_sort | Rodríguez-Rodríguez, Rosalía |
collection | PubMed |
description | Cardiovascular diseases are the first cause of death globally. Their early diagnosis requires ultrasensitive tools enabling the detection of minor structural and functional alterations in small arteries. Such analyses have been traditionally performed with video imaging-based myographs, which helped to investigate the pathophysiology of the microvessels. Since new vascular questions have emerged, substantial modifications are necessary to improve the performance of imaging and tracking software, reducing the cost and minimizing the microvessel cleaning and manipulation. To address these limitations, we present a photonic microsystem fabricated in polydimethylsiloxane and integrating micro-optical elements and a lightguide-cantilever for sub-micrometric analysis of small arteries (between 125 and 400 μm of basal diameter). This technology enables simultaneous measurement of arterial distension, stiffness, vasomotion, and heartbeat and without the need for advanced imaging system. The microsystem has a limit of detection of 2 μm, five times lower than video imaging-based myographs, is two times more sensitive than them (0.5 μm/mmHg), reduces variability to half and doubles the linear range reported in these myographs. More importantly, it allows the analysis of intact arteries preserving the integrity and function of surrounding tissues. Assays can be conducted in three configurations according to the surrounding tissue: (i) isolated arteries (in vitro) where the surrounding tissue is partially removed, (ii) non-isolated arteries (in vivo) with surrounding tissue partially removed, and (iii) intact arteries in vivo preserving surrounding tissue as well as function and integrity. This technology represents a step forward in the prediction of cardiovascular risk. |
format | Online Article Text |
id | pubmed-6664303 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-66643032019-08-08 Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies Rodríguez-Rodríguez, Rosalía Ackermann, Tobias Nils Plaza, Jose Antonio Simonsen, Ulf Matchkov, Vladimir Llobera, Andreu Munoz-Berbel, Xavier Front Physiol Physiology Cardiovascular diseases are the first cause of death globally. Their early diagnosis requires ultrasensitive tools enabling the detection of minor structural and functional alterations in small arteries. Such analyses have been traditionally performed with video imaging-based myographs, which helped to investigate the pathophysiology of the microvessels. Since new vascular questions have emerged, substantial modifications are necessary to improve the performance of imaging and tracking software, reducing the cost and minimizing the microvessel cleaning and manipulation. To address these limitations, we present a photonic microsystem fabricated in polydimethylsiloxane and integrating micro-optical elements and a lightguide-cantilever for sub-micrometric analysis of small arteries (between 125 and 400 μm of basal diameter). This technology enables simultaneous measurement of arterial distension, stiffness, vasomotion, and heartbeat and without the need for advanced imaging system. The microsystem has a limit of detection of 2 μm, five times lower than video imaging-based myographs, is two times more sensitive than them (0.5 μm/mmHg), reduces variability to half and doubles the linear range reported in these myographs. More importantly, it allows the analysis of intact arteries preserving the integrity and function of surrounding tissues. Assays can be conducted in three configurations according to the surrounding tissue: (i) isolated arteries (in vitro) where the surrounding tissue is partially removed, (ii) non-isolated arteries (in vivo) with surrounding tissue partially removed, and (iii) intact arteries in vivo preserving surrounding tissue as well as function and integrity. This technology represents a step forward in the prediction of cardiovascular risk. Frontiers Media S.A. 2019-07-23 /pmc/articles/PMC6664303/ /pubmed/31396105 http://dx.doi.org/10.3389/fphys.2019.00940 Text en Copyright © 2019 Rodríguez-Rodríguez, Ackermann, Plaza, Simonsen, Matchkov, Llobera and Munoz-Berbel. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Rodríguez-Rodríguez, Rosalía Ackermann, Tobias Nils Plaza, Jose Antonio Simonsen, Ulf Matchkov, Vladimir Llobera, Andreu Munoz-Berbel, Xavier Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies |
title | Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies |
title_full | Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies |
title_fullStr | Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies |
title_full_unstemmed | Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies |
title_short | Ultrasensitive Photonic Microsystem Enabling Sub-micrometric Monitoring of Arterial Oscillations for Advanced Cardiovascular Studies |
title_sort | ultrasensitive photonic microsystem enabling sub-micrometric monitoring of arterial oscillations for advanced cardiovascular studies |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664303/ https://www.ncbi.nlm.nih.gov/pubmed/31396105 http://dx.doi.org/10.3389/fphys.2019.00940 |
work_keys_str_mv | AT rodriguezrodriguezrosalia ultrasensitivephotonicmicrosystemenablingsubmicrometricmonitoringofarterialoscillationsforadvancedcardiovascularstudies AT ackermanntobiasnils ultrasensitivephotonicmicrosystemenablingsubmicrometricmonitoringofarterialoscillationsforadvancedcardiovascularstudies AT plazajoseantonio ultrasensitivephotonicmicrosystemenablingsubmicrometricmonitoringofarterialoscillationsforadvancedcardiovascularstudies AT simonsenulf ultrasensitivephotonicmicrosystemenablingsubmicrometricmonitoringofarterialoscillationsforadvancedcardiovascularstudies AT matchkovvladimir ultrasensitivephotonicmicrosystemenablingsubmicrometricmonitoringofarterialoscillationsforadvancedcardiovascularstudies AT lloberaandreu ultrasensitivephotonicmicrosystemenablingsubmicrometricmonitoringofarterialoscillationsforadvancedcardiovascularstudies AT munozberbelxavier ultrasensitivephotonicmicrosystemenablingsubmicrometricmonitoringofarterialoscillationsforadvancedcardiovascularstudies |