Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics
3D printing technology has allowed the creation of custom applicators for high dose rate (HDR) brachytherapy, especially for complex anatomy. With conformal therapy comes the need for advanced dosimetric verification. It is important to demonstrate how dose to 3D printed materials can be related to...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6676362/ https://www.ncbi.nlm.nih.gov/pubmed/30725341 http://dx.doi.org/10.1186/s41205-019-0040-4 |
_version_ | 1783440751358640128 |
---|---|
author | Oare, Courtney Wilke, Christopher Ehler, Eric Mathew, Damien Sterling, David Ferreira, Clara |
author_facet | Oare, Courtney Wilke, Christopher Ehler, Eric Mathew, Damien Sterling, David Ferreira, Clara |
author_sort | Oare, Courtney |
collection | PubMed |
description | 3D printing technology has allowed the creation of custom applicators for high dose rate (HDR) brachytherapy, especially for complex anatomy. With conformal therapy comes the need for advanced dosimetric verification. It is important to demonstrate how dose to 3D printed materials can be related to dose to water. This study aimed to determine dose differences and uncertainties using 3D printed PLA and ABS plastics for Radiochromic film calibration in HDR brachytherapy. Gafchromic EBT3 film pieces were irradiated in water with an Ir-192 source at calculated dose levels ranging from 0 to 800 cGy, to create the control calibration curve. Similarly, film was placed below 3D printed PLA and ABS blocks and irradiated at the same dose levels calculated for water, ranging from 0 to 800 cGy. After a 72-h development time, film pieces were scanned on a flatbed scanner and the median pixel value was recorded in the region of highest dose. This value was converted to net optical density (NOD). A rational function was used to fit a calibration curve in water that relates NOD to dose for red, green, and blue color channels. Based on this fitted curve, ABS and PLA NOD values were used to estimate dose in 3D printed plastics. From the fitted calibration curve, mean residual error between measured and planned dose to water was less than 1% for each color channel at high dose levels. At high dose levels, ABS and PLA mean residual errors were about 6.9 and 7.8% in the red channel, while 5.2 and 5.7% in the green channel. Combined uncertainties measured to be about 6.9% at high dose levels. This study demonstrated dose differences and uncertainties using 3D printed applicators for HDR Ir-192 brachytherapy. |
format | Online Article Text |
id | pubmed-6676362 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-66763622019-08-02 Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics Oare, Courtney Wilke, Christopher Ehler, Eric Mathew, Damien Sterling, David Ferreira, Clara 3D Print Med Research 3D printing technology has allowed the creation of custom applicators for high dose rate (HDR) brachytherapy, especially for complex anatomy. With conformal therapy comes the need for advanced dosimetric verification. It is important to demonstrate how dose to 3D printed materials can be related to dose to water. This study aimed to determine dose differences and uncertainties using 3D printed PLA and ABS plastics for Radiochromic film calibration in HDR brachytherapy. Gafchromic EBT3 film pieces were irradiated in water with an Ir-192 source at calculated dose levels ranging from 0 to 800 cGy, to create the control calibration curve. Similarly, film was placed below 3D printed PLA and ABS blocks and irradiated at the same dose levels calculated for water, ranging from 0 to 800 cGy. After a 72-h development time, film pieces were scanned on a flatbed scanner and the median pixel value was recorded in the region of highest dose. This value was converted to net optical density (NOD). A rational function was used to fit a calibration curve in water that relates NOD to dose for red, green, and blue color channels. Based on this fitted curve, ABS and PLA NOD values were used to estimate dose in 3D printed plastics. From the fitted calibration curve, mean residual error between measured and planned dose to water was less than 1% for each color channel at high dose levels. At high dose levels, ABS and PLA mean residual errors were about 6.9 and 7.8% in the red channel, while 5.2 and 5.7% in the green channel. Combined uncertainties measured to be about 6.9% at high dose levels. This study demonstrated dose differences and uncertainties using 3D printed applicators for HDR Ir-192 brachytherapy. Springer International Publishing 2019-02-06 /pmc/articles/PMC6676362/ /pubmed/30725341 http://dx.doi.org/10.1186/s41205-019-0040-4 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Oare, Courtney Wilke, Christopher Ehler, Eric Mathew, Damien Sterling, David Ferreira, Clara Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics |
title | Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics |
title_full | Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics |
title_fullStr | Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics |
title_full_unstemmed | Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics |
title_short | Dose calibration of Gafchromic EBT3 film for Ir-192 brachytherapy source using 3D-printed PLA and ABS plastics |
title_sort | dose calibration of gafchromic ebt3 film for ir-192 brachytherapy source using 3d-printed pla and abs plastics |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6676362/ https://www.ncbi.nlm.nih.gov/pubmed/30725341 http://dx.doi.org/10.1186/s41205-019-0040-4 |
work_keys_str_mv | AT oarecourtney dosecalibrationofgafchromicebt3filmforir192brachytherapysourceusing3dprintedplaandabsplastics AT wilkechristopher dosecalibrationofgafchromicebt3filmforir192brachytherapysourceusing3dprintedplaandabsplastics AT ehlereric dosecalibrationofgafchromicebt3filmforir192brachytherapysourceusing3dprintedplaandabsplastics AT mathewdamien dosecalibrationofgafchromicebt3filmforir192brachytherapysourceusing3dprintedplaandabsplastics AT sterlingdavid dosecalibrationofgafchromicebt3filmforir192brachytherapysourceusing3dprintedplaandabsplastics AT ferreiraclara dosecalibrationofgafchromicebt3filmforir192brachytherapysourceusing3dprintedplaandabsplastics |