Cargando…

Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP

PURPOSE: To investigate the potential of continuous radiofrequency (RF) shifting (SWEEP) as a technique for creating densely sampled data while maintaining a stable signal state for dynamic imaging. METHODS: We present a method where a continuous stable state of magnetization is swept smoothly acros...

Descripción completa

Detalles Bibliográficos
Autores principales: Jackson, L. H., Price, A. N., Hutter, J., Ho, A., Roberts, T. A., Slator, P. J., Clough, J. R., Deprez, M., McCabe, L., Malik, S. J., Chappell, L., Rutherford, M. A., Hajnal, J. V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6682494/
https://www.ncbi.nlm.nih.gov/pubmed/31183892
http://dx.doi.org/10.1002/mrm.27834
_version_ 1783441892699013120
author Jackson, L. H.
Price, A. N.
Hutter, J.
Ho, A.
Roberts, T. A.
Slator, P. J.
Clough, J. R.
Deprez, M.
McCabe, L.
Malik, S. J.
Chappell, L.
Rutherford, M. A.
Hajnal, J. V.
author_facet Jackson, L. H.
Price, A. N.
Hutter, J.
Ho, A.
Roberts, T. A.
Slator, P. J.
Clough, J. R.
Deprez, M.
McCabe, L.
Malik, S. J.
Chappell, L.
Rutherford, M. A.
Hajnal, J. V.
author_sort Jackson, L. H.
collection PubMed
description PURPOSE: To investigate the potential of continuous radiofrequency (RF) shifting (SWEEP) as a technique for creating densely sampled data while maintaining a stable signal state for dynamic imaging. METHODS: We present a method where a continuous stable state of magnetization is swept smoothly across the anatomy of interest, creating an efficient approach to dense multiple 2D slice imaging. This is achieved by introducing a linear frequency offset to successive RF pulses shifting the excited slice by a fraction of the slice thickness with each successive repeat times (TR). Simulations and in vivo imaging were performed to assess how this affects the measured signal. Free breathing, respiration resolved 4D volumes in fetal/placental imaging is explored as potential application of this method. RESULTS: The SWEEP method maintained a stable signal state over a full acquisition reducing artifacts from unstable magnetization. Simulations demonstrated that the effects of SWEEP on slice profiles was of the same order as that produced by physiological motion observed with conventional methods. Respiration resolved 4D data acquired with this method shows reduced respiration artifacts and resilience to non‐rigid and non‐cyclic motion. CONCLUSIONS: The SWEEP method is presented as a technique for improved acquisition efficiency of densely sampled short‐TR 2D sequences. Using conventional slice excitation the number of RF pulses required to enter a true steady state is excessively high when using short‐TR 2D acquisitions, SWEEP circumvents this limitation by creating a stable signal state that is preserved between slices.
format Online
Article
Text
id pubmed-6682494
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-66824942019-10-07 Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP Jackson, L. H. Price, A. N. Hutter, J. Ho, A. Roberts, T. A. Slator, P. J. Clough, J. R. Deprez, M. McCabe, L. Malik, S. J. Chappell, L. Rutherford, M. A. Hajnal, J. V. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: To investigate the potential of continuous radiofrequency (RF) shifting (SWEEP) as a technique for creating densely sampled data while maintaining a stable signal state for dynamic imaging. METHODS: We present a method where a continuous stable state of magnetization is swept smoothly across the anatomy of interest, creating an efficient approach to dense multiple 2D slice imaging. This is achieved by introducing a linear frequency offset to successive RF pulses shifting the excited slice by a fraction of the slice thickness with each successive repeat times (TR). Simulations and in vivo imaging were performed to assess how this affects the measured signal. Free breathing, respiration resolved 4D volumes in fetal/placental imaging is explored as potential application of this method. RESULTS: The SWEEP method maintained a stable signal state over a full acquisition reducing artifacts from unstable magnetization. Simulations demonstrated that the effects of SWEEP on slice profiles was of the same order as that produced by physiological motion observed with conventional methods. Respiration resolved 4D data acquired with this method shows reduced respiration artifacts and resilience to non‐rigid and non‐cyclic motion. CONCLUSIONS: The SWEEP method is presented as a technique for improved acquisition efficiency of densely sampled short‐TR 2D sequences. Using conventional slice excitation the number of RF pulses required to enter a true steady state is excessively high when using short‐TR 2D acquisitions, SWEEP circumvents this limitation by creating a stable signal state that is preserved between slices. John Wiley and Sons Inc. 2019-06-10 2019-11 /pmc/articles/PMC6682494/ /pubmed/31183892 http://dx.doi.org/10.1002/mrm.27834 Text en © 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Imaging Methodology
Jackson, L. H.
Price, A. N.
Hutter, J.
Ho, A.
Roberts, T. A.
Slator, P. J.
Clough, J. R.
Deprez, M.
McCabe, L.
Malik, S. J.
Chappell, L.
Rutherford, M. A.
Hajnal, J. V.
Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP
title Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP
title_full Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP
title_fullStr Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP
title_full_unstemmed Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP
title_short Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP
title_sort respiration resolved imaging with continuous stable state 2d acquisition using linear frequency sweep
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6682494/
https://www.ncbi.nlm.nih.gov/pubmed/31183892
http://dx.doi.org/10.1002/mrm.27834
work_keys_str_mv AT jacksonlh respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT pricean respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT hutterj respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT hoa respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT robertsta respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT slatorpj respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT cloughjr respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT deprezm respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT mccabel respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT maliksj respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT chappelll respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT rutherfordma respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep
AT hajnaljv respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep