Cargando…
Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP
PURPOSE: To investigate the potential of continuous radiofrequency (RF) shifting (SWEEP) as a technique for creating densely sampled data while maintaining a stable signal state for dynamic imaging. METHODS: We present a method where a continuous stable state of magnetization is swept smoothly acros...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6682494/ https://www.ncbi.nlm.nih.gov/pubmed/31183892 http://dx.doi.org/10.1002/mrm.27834 |
_version_ | 1783441892699013120 |
---|---|
author | Jackson, L. H. Price, A. N. Hutter, J. Ho, A. Roberts, T. A. Slator, P. J. Clough, J. R. Deprez, M. McCabe, L. Malik, S. J. Chappell, L. Rutherford, M. A. Hajnal, J. V. |
author_facet | Jackson, L. H. Price, A. N. Hutter, J. Ho, A. Roberts, T. A. Slator, P. J. Clough, J. R. Deprez, M. McCabe, L. Malik, S. J. Chappell, L. Rutherford, M. A. Hajnal, J. V. |
author_sort | Jackson, L. H. |
collection | PubMed |
description | PURPOSE: To investigate the potential of continuous radiofrequency (RF) shifting (SWEEP) as a technique for creating densely sampled data while maintaining a stable signal state for dynamic imaging. METHODS: We present a method where a continuous stable state of magnetization is swept smoothly across the anatomy of interest, creating an efficient approach to dense multiple 2D slice imaging. This is achieved by introducing a linear frequency offset to successive RF pulses shifting the excited slice by a fraction of the slice thickness with each successive repeat times (TR). Simulations and in vivo imaging were performed to assess how this affects the measured signal. Free breathing, respiration resolved 4D volumes in fetal/placental imaging is explored as potential application of this method. RESULTS: The SWEEP method maintained a stable signal state over a full acquisition reducing artifacts from unstable magnetization. Simulations demonstrated that the effects of SWEEP on slice profiles was of the same order as that produced by physiological motion observed with conventional methods. Respiration resolved 4D data acquired with this method shows reduced respiration artifacts and resilience to non‐rigid and non‐cyclic motion. CONCLUSIONS: The SWEEP method is presented as a technique for improved acquisition efficiency of densely sampled short‐TR 2D sequences. Using conventional slice excitation the number of RF pulses required to enter a true steady state is excessively high when using short‐TR 2D acquisitions, SWEEP circumvents this limitation by creating a stable signal state that is preserved between slices. |
format | Online Article Text |
id | pubmed-6682494 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-66824942019-10-07 Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP Jackson, L. H. Price, A. N. Hutter, J. Ho, A. Roberts, T. A. Slator, P. J. Clough, J. R. Deprez, M. McCabe, L. Malik, S. J. Chappell, L. Rutherford, M. A. Hajnal, J. V. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: To investigate the potential of continuous radiofrequency (RF) shifting (SWEEP) as a technique for creating densely sampled data while maintaining a stable signal state for dynamic imaging. METHODS: We present a method where a continuous stable state of magnetization is swept smoothly across the anatomy of interest, creating an efficient approach to dense multiple 2D slice imaging. This is achieved by introducing a linear frequency offset to successive RF pulses shifting the excited slice by a fraction of the slice thickness with each successive repeat times (TR). Simulations and in vivo imaging were performed to assess how this affects the measured signal. Free breathing, respiration resolved 4D volumes in fetal/placental imaging is explored as potential application of this method. RESULTS: The SWEEP method maintained a stable signal state over a full acquisition reducing artifacts from unstable magnetization. Simulations demonstrated that the effects of SWEEP on slice profiles was of the same order as that produced by physiological motion observed with conventional methods. Respiration resolved 4D data acquired with this method shows reduced respiration artifacts and resilience to non‐rigid and non‐cyclic motion. CONCLUSIONS: The SWEEP method is presented as a technique for improved acquisition efficiency of densely sampled short‐TR 2D sequences. Using conventional slice excitation the number of RF pulses required to enter a true steady state is excessively high when using short‐TR 2D acquisitions, SWEEP circumvents this limitation by creating a stable signal state that is preserved between slices. John Wiley and Sons Inc. 2019-06-10 2019-11 /pmc/articles/PMC6682494/ /pubmed/31183892 http://dx.doi.org/10.1002/mrm.27834 Text en © 2019 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Full Papers—Imaging Methodology Jackson, L. H. Price, A. N. Hutter, J. Ho, A. Roberts, T. A. Slator, P. J. Clough, J. R. Deprez, M. McCabe, L. Malik, S. J. Chappell, L. Rutherford, M. A. Hajnal, J. V. Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP |
title | Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP |
title_full | Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP |
title_fullStr | Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP |
title_full_unstemmed | Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP |
title_short | Respiration resolved imaging with continuous stable state 2D acquisition using linear frequency SWEEP |
title_sort | respiration resolved imaging with continuous stable state 2d acquisition using linear frequency sweep |
topic | Full Papers—Imaging Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6682494/ https://www.ncbi.nlm.nih.gov/pubmed/31183892 http://dx.doi.org/10.1002/mrm.27834 |
work_keys_str_mv | AT jacksonlh respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT pricean respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT hutterj respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT hoa respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT robertsta respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT slatorpj respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT cloughjr respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT deprezm respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT mccabel respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT maliksj respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT chappelll respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT rutherfordma respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep AT hajnaljv respirationresolvedimagingwithcontinuousstablestate2dacquisitionusinglinearfrequencysweep |