Cargando…

Is a pillow a risk factor for glaucoma?

PURPOSE: To study whether a clinically significant increase in intraocular pressure (IOP) occurs during simulated sleep conditions with the subject's head turned comfortably into a pillow (the simulated sleep position) and the effect of protective glasses on any such IOP rise. METHODS: A specia...

Descripción completa

Detalles Bibliográficos
Autores principales: van Meurs, Ida A., Thepass, Gijs, Stuij, Arthur A., Bollemeijer, Jan Geert, Lemij, Hans G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6667898/
https://www.ncbi.nlm.nih.gov/pubmed/30298695
http://dx.doi.org/10.1111/aos.13881
_version_ 1783440120484986880
author van Meurs, Ida A.
Thepass, Gijs
Stuij, Arthur A.
Bollemeijer, Jan Geert
Lemij, Hans G.
author_facet van Meurs, Ida A.
Thepass, Gijs
Stuij, Arthur A.
Bollemeijer, Jan Geert
Lemij, Hans G.
author_sort van Meurs, Ida A.
collection PubMed
description PURPOSE: To study whether a clinically significant increase in intraocular pressure (IOP) occurs during simulated sleep conditions with the subject's head turned comfortably into a pillow (the simulated sleep position) and the effect of protective glasses on any such IOP rise. METHODS: A specially developed electronic epipalpebral pressure (EPP) sensor was attached to an eyelid of the right eye of all participants: 11 patients with primary open‐angle glaucoma and 11 healthy volunteers. During calibration, mechanical pressure was applied to the EPP sensor taped to the lower eyelid and the IOP was measured simultaneously at the slit lamp by Goldmann applanation tonometry. The EPP was increased in a stepwise fashion to assess the relationship between EPP and IOP for each individual eye. Thereafter, EPP (with the sensor now taped to the upper eyelid) measurements were performed in the simulated sleep position, both with and without protective glasses. The EPP was determined in each individual eye, and the estimated IOP was then inferred from the established EPP/IOP relationship. RESULTS: In the simulated sleep position, the mean IOP increased by an estimated 19.6 mmHg (SD: 7.5; range 11.6–32.8; p < 0.0001) in the patient group and 28.0 mmHg (SD: 9.6; range 12.3–41.1); p < 0.0001) in the control group. When the subjects wore protective glasses, the mean estimated IOP decreased again by 16.3 mmHg (SD: 5.6; range 9.8–28.1; p < 0.0001) in the patient group and 25.1 mmHg (SD: 8.2; range 11.7–38.3; p = <0.0001) in the control group. CONCLUSION: Turning the head into a pillow gave a large and clinically significant increase in the estimated IOP in the simulated sleep position. With protective glasses, however, the increase in estimated IOP was almost absent. Therefore, protective shielding of the eyes during sleep may be a treatment option in glaucoma.
format Online
Article
Text
id pubmed-6667898
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-66678982019-08-06 Is a pillow a risk factor for glaucoma? van Meurs, Ida A. Thepass, Gijs Stuij, Arthur A. Bollemeijer, Jan Geert Lemij, Hans G. Acta Ophthalmol Original Articles PURPOSE: To study whether a clinically significant increase in intraocular pressure (IOP) occurs during simulated sleep conditions with the subject's head turned comfortably into a pillow (the simulated sleep position) and the effect of protective glasses on any such IOP rise. METHODS: A specially developed electronic epipalpebral pressure (EPP) sensor was attached to an eyelid of the right eye of all participants: 11 patients with primary open‐angle glaucoma and 11 healthy volunteers. During calibration, mechanical pressure was applied to the EPP sensor taped to the lower eyelid and the IOP was measured simultaneously at the slit lamp by Goldmann applanation tonometry. The EPP was increased in a stepwise fashion to assess the relationship between EPP and IOP for each individual eye. Thereafter, EPP (with the sensor now taped to the upper eyelid) measurements were performed in the simulated sleep position, both with and without protective glasses. The EPP was determined in each individual eye, and the estimated IOP was then inferred from the established EPP/IOP relationship. RESULTS: In the simulated sleep position, the mean IOP increased by an estimated 19.6 mmHg (SD: 7.5; range 11.6–32.8; p < 0.0001) in the patient group and 28.0 mmHg (SD: 9.6; range 12.3–41.1); p < 0.0001) in the control group. When the subjects wore protective glasses, the mean estimated IOP decreased again by 16.3 mmHg (SD: 5.6; range 9.8–28.1; p < 0.0001) in the patient group and 25.1 mmHg (SD: 8.2; range 11.7–38.3; p = <0.0001) in the control group. CONCLUSION: Turning the head into a pillow gave a large and clinically significant increase in the estimated IOP in the simulated sleep position. With protective glasses, however, the increase in estimated IOP was almost absent. Therefore, protective shielding of the eyes during sleep may be a treatment option in glaucoma. John Wiley and Sons Inc. 2018-10-08 2018-12 /pmc/articles/PMC6667898/ /pubmed/30298695 http://dx.doi.org/10.1111/aos.13881 Text en © 2018 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
van Meurs, Ida A.
Thepass, Gijs
Stuij, Arthur A.
Bollemeijer, Jan Geert
Lemij, Hans G.
Is a pillow a risk factor for glaucoma?
title Is a pillow a risk factor for glaucoma?
title_full Is a pillow a risk factor for glaucoma?
title_fullStr Is a pillow a risk factor for glaucoma?
title_full_unstemmed Is a pillow a risk factor for glaucoma?
title_short Is a pillow a risk factor for glaucoma?
title_sort is a pillow a risk factor for glaucoma?
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6667898/
https://www.ncbi.nlm.nih.gov/pubmed/30298695
http://dx.doi.org/10.1111/aos.13881
work_keys_str_mv AT vanmeursidaa isapillowariskfactorforglaucoma
AT thepassgijs isapillowariskfactorforglaucoma
AT stuijarthura isapillowariskfactorforglaucoma
AT bollemeijerjangeert isapillowariskfactorforglaucoma
AT lemijhansg isapillowariskfactorforglaucoma