Cargando…
Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules
PURPOSE: Our purpose was to assess the differences in growth rates of multiple pulmonary metastatic nodules using three-dimensional (3D) computed tomography (CT) volumetry and propose a concept of CT spatial tumor heterogeneity. MATERIALS AND METHODS: We manually measured the largest diameter of met...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6675092/ https://www.ncbi.nlm.nih.gov/pubmed/31369602 http://dx.doi.org/10.1371/journal.pone.0220550 |
_version_ | 1783440615029080064 |
---|---|
author | Yoo, Jeongin Chong, Semin Lim, Changwon Heo, Miyoung Hwang, In Gyu |
author_facet | Yoo, Jeongin Chong, Semin Lim, Changwon Heo, Miyoung Hwang, In Gyu |
author_sort | Yoo, Jeongin |
collection | PubMed |
description | PURPOSE: Our purpose was to assess the differences in growth rates of multiple pulmonary metastatic nodules using three-dimensional (3D) computed tomography (CT) volumetry and propose a concept of CT spatial tumor heterogeneity. MATERIALS AND METHODS: We manually measured the largest diameter of metastatic pulmonary nodules on chest CT scans, and calculated the 3D maximum diameter and the volume using a semi-automated 3D CT volumetry of each nodule. The tumor response was assessed according to the revised RECIST 1.1. We defined a nodule as an outlier based on 1.5 times growth during follow-up. The CT spatial tumor heterogeneity was statistically analyzed by the “minimum combination t-test method” devised in our study. RESULTS: On manual measurement, the tumor response category was stable disease (SD) in all 10 patients. Of them, total 155 metastatic nodules (4–52 nodules per patient) were segmented using the 3D CT volumetry. In the 3D maximum diameter, 9 patients had SD except for one patient with partial response in the two selected nodules; for the volume, all 10 patients were SD. For the 3D maximum diameter, six patients had at least one outlier; whereas five patients had the outlier on the volume measurement. Six patients were proven to have overall CT spatial tumor heterogeneity. CONCLUSIONS: The spatial tumor heterogeneity determined in a CT parametric approach could be statistically assessed. In patients with CT spatial heterogeneity, tumors with different growth rates may be neglected when the nodules are assessed according to the current guideline. |
format | Online Article Text |
id | pubmed-6675092 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-66750922019-08-06 Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules Yoo, Jeongin Chong, Semin Lim, Changwon Heo, Miyoung Hwang, In Gyu PLoS One Research Article PURPOSE: Our purpose was to assess the differences in growth rates of multiple pulmonary metastatic nodules using three-dimensional (3D) computed tomography (CT) volumetry and propose a concept of CT spatial tumor heterogeneity. MATERIALS AND METHODS: We manually measured the largest diameter of metastatic pulmonary nodules on chest CT scans, and calculated the 3D maximum diameter and the volume using a semi-automated 3D CT volumetry of each nodule. The tumor response was assessed according to the revised RECIST 1.1. We defined a nodule as an outlier based on 1.5 times growth during follow-up. The CT spatial tumor heterogeneity was statistically analyzed by the “minimum combination t-test method” devised in our study. RESULTS: On manual measurement, the tumor response category was stable disease (SD) in all 10 patients. Of them, total 155 metastatic nodules (4–52 nodules per patient) were segmented using the 3D CT volumetry. In the 3D maximum diameter, 9 patients had SD except for one patient with partial response in the two selected nodules; for the volume, all 10 patients were SD. For the 3D maximum diameter, six patients had at least one outlier; whereas five patients had the outlier on the volume measurement. Six patients were proven to have overall CT spatial tumor heterogeneity. CONCLUSIONS: The spatial tumor heterogeneity determined in a CT parametric approach could be statistically assessed. In patients with CT spatial heterogeneity, tumors with different growth rates may be neglected when the nodules are assessed according to the current guideline. Public Library of Science 2019-08-01 /pmc/articles/PMC6675092/ /pubmed/31369602 http://dx.doi.org/10.1371/journal.pone.0220550 Text en © 2019 Yoo et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Yoo, Jeongin Chong, Semin Lim, Changwon Heo, Miyoung Hwang, In Gyu Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules |
title | Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules |
title_full | Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules |
title_fullStr | Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules |
title_full_unstemmed | Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules |
title_short | Assessment of spatial tumor heterogeneity using CT growth patterns estimated by tumor tracking on 3D CT volumetry of multiple pulmonary metastatic nodules |
title_sort | assessment of spatial tumor heterogeneity using ct growth patterns estimated by tumor tracking on 3d ct volumetry of multiple pulmonary metastatic nodules |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6675092/ https://www.ncbi.nlm.nih.gov/pubmed/31369602 http://dx.doi.org/10.1371/journal.pone.0220550 |
work_keys_str_mv | AT yoojeongin assessmentofspatialtumorheterogeneityusingctgrowthpatternsestimatedbytumortrackingon3dctvolumetryofmultiplepulmonarymetastaticnodules AT chongsemin assessmentofspatialtumorheterogeneityusingctgrowthpatternsestimatedbytumortrackingon3dctvolumetryofmultiplepulmonarymetastaticnodules AT limchangwon assessmentofspatialtumorheterogeneityusingctgrowthpatternsestimatedbytumortrackingon3dctvolumetryofmultiplepulmonarymetastaticnodules AT heomiyoung assessmentofspatialtumorheterogeneityusingctgrowthpatternsestimatedbytumortrackingon3dctvolumetryofmultiplepulmonarymetastaticnodules AT hwangingyu assessmentofspatialtumorheterogeneityusingctgrowthpatternsestimatedbytumortrackingon3dctvolumetryofmultiplepulmonarymetastaticnodules |