Cargando…

Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness

BACKGROUND: Bedside functional hemodynamic assessment has gained in popularity in the last years to overcome the limitations of static or dynamic indexes in predicting fluid responsiveness. The aim of this systematic review and metanalysis of studies is to investigate the reliability of the function...

Descripción completa

Detalles Bibliográficos
Autores principales: Messina, Antonio, Dell’Anna, Antonio, Baggiani, Marta, Torrini, Flavia, Maresca, Gian Marco, Bennett, Victoria, Saderi, Laura, Sotgiu, Giovanni, Antonelli, Massimo, Cecconi, Maurizio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664788/
https://www.ncbi.nlm.nih.gov/pubmed/31358025
http://dx.doi.org/10.1186/s13054-019-2545-z
_version_ 1783439959096557568
author Messina, Antonio
Dell’Anna, Antonio
Baggiani, Marta
Torrini, Flavia
Maresca, Gian Marco
Bennett, Victoria
Saderi, Laura
Sotgiu, Giovanni
Antonelli, Massimo
Cecconi, Maurizio
author_facet Messina, Antonio
Dell’Anna, Antonio
Baggiani, Marta
Torrini, Flavia
Maresca, Gian Marco
Bennett, Victoria
Saderi, Laura
Sotgiu, Giovanni
Antonelli, Massimo
Cecconi, Maurizio
author_sort Messina, Antonio
collection PubMed
description BACKGROUND: Bedside functional hemodynamic assessment has gained in popularity in the last years to overcome the limitations of static or dynamic indexes in predicting fluid responsiveness. The aim of this systematic review and metanalysis of studies is to investigate the reliability of the functional hemodynamic tests (FHTs) used to assess fluid responsiveness in adult patients in the intensive care unit (ICU) and operating room (OR). METHODS: MEDLINE, EMBASE, and Cochrane databases were screened for relevant articles using a FHT, with the exception of the passive leg raising. The QUADAS-2 scale was used to assess the risk of bias of the included studies. In-between study heterogeneity was assessed through the I(2) indicator. Bias assessment graphs were plotted, and Egger’s regression analysis was used to evaluate the publication bias. The metanalysis determined the pooled area under the receiving operating characteristic (ROC) curve, sensitivity, specificity, and threshold for two FHTs: the end-expiratory occlusion test (EEOT) and the mini-fluid challenge (FC). RESULTS: After text selection, 21 studies met the inclusion criteria, 7 performed in the OR, and 14 in the ICU between 2005 and 2018. The search included 805 patients and 870 FCs with a median (IQR) of 39 (25–50) patients and 41 (30–52) FCs per study. The median fluid responsiveness was 54% (45–59). Ten studies (47.6%) adopted a gray zone analysis of the ROC curve, and a median (IQR) of 20% (15–51) of the enrolled patients was included in the gray zone. The pooled area under the ROC curve for the end-expiratory occlusion test (EEOT) was 0.96 (95%CI 0.92–1.00). The pooled sensitivity and specificity were 0.86 (95%CI 0.74–0.94) and 0.91 (95%CI 0.85–0.95), respectively, with a best threshold of 5% (4.0–8.0%). The pooled area under the ROC curve for the mini-FC was 0.91 (95%CI 0.85–0.97). The pooled sensitivity and specificity were 0.82 (95%CI 0.76–0.88) and 0.83 (95%CI 0.77–0.89), respectively, with a best threshold of 5% (3.0–7.0%). CONCLUSIONS: The EEOT and the mini-FC reliably predict fluid responsiveness in the ICU and OR. Other FHTs have been tested insofar in heterogeneous clinical settings and, despite promising results, warrant further investigations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13054-019-2545-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6664788
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66647882019-08-05 Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness Messina, Antonio Dell’Anna, Antonio Baggiani, Marta Torrini, Flavia Maresca, Gian Marco Bennett, Victoria Saderi, Laura Sotgiu, Giovanni Antonelli, Massimo Cecconi, Maurizio Crit Care Research BACKGROUND: Bedside functional hemodynamic assessment has gained in popularity in the last years to overcome the limitations of static or dynamic indexes in predicting fluid responsiveness. The aim of this systematic review and metanalysis of studies is to investigate the reliability of the functional hemodynamic tests (FHTs) used to assess fluid responsiveness in adult patients in the intensive care unit (ICU) and operating room (OR). METHODS: MEDLINE, EMBASE, and Cochrane databases were screened for relevant articles using a FHT, with the exception of the passive leg raising. The QUADAS-2 scale was used to assess the risk of bias of the included studies. In-between study heterogeneity was assessed through the I(2) indicator. Bias assessment graphs were plotted, and Egger’s regression analysis was used to evaluate the publication bias. The metanalysis determined the pooled area under the receiving operating characteristic (ROC) curve, sensitivity, specificity, and threshold for two FHTs: the end-expiratory occlusion test (EEOT) and the mini-fluid challenge (FC). RESULTS: After text selection, 21 studies met the inclusion criteria, 7 performed in the OR, and 14 in the ICU between 2005 and 2018. The search included 805 patients and 870 FCs with a median (IQR) of 39 (25–50) patients and 41 (30–52) FCs per study. The median fluid responsiveness was 54% (45–59). Ten studies (47.6%) adopted a gray zone analysis of the ROC curve, and a median (IQR) of 20% (15–51) of the enrolled patients was included in the gray zone. The pooled area under the ROC curve for the end-expiratory occlusion test (EEOT) was 0.96 (95%CI 0.92–1.00). The pooled sensitivity and specificity were 0.86 (95%CI 0.74–0.94) and 0.91 (95%CI 0.85–0.95), respectively, with a best threshold of 5% (4.0–8.0%). The pooled area under the ROC curve for the mini-FC was 0.91 (95%CI 0.85–0.97). The pooled sensitivity and specificity were 0.82 (95%CI 0.76–0.88) and 0.83 (95%CI 0.77–0.89), respectively, with a best threshold of 5% (3.0–7.0%). CONCLUSIONS: The EEOT and the mini-FC reliably predict fluid responsiveness in the ICU and OR. Other FHTs have been tested insofar in heterogeneous clinical settings and, despite promising results, warrant further investigations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13054-019-2545-z) contains supplementary material, which is available to authorized users. BioMed Central 2019-07-29 /pmc/articles/PMC6664788/ /pubmed/31358025 http://dx.doi.org/10.1186/s13054-019-2545-z Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Messina, Antonio
Dell’Anna, Antonio
Baggiani, Marta
Torrini, Flavia
Maresca, Gian Marco
Bennett, Victoria
Saderi, Laura
Sotgiu, Giovanni
Antonelli, Massimo
Cecconi, Maurizio
Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness
title Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness
title_full Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness
title_fullStr Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness
title_full_unstemmed Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness
title_short Functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness
title_sort functional hemodynamic tests: a systematic review and a metanalysis on the reliability of the end-expiratory occlusion test and of the mini-fluid challenge in predicting fluid responsiveness
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6664788/
https://www.ncbi.nlm.nih.gov/pubmed/31358025
http://dx.doi.org/10.1186/s13054-019-2545-z
work_keys_str_mv AT messinaantonio functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT dellannaantonio functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT baggianimarta functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT torriniflavia functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT marescagianmarco functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT bennettvictoria functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT saderilaura functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT sotgiugiovanni functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT antonellimassimo functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness
AT cecconimaurizio functionalhemodynamictestsasystematicreviewandametanalysisonthereliabilityoftheendexpiratoryocclusiontestandoftheminifluidchallengeinpredictingfluidresponsiveness