Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting

BACKGROUND: Anesthesia providers may need to interpret the output of vital sign monitors based on auditory cues, in the context of multitasking in the operating room. This study aims to evaluate the ability of different anesthesia providers to estimate heart rate and oxygen saturation in a simulatio...

Descripción completa

Detalles Bibliográficos
Autores principales: Riveros Perez, Efrain, Jimenez, Enoe, Albo, Camila, Sanghvi, Yashi, Yang, Nianlan, Rocuts, Alexander
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679872/
https://www.ncbi.nlm.nih.gov/pubmed/31428146
http://dx.doi.org/10.1155/2019/5914305
_version_ 1783441406203789312
author Riveros Perez, Efrain
Jimenez, Enoe
Albo, Camila
Sanghvi, Yashi
Yang, Nianlan
Rocuts, Alexander
author_facet Riveros Perez, Efrain
Jimenez, Enoe
Albo, Camila
Sanghvi, Yashi
Yang, Nianlan
Rocuts, Alexander
author_sort Riveros Perez, Efrain
collection PubMed
description BACKGROUND: Anesthesia providers may need to interpret the output of vital sign monitors based on auditory cues, in the context of multitasking in the operating room. This study aims to evaluate the ability of different anesthesia providers to estimate heart rate and oxygen saturation in a simulation setting. METHODS: Sixty anesthesia providers (residents, nurse anesthetics, and anesthesiologists) were studied. Four scenarios were arranged in a simulation context. Two baseline scenarios with and without waveform visual aid, and two scenarios with variation of heart rate and/or oxygen saturation were used to assess the accuracy of the estimation made by the participants. RESULTS: When the accurate threshold for the heart rate was set at less than 5 beats per minute, the providers only had a correct estimation at two baseline settings with visual aids (p=0.22 and 0.2237). Anesthesia providers tend to underestimate the heart rate when it increases. Providers failed to accurately estimate oxygen saturation with or without visual aid (p=0.0276 and 0.0105, respectively). Change in recording settings significantly affected the accuracy of heart rate estimation (p < 0.0001), and different experience levels affected the estimation accuracy (p=0.041). CONCLUSION: The ability of anesthesia providers with different levels of experience to assess baseline and variations of heart rate and oxygen saturation is unsatisfactory, especially when oxygen desaturation and bradycardia coexist, and when the subject has less years of experience.
format Online
Article
Text
id pubmed-6679872
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-66798722019-08-19 Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting Riveros Perez, Efrain Jimenez, Enoe Albo, Camila Sanghvi, Yashi Yang, Nianlan Rocuts, Alexander Anesthesiol Res Pract Research Article BACKGROUND: Anesthesia providers may need to interpret the output of vital sign monitors based on auditory cues, in the context of multitasking in the operating room. This study aims to evaluate the ability of different anesthesia providers to estimate heart rate and oxygen saturation in a simulation setting. METHODS: Sixty anesthesia providers (residents, nurse anesthetics, and anesthesiologists) were studied. Four scenarios were arranged in a simulation context. Two baseline scenarios with and without waveform visual aid, and two scenarios with variation of heart rate and/or oxygen saturation were used to assess the accuracy of the estimation made by the participants. RESULTS: When the accurate threshold for the heart rate was set at less than 5 beats per minute, the providers only had a correct estimation at two baseline settings with visual aids (p=0.22 and 0.2237). Anesthesia providers tend to underestimate the heart rate when it increases. Providers failed to accurately estimate oxygen saturation with or without visual aid (p=0.0276 and 0.0105, respectively). Change in recording settings significantly affected the accuracy of heart rate estimation (p < 0.0001), and different experience levels affected the estimation accuracy (p=0.041). CONCLUSION: The ability of anesthesia providers with different levels of experience to assess baseline and variations of heart rate and oxygen saturation is unsatisfactory, especially when oxygen desaturation and bradycardia coexist, and when the subject has less years of experience. Hindawi 2019-07-21 /pmc/articles/PMC6679872/ /pubmed/31428146 http://dx.doi.org/10.1155/2019/5914305 Text en Copyright © 2019 Efrain Riveros Perez et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Riveros Perez, Efrain
Jimenez, Enoe
Albo, Camila
Sanghvi, Yashi
Yang, Nianlan
Rocuts, Alexander
Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting
title Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting
title_full Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting
title_fullStr Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting
title_full_unstemmed Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting
title_short Are Anesthesiology Providers Good Guessers? Heart Rate and Oxygen Saturation Estimation in a Simulation Setting
title_sort are anesthesiology providers good guessers? heart rate and oxygen saturation estimation in a simulation setting
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6679872/
https://www.ncbi.nlm.nih.gov/pubmed/31428146
http://dx.doi.org/10.1155/2019/5914305
work_keys_str_mv AT riverosperezefrain areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting
AT jimenezenoe areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting
AT albocamila areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting
AT sanghviyashi areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting
AT yangnianlan areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting
AT rocutsalexander areanesthesiologyprovidersgoodguessersheartrateandoxygensaturationestimationinasimulationsetting