Cargando…
Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy
BACKGROUND: The position of the intraocular lens (IOL) is a major factor that affects the final visual acuity after cataract surgery. However, no prospective study has compared the IOL positions associated with the sutureless intrascleral technique and the standard transscleral suturing technique. T...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664768/ https://www.ncbi.nlm.nih.gov/pubmed/31384481 http://dx.doi.org/10.1186/s40942-019-0182-y |
_version_ | 1783439954347556864 |
---|---|
author | Marianelli, Bruna Ferraço Mendes, Thaís Sousa de Almeida Manzano, Roberta Pereira Garcia, Patrícia Novita Teixeira, Ivan Corso |
author_facet | Marianelli, Bruna Ferraço Mendes, Thaís Sousa de Almeida Manzano, Roberta Pereira Garcia, Patrícia Novita Teixeira, Ivan Corso |
author_sort | Marianelli, Bruna Ferraço |
collection | PubMed |
description | BACKGROUND: The position of the intraocular lens (IOL) is a major factor that affects the final visual acuity after cataract surgery. However, no prospective study has compared the IOL positions associated with the sutureless intrascleral technique and the standard transscleral suturing technique. The current study compared the IOL positions in the two techniques using ultrasound biomicroscopy (UBM) in vivo. METHODS: Twenty-one eyes of 21 patients were included in this observational study conducted between February and May 2015. Eleven patients underwent the sutureless intrascleral technique, and 10 patients underwent transscleral fixation with suturing. Ophthalmologic examination and UBM were performed in all patients. Optic tilt was measured in relation to the iris plane. The haptic location was defined. Mann–Whitney test and multiple linear regression were used to analyze the vertical and horizontal gradients. Significant differences were considered when p ≤ 0.05. RESULTS: The most common indication for scleral fixation was a complication during phacoemulsification (81.81% in the sutureless group and 60% in the suture group). The mean vertical and horizontal tilts were, respectively, 0.24 ± 0.21 and 0.25 ± 0.19 mm in the sutureless group and 0.14 ± 0.17 and 0.23 ± 0.16 mm in the suture group. No significant differences were seen in the vertical tilt and horizontal tilt (p = 0.888 and p = 0.148, respectively) between the groups. Gender (p = 0.835), age (p = 0.888), follow-up time (p = 0.915), and surgical duration (p = 0.094) were not associated with optic tilt. Of the 22 haptics in the sutureless group, 21 (95.45%) were in the intrascleral tunnel; of the 20 haptics in the suture group, 13 (65%) were posterior to the ciliary body, four (20%) anterior to the ciliary body, and three (15%) in the ciliary sulcus. CONCLUSION: This study showed that there are no significant differences in the IOL positions between the two techniques. |
format | Online Article Text |
id | pubmed-6664768 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-66647682019-08-05 Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy Marianelli, Bruna Ferraço Mendes, Thaís Sousa de Almeida Manzano, Roberta Pereira Garcia, Patrícia Novita Teixeira, Ivan Corso Int J Retina Vitreous Original Article BACKGROUND: The position of the intraocular lens (IOL) is a major factor that affects the final visual acuity after cataract surgery. However, no prospective study has compared the IOL positions associated with the sutureless intrascleral technique and the standard transscleral suturing technique. The current study compared the IOL positions in the two techniques using ultrasound biomicroscopy (UBM) in vivo. METHODS: Twenty-one eyes of 21 patients were included in this observational study conducted between February and May 2015. Eleven patients underwent the sutureless intrascleral technique, and 10 patients underwent transscleral fixation with suturing. Ophthalmologic examination and UBM were performed in all patients. Optic tilt was measured in relation to the iris plane. The haptic location was defined. Mann–Whitney test and multiple linear regression were used to analyze the vertical and horizontal gradients. Significant differences were considered when p ≤ 0.05. RESULTS: The most common indication for scleral fixation was a complication during phacoemulsification (81.81% in the sutureless group and 60% in the suture group). The mean vertical and horizontal tilts were, respectively, 0.24 ± 0.21 and 0.25 ± 0.19 mm in the sutureless group and 0.14 ± 0.17 and 0.23 ± 0.16 mm in the suture group. No significant differences were seen in the vertical tilt and horizontal tilt (p = 0.888 and p = 0.148, respectively) between the groups. Gender (p = 0.835), age (p = 0.888), follow-up time (p = 0.915), and surgical duration (p = 0.094) were not associated with optic tilt. Of the 22 haptics in the sutureless group, 21 (95.45%) were in the intrascleral tunnel; of the 20 haptics in the suture group, 13 (65%) were posterior to the ciliary body, four (20%) anterior to the ciliary body, and three (15%) in the ciliary sulcus. CONCLUSION: This study showed that there are no significant differences in the IOL positions between the two techniques. BioMed Central 2019-07-29 /pmc/articles/PMC6664768/ /pubmed/31384481 http://dx.doi.org/10.1186/s40942-019-0182-y Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Original Article Marianelli, Bruna Ferraço Mendes, Thaís Sousa de Almeida Manzano, Roberta Pereira Garcia, Patrícia Novita Teixeira, Ivan Corso Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy |
title | Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy |
title_full | Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy |
title_fullStr | Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy |
title_full_unstemmed | Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy |
title_short | Observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy |
title_sort | observational study of intraocular lens tilt in sutureless intrascleral fixation versus standard transscleral suture fixation determined by ultrasound biomicroscopy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664768/ https://www.ncbi.nlm.nih.gov/pubmed/31384481 http://dx.doi.org/10.1186/s40942-019-0182-y |
work_keys_str_mv | AT marianellibrunaferraco observationalstudyofintraocularlenstiltinsuturelessintrascleralfixationversusstandardtransscleralsuturefixationdeterminedbyultrasoundbiomicroscopy AT mendesthaissousa observationalstudyofintraocularlenstiltinsuturelessintrascleralfixationversusstandardtransscleralsuturefixationdeterminedbyultrasoundbiomicroscopy AT dealmeidamanzanorobertapereira observationalstudyofintraocularlenstiltinsuturelessintrascleralfixationversusstandardtransscleralsuturefixationdeterminedbyultrasoundbiomicroscopy AT garciapatricianovita observationalstudyofintraocularlenstiltinsuturelessintrascleralfixationversusstandardtransscleralsuturefixationdeterminedbyultrasoundbiomicroscopy AT teixeiraivancorso observationalstudyofintraocularlenstiltinsuturelessintrascleralfixationversusstandardtransscleralsuturefixationdeterminedbyultrasoundbiomicroscopy |