Cargando…

A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design

BACKGROUND/AIMS: We applied a back light system (BLS) with a magnifying glass to improve the ability to assess the adequacy of specimen sampling using endosonography. We conducted this study to evaluate the efficacy of the BLS in sampling of specimens by endoscopic ultrasound-guided fine needle aspi...

Descripción completa

Detalles Bibliográficos
Autores principales: Harada, Ryo, Kato, Hironari, Fushimi, Soichiro, Inoue, Hirofumi, Uchida, Daisuke, Akimoto, Yutaka, Tomoda, Takeshi, Matsumoto, Kazuyuki, Noma, Yasuhiro, Yamamoto, Naoki, Horiguchi, Shigeru, Tsutsumi, Koichiro, Okada, Hiroyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Gastrointestinal Endoscopy 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6680017/
https://www.ncbi.nlm.nih.gov/pubmed/31091869
http://dx.doi.org/10.5946/ce.2019.004
_version_ 1783441420470714368
author Harada, Ryo
Kato, Hironari
Fushimi, Soichiro
Inoue, Hirofumi
Uchida, Daisuke
Akimoto, Yutaka
Tomoda, Takeshi
Matsumoto, Kazuyuki
Noma, Yasuhiro
Yamamoto, Naoki
Horiguchi, Shigeru
Tsutsumi, Koichiro
Okada, Hiroyuki
author_facet Harada, Ryo
Kato, Hironari
Fushimi, Soichiro
Inoue, Hirofumi
Uchida, Daisuke
Akimoto, Yutaka
Tomoda, Takeshi
Matsumoto, Kazuyuki
Noma, Yasuhiro
Yamamoto, Naoki
Horiguchi, Shigeru
Tsutsumi, Koichiro
Okada, Hiroyuki
author_sort Harada, Ryo
collection PubMed
description BACKGROUND/AIMS: We applied a back light system (BLS) with a magnifying glass to improve the ability to assess the adequacy of specimen sampling using endosonography. We conducted this study to evaluate the efficacy of the BLS in sampling of specimens by endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses. METHODS: This was a prospective, randomized, crossover, single-center clinical trial. An endosonographer evaluated adequacy on gross visual inspection and identified whitish specimen sampling sites with and without the BLS according to a randomization sequence in the first and second passes with a 25-G needle. On cytological evaluation, the presence of well-defined pancreatic ductal epithelium was evaluated by a cytopathologist who was blinded to any clinical information. RESULTS: A total of 80 consecutive patients were eligible during the study period. Adequacy was observed for 52 specimens (65%) with the BLS and 54 (68%) without the BLS (p=0.88). In assessment of specimen adequacy on gross examination, only fair agreement was observed both with and without BLS (kappa score 0.40 and 0.29, respectively). CONCLUSIONS: The BLS did not influence the ability to identify specimen sampling sites or reliable assessment of specimen site adequacy using gross visual inspection.
format Online
Article
Text
id pubmed-6680017
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Korean Society of Gastrointestinal Endoscopy
record_format MEDLINE/PubMed
spelling pubmed-66800172019-08-05 A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design Harada, Ryo Kato, Hironari Fushimi, Soichiro Inoue, Hirofumi Uchida, Daisuke Akimoto, Yutaka Tomoda, Takeshi Matsumoto, Kazuyuki Noma, Yasuhiro Yamamoto, Naoki Horiguchi, Shigeru Tsutsumi, Koichiro Okada, Hiroyuki Clin Endosc Original Article BACKGROUND/AIMS: We applied a back light system (BLS) with a magnifying glass to improve the ability to assess the adequacy of specimen sampling using endosonography. We conducted this study to evaluate the efficacy of the BLS in sampling of specimens by endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses. METHODS: This was a prospective, randomized, crossover, single-center clinical trial. An endosonographer evaluated adequacy on gross visual inspection and identified whitish specimen sampling sites with and without the BLS according to a randomization sequence in the first and second passes with a 25-G needle. On cytological evaluation, the presence of well-defined pancreatic ductal epithelium was evaluated by a cytopathologist who was blinded to any clinical information. RESULTS: A total of 80 consecutive patients were eligible during the study period. Adequacy was observed for 52 specimens (65%) with the BLS and 54 (68%) without the BLS (p=0.88). In assessment of specimen adequacy on gross examination, only fair agreement was observed both with and without BLS (kappa score 0.40 and 0.29, respectively). CONCLUSIONS: The BLS did not influence the ability to identify specimen sampling sites or reliable assessment of specimen site adequacy using gross visual inspection. Korean Society of Gastrointestinal Endoscopy 2019-07 2019-05-16 /pmc/articles/PMC6680017/ /pubmed/31091869 http://dx.doi.org/10.5946/ce.2019.004 Text en Copyright © 2019 Korean Society of Gastrointestinal Endoscopy This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Harada, Ryo
Kato, Hironari
Fushimi, Soichiro
Inoue, Hirofumi
Uchida, Daisuke
Akimoto, Yutaka
Tomoda, Takeshi
Matsumoto, Kazuyuki
Noma, Yasuhiro
Yamamoto, Naoki
Horiguchi, Shigeru
Tsutsumi, Koichiro
Okada, Hiroyuki
A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
title A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
title_full A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
title_fullStr A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
title_full_unstemmed A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
title_short A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
title_sort “back light system” for identification of sites for endoscopic ultrasound-guided fine-needle aspiration in solid pancreatic masses: a prospective, randomized study with a crossover design
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6680017/
https://www.ncbi.nlm.nih.gov/pubmed/31091869
http://dx.doi.org/10.5946/ce.2019.004
work_keys_str_mv AT haradaryo abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT katohironari abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT fushimisoichiro abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT inouehirofumi abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT uchidadaisuke abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT akimotoyutaka abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT tomodatakeshi abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT matsumotokazuyuki abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT nomayasuhiro abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT yamamotonaoki abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT horiguchishigeru abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT tsutsumikoichiro abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT okadahiroyuki abacklightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT haradaryo backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT katohironari backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT fushimisoichiro backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT inouehirofumi backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT uchidadaisuke backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT akimotoyutaka backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT tomodatakeshi backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT matsumotokazuyuki backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT nomayasuhiro backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT yamamotonaoki backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT horiguchishigeru backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT tsutsumikoichiro backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign
AT okadahiroyuki backlightsystemforidentificationofsitesforendoscopicultrasoundguidedfineneedleaspirationinsolidpancreaticmassesaprospectiverandomizedstudywithacrossoverdesign