Cargando…
Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting
BACKGROUND: Anesthesia providers may need to interpret the output of vital sign monitors based on auditory cues, in the context of multitasking in the operating room. This study aims to evaluate the ability of different anesthesia providers to estimate heart rate and oxygen saturation in a simulatio...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679872/ https://www.ncbi.nlm.nih.gov/pubmed/31428146 http://dx.doi.org/10.1155/2019/5914305 |
_version_ | 1783441406203789312 |
---|---|
author | Riveros Perez, Efrain Jimenez, Enoe Albo, Camila Sanghvi, Yashi Yang, Nianlan Rocuts, Alexander |
author_facet | Riveros Perez, Efrain Jimenez, Enoe Albo, Camila Sanghvi, Yashi Yang, Nianlan Rocuts, Alexander |
author_sort | Riveros Perez, Efrain |
collection | PubMed |
description | BACKGROUND: Anesthesia providers may need to interpret the output of vital sign monitors based on auditory cues, in the context of multitasking in the operating room. This study aims to evaluate the ability of different anesthesia providers to estimate heart rate and oxygen saturation in a simulation setting. METHODS: Sixty anesthesia providers (residents, nurse anesthetics, and anesthesiologists) were studied. Four scenarios were arranged in a simulation context. Two baseline scenarios with and without waveform visual aid, and two scenarios with variation of heart rate and/or oxygen saturation were used to assess the accuracy of the estimation made by the participants. RESULTS: When the accurate threshold for the heart rate was set at less than 5 beats per minute, the providers only had a correct estimation at two baseline settings with visual aids (p=0.22 and 0.2237). Anesthesia providers tend to underestimate the heart rate when it increases. Providers failed to accurately estimate oxygen saturation with or without visual aid (p=0.0276 and 0.0105, respectively). Change in recording settings significantly affected the accuracy of heart rate estimation (p < 0.0001), and different experience levels affected the estimation accuracy (p=0.041). CONCLUSION: The ability of anesthesia providers with different levels of experience to assess baseline and variations of heart rate and oxygen saturation is unsatisfactory, especially when oxygen desaturation and bradycardia coexist, and when the subject has less years of experience. |
format | Online Article Text |
id | pubmed-6679872 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-66798722019-08-19 Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting Riveros Perez, Efrain Jimenez, Enoe Albo, Camila Sanghvi, Yashi Yang, Nianlan Rocuts, Alexander Anesthesiol Res Pract Research Article BACKGROUND: Anesthesia providers may need to interpret the output of vital sign monitors based on auditory cues, in the context of multitasking in the operating room. This study aims to evaluate the ability of different anesthesia providers to estimate heart rate and oxygen saturation in a simulation setting. METHODS: Sixty anesthesia providers (residents, nurse anesthetics, and anesthesiologists) were studied. Four scenarios were arranged in a simulation context. Two baseline scenarios with and without waveform visual aid, and two scenarios with variation of heart rate and/or oxygen saturation were used to assess the accuracy of the estimation made by the participants. RESULTS: When the accurate threshold for the heart rate was set at less than 5 beats per minute, the providers only had a correct estimation at two baseline settings with visual aids (p=0.22 and 0.2237). Anesthesia providers tend to underestimate the heart rate when it increases. Providers failed to accurately estimate oxygen saturation with or without visual aid (p=0.0276 and 0.0105, respectively). Change in recording settings significantly affected the accuracy of heart rate estimation (p < 0.0001), and different experience levels affected the estimation accuracy (p=0.041). CONCLUSION: The ability of anesthesia providers with different levels of experience to assess baseline and variations of heart rate and oxygen saturation is unsatisfactory, especially when oxygen desaturation and bradycardia coexist, and when the subject has less years of experience. Hindawi 2019-07-21 /pmc/articles/PMC6679872/ /pubmed/31428146 http://dx.doi.org/10.1155/2019/5914305 Text en Copyright © 2019 Efrain Riveros Perez et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Riveros Perez, Efrain Jimenez, Enoe Albo, Camila Sanghvi, Yashi Yang, Nianlan Rocuts, Alexander Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting |
title | Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting |
title_full | Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting |
title_fullStr | Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting |
title_full_unstemmed | Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting |
title_short | Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting |
title_sort | are anesthesiology providers good guessers? heart rate and oxygen saturation estimation in a simulation setting |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679872/ https://www.ncbi.nlm.nih.gov/pubmed/31428146 http://dx.doi.org/10.1155/2019/5914305 |
work_keys_str_mv | AT riverosperezefrain areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting AT jimenezenoe areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting AT albocamila areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting AT sanghviyashi areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting AT yangnianlan areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting AT rocutsalexander areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting |