Cargando…

A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology

PURPOSE: We present and validate a new methodology for analyzing, in an automated and objective fashion, infrared images of the meibomian glands (MG). METHODS: The developed algorithm consists of three main steps: selection of the region of interest, detection of MG, and analysis of MG morphometric...

Descripción completa

Detalles Bibliográficos
Autores principales: Llorens-Quintana, Clara, Rico-del-Viejo, Laura, Syga, Piotr, Madrid-Costa, David, Iskander, D. Robert
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6681863/
https://www.ncbi.nlm.nih.gov/pubmed/31392084
http://dx.doi.org/10.1167/tvst.8.4.17
_version_ 1783441785869041664
author Llorens-Quintana, Clara
Rico-del-Viejo, Laura
Syga, Piotr
Madrid-Costa, David
Iskander, D. Robert
author_facet Llorens-Quintana, Clara
Rico-del-Viejo, Laura
Syga, Piotr
Madrid-Costa, David
Iskander, D. Robert
author_sort Llorens-Quintana, Clara
collection PubMed
description PURPOSE: We present and validate a new methodology for analyzing, in an automated and objective fashion, infrared images of the meibomian glands (MG). METHODS: The developed algorithm consists of three main steps: selection of the region of interest, detection of MG, and analysis of MG morphometric parameters and dropout area (DOA). Additionally, a new approach to quantify the irregularity of MG is introduced. We recruited 149 adults from a general population. Infrared meibography, using Keratograph 5M, was performed. Images were assessed and graded subjectively (Meiboscore) by two experienced clinicians and objectively with the proposed automated method. RESULTS: The correlation of subjective DOA assessment between the two clinicians was poor and the average percentage of DOA estimated objectively for each Meiboscore group did not lie within their limits. The objective assessment showed lower variability of meibography grading than that obtained subjectively. Additionally, a new grading scale of MG DOA that reduces intraclass variation is proposed. Reported values of MG length and width were inversely proportional to the DOA. Gland irregularity was objectively quantified. CONCLUSIONS: The proposed automatic and objective method provides accurate estimates of the DOA as well as additional morphologic parameters that could add valuable information in MG dysfunction understanding and diagnosis. TRANSLATIONAL RELEVANCE: This approach highlights the shortcomings of currently used subjective methods, and provides the clinicians with an objective, quantitative and less variable alternative for assessing MG in a noninvasive and automated fashion. It provides a viable alternative to more time-consuming subjective methods.
format Online
Article
Text
id pubmed-6681863
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-66818632019-08-07 A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology Llorens-Quintana, Clara Rico-del-Viejo, Laura Syga, Piotr Madrid-Costa, David Iskander, D. Robert Transl Vis Sci Technol Articles PURPOSE: We present and validate a new methodology for analyzing, in an automated and objective fashion, infrared images of the meibomian glands (MG). METHODS: The developed algorithm consists of three main steps: selection of the region of interest, detection of MG, and analysis of MG morphometric parameters and dropout area (DOA). Additionally, a new approach to quantify the irregularity of MG is introduced. We recruited 149 adults from a general population. Infrared meibography, using Keratograph 5M, was performed. Images were assessed and graded subjectively (Meiboscore) by two experienced clinicians and objectively with the proposed automated method. RESULTS: The correlation of subjective DOA assessment between the two clinicians was poor and the average percentage of DOA estimated objectively for each Meiboscore group did not lie within their limits. The objective assessment showed lower variability of meibography grading than that obtained subjectively. Additionally, a new grading scale of MG DOA that reduces intraclass variation is proposed. Reported values of MG length and width were inversely proportional to the DOA. Gland irregularity was objectively quantified. CONCLUSIONS: The proposed automatic and objective method provides accurate estimates of the DOA as well as additional morphologic parameters that could add valuable information in MG dysfunction understanding and diagnosis. TRANSLATIONAL RELEVANCE: This approach highlights the shortcomings of currently used subjective methods, and provides the clinicians with an objective, quantitative and less variable alternative for assessing MG in a noninvasive and automated fashion. It provides a viable alternative to more time-consuming subjective methods. The Association for Research in Vision and Ophthalmology 2019-08-02 /pmc/articles/PMC6681863/ /pubmed/31392084 http://dx.doi.org/10.1167/tvst.8.4.17 Text en Copyright 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Articles
Llorens-Quintana, Clara
Rico-del-Viejo, Laura
Syga, Piotr
Madrid-Costa, David
Iskander, D. Robert
A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology
title A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology
title_full A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology
title_fullStr A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology
title_full_unstemmed A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology
title_short A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology
title_sort novel automated approach for infrared-based assessment of meibomian gland morphology
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6681863/
https://www.ncbi.nlm.nih.gov/pubmed/31392084
http://dx.doi.org/10.1167/tvst.8.4.17
work_keys_str_mv AT llorensquintanaclara anovelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT ricodelviejolaura anovelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT sygapiotr anovelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT madridcostadavid anovelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT iskanderdrobert anovelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT llorensquintanaclara novelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT ricodelviejolaura novelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT sygapiotr novelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT madridcostadavid novelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology
AT iskanderdrobert novelautomatedapproachforinfraredbasedassessmentofmeibomianglandmorphology