Cargando…

A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption

A photoacoustic spectroscopy (PAS)-based carbon monoxide (CO) gas sensor with a high-power laser and an enhanced gas absorption was demonstrated. The light source was a distributed feedback (DFB), continuous wave (CW) diode laser with a high output power of ~8 mW to give a strong excitation. The tar...

Descripción completa

Detalles Bibliográficos
Autores principales: Qiao, Shunda, Ma, Yufei, He, Ying, Yu, Xin, Zhang, Zhonghua, Tittel, Frank K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679288/
https://www.ncbi.nlm.nih.gov/pubmed/31330789
http://dx.doi.org/10.3390/s19143202
_version_ 1783441304036835328
author Qiao, Shunda
Ma, Yufei
He, Ying
Yu, Xin
Zhang, Zhonghua
Tittel, Frank K.
author_facet Qiao, Shunda
Ma, Yufei
He, Ying
Yu, Xin
Zhang, Zhonghua
Tittel, Frank K.
author_sort Qiao, Shunda
collection PubMed
description A photoacoustic spectroscopy (PAS)-based carbon monoxide (CO) gas sensor with a high-power laser and an enhanced gas absorption was demonstrated. The light source was a distributed feedback (DFB), continuous wave (CW) diode laser with a high output power of ~8 mW to give a strong excitation. The target gas received optical absorption enhanced two times by using a right-angle prism reflecting the laser beam. In order to reduce the noise from the background, wavelength modulation spectroscopy (WMS) and second-harmonic detection techniques were used. The modulation frequency and modulation depth were optimized theoretically and experimentally. Water vapor was added in the PAS sensor system to increase the vibrational–translational (V–T) relaxation rate of the CO molecule, which resulted in an ~8 times signal enhancement compared with the using of a dry CO/N(2) gas mixture. The amplitude of the 2f signal had a 1.52-fold improvement compared to the one with only one time absorption. The experimental results showed that such a sensor had an excellent linear response to the optical power and gas concentration. At 1 s integration time, a minimum detection limit (MDL) for CO detection of 9.8 ppm was achieved. The long-term stability of the sensor system was evaluated with an Allan deviation analysis. When the integration time was 1100 s, the MDL improved to be 530 ppb. The detection performance of such a PAS-based CO sensor can be further improved when a laser with a higher output power and increasing optical absorption times is used.
format Online
Article
Text
id pubmed-6679288
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66792882019-08-19 A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption Qiao, Shunda Ma, Yufei He, Ying Yu, Xin Zhang, Zhonghua Tittel, Frank K. Sensors (Basel) Article A photoacoustic spectroscopy (PAS)-based carbon monoxide (CO) gas sensor with a high-power laser and an enhanced gas absorption was demonstrated. The light source was a distributed feedback (DFB), continuous wave (CW) diode laser with a high output power of ~8 mW to give a strong excitation. The target gas received optical absorption enhanced two times by using a right-angle prism reflecting the laser beam. In order to reduce the noise from the background, wavelength modulation spectroscopy (WMS) and second-harmonic detection techniques were used. The modulation frequency and modulation depth were optimized theoretically and experimentally. Water vapor was added in the PAS sensor system to increase the vibrational–translational (V–T) relaxation rate of the CO molecule, which resulted in an ~8 times signal enhancement compared with the using of a dry CO/N(2) gas mixture. The amplitude of the 2f signal had a 1.52-fold improvement compared to the one with only one time absorption. The experimental results showed that such a sensor had an excellent linear response to the optical power and gas concentration. At 1 s integration time, a minimum detection limit (MDL) for CO detection of 9.8 ppm was achieved. The long-term stability of the sensor system was evaluated with an Allan deviation analysis. When the integration time was 1100 s, the MDL improved to be 530 ppb. The detection performance of such a PAS-based CO sensor can be further improved when a laser with a higher output power and increasing optical absorption times is used. MDPI 2019-07-20 /pmc/articles/PMC6679288/ /pubmed/31330789 http://dx.doi.org/10.3390/s19143202 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Qiao, Shunda
Ma, Yufei
He, Ying
Yu, Xin
Zhang, Zhonghua
Tittel, Frank K.
A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption
title A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption
title_full A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption
title_fullStr A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption
title_full_unstemmed A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption
title_short A Sensitive Carbon Monoxide Sensor Based on Photoacoustic Spectroscopy with a 2.3 μm Mid-Infrared High-Power Laser and Enhanced Gas Absorption
title_sort sensitive carbon monoxide sensor based on photoacoustic spectroscopy with a 2.3 μm mid-infrared high-power laser and enhanced gas absorption
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679288/
https://www.ncbi.nlm.nih.gov/pubmed/31330789
http://dx.doi.org/10.3390/s19143202
work_keys_str_mv AT qiaoshunda asensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT mayufei asensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT heying asensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT yuxin asensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT zhangzhonghua asensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT tittelfrankk asensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT qiaoshunda sensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT mayufei sensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT heying sensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT yuxin sensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT zhangzhonghua sensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption
AT tittelfrankk sensitivecarbonmonoxidesensorbasedonphotoacousticspectroscopywitha23mmmidinfraredhighpowerlaserandenhancedgasabsorption