Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors
The performance of a sensor platform for environmental or industrial monitoring is sensitive to the cost and performance of the individual sensor elements. Thus, the detection limits, accuracy, and precision of commercially available, low-cost carbon dioxide and methane gas concentration sensors wer...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679274/ https://www.ncbi.nlm.nih.gov/pubmed/31323772 http://dx.doi.org/10.3390/s19143157 |
_version_ | 1783441300797784064 |
---|---|
author | Honeycutt, Wesley T. Ley, M. Tyler Materer, Nicholas F. |
author_facet | Honeycutt, Wesley T. Ley, M. Tyler Materer, Nicholas F. |
author_sort | Honeycutt, Wesley T. |
collection | PubMed |
description | The performance of a sensor platform for environmental or industrial monitoring is sensitive to the cost and performance of the individual sensor elements. Thus, the detection limits, accuracy, and precision of commercially available, low-cost carbon dioxide and methane gas concentration sensors were evaluated by precise measurements at known gas concentrations. Sensors were selected based on market availability, cost, power consumption, detection range, and accuracy. A specially constructed gas mixing chamber, coupled to a precision bench-top analyzer, was used to characterize each sensor during a controlled exposure to known gas concentrations. For environmental monitoring, the selected carbon dioxide sensors were characterized around 400 ppm. For methane, the sensor response was first monitored at 0 ppm, close to the typical environmental background. The selected sensors were then evaluated at gas concentrations of several thousand ppm. The determined detection limits accuracy, and precision provides a set of matrices that can be used to evaluate and select sensors for integration into a sensor platform for specific applications. |
format | Online Article Text |
id | pubmed-6679274 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-66792742019-08-19 Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors Honeycutt, Wesley T. Ley, M. Tyler Materer, Nicholas F. Sensors (Basel) Article The performance of a sensor platform for environmental or industrial monitoring is sensitive to the cost and performance of the individual sensor elements. Thus, the detection limits, accuracy, and precision of commercially available, low-cost carbon dioxide and methane gas concentration sensors were evaluated by precise measurements at known gas concentrations. Sensors were selected based on market availability, cost, power consumption, detection range, and accuracy. A specially constructed gas mixing chamber, coupled to a precision bench-top analyzer, was used to characterize each sensor during a controlled exposure to known gas concentrations. For environmental monitoring, the selected carbon dioxide sensors were characterized around 400 ppm. For methane, the sensor response was first monitored at 0 ppm, close to the typical environmental background. The selected sensors were then evaluated at gas concentrations of several thousand ppm. The determined detection limits accuracy, and precision provides a set of matrices that can be used to evaluate and select sensors for integration into a sensor platform for specific applications. MDPI 2019-07-18 /pmc/articles/PMC6679274/ /pubmed/31323772 http://dx.doi.org/10.3390/s19143157 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Honeycutt, Wesley T. Ley, M. Tyler Materer, Nicholas F. Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors |
title | Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors |
title_full | Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors |
title_fullStr | Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors |
title_full_unstemmed | Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors |
title_short | Precision and Limits of Detection for Selected Commercially Available, Low-Cost Carbon Dioxide and Methane Gas Sensors |
title_sort | precision and limits of detection for selected commercially available, low-cost carbon dioxide and methane gas sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679274/ https://www.ncbi.nlm.nih.gov/pubmed/31323772 http://dx.doi.org/10.3390/s19143157 |
work_keys_str_mv | AT honeycuttwesleyt precisionandlimitsofdetectionforselectedcommerciallyavailablelowcostcarbondioxideandmethanegassensors AT leymtyler precisionandlimitsofdetectionforselectedcommerciallyavailablelowcostcarbondioxideandmethanegassensors AT materernicholasf precisionandlimitsofdetectionforselectedcommerciallyavailablelowcostcarbondioxideandmethanegassensors |